China Water Meter Ultrasonic Dn15 to Dn20 Water Meter RS485, Find details about China Smart Water Meter, Ultrasonic Water Meter from Water Meter Ultrasonic Dn15 to Dn20 Water Meter RS485
Smart ultrasonic water meter measurement of water consumption in households, apartment buildings and small commercial properties
1. DN15, DN20
2. Communication: M-BUS, RS-485, Pulse output, LoRaWAN, LoRa
3. R400/ R250
TECHNICAL SPECIFICATION:
Item | Parameter |
Meter Type | Ultrasonic Water Meter |
Nominal Diameter (mm) | DN15~DN20 |
Q3/Q1 | R400/ R250 |
Measured medium | Water, homogeneous liquid, and filled with measured pipes. |
Accuracy class | Class 2 |
Water pressure class | 1.6MAP ( 16 bar) |
Pressure-loss class | Δp40 |
Temperature class | T50 |
Installation position | H/V |
The installation sensitivity class | U10/D5 |
Electromagnetic class | E1 |
Environmental class | C |
Key-press | Magnetic induction key |
Types of Indicating device | LCD:9-digits, 0~99999.9999m³ |
Menu Contents | Instantaneous flow (m3/h), cumulative flow (m3), screen detection, table address, cumulative working time (h), date (year/month/day), caliber, software version |
Communication Interface | Photoelectric |
Power Source | Lithium battery ER26500(replaceable) |
Battery Voltage &Capacity | 3.6V , 8500mAh |
Life span | 10 years. |
IP code | IP68 |
Storage Temperature | -25ºC~+55ºC |
Cable length | 1.0 m |
FLOW RATE:
Parameter | Unit | Data value | |
Nominal Diameter |
| DN15 | DN20 |
Start flow rate | m3/h | 0.003 | 0.005 |
Qmin(Q1) | 0.010 | 0.016 | |
QTransitional(Q2) | 0.016 | 0.0256 | |
Qmax/permanent(Q3) | 2.5 | 4.0 | |
Qoverload(Q4) | 3.125 | 5.0 | |
Range ratio=Q3/Q1 |
| 250 | |
Temperature |
| T50 | |
Battery life | Year | >10 |
DIMENSION
Nominal Diameter( mm ) | DN15 | DN20 |
Thread | G3/4B | G1B |
L(mm) | 110 | 130 |
H(mm) | 80 | 80 |
W(mm) | 85 | 85 |
WORKING CONDITION:
Water temperature: 0~50ºC
Water pressure: ≤16 Bar