Voltage Transformer / Potential Transformer for Voltage and Power Measurement

China Voltage Transformer / Potential Transformer for Voltage and Power Measurement, Find details about China Voltage Transformer, Mini Vlotage Transformer from Voltage Transformer / Potential Transformer for Voltage and Power Measurement

Model NO.
ZMPT101K
Insulating Medium
Epoxy Resin
Installation
PCB Mounting
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Capacitive Type
N.W
11.9g
Trademark
zeming
Transport Package
Cartons
Specification
UL, ISO9001, ISO14001, ROHS, CE, SGS
Origin
China
HS Code
8504311000
Model NO.
ZMPT101K
Insulating Medium
Epoxy Resin
Installation
PCB Mounting
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Capacitive Type
N.W
11.9g
Trademark
zeming
Transport Package
Cartons
Specification
UL, ISO9001, ISO14001, ROHS, CE, SGS
Origin
China
HS Code
8504311000
ZMPT101K
Current-type Voltage Transformer

Small size,high accuracy,good consistency,for voltage and power measurement
 
Structural parameters:

Voltage Transformer / Potential Transformer for Voltage and Power Measurement
 
                               Remarks: primary input: 1,2 pins  secondary output: 3,4pins
                                                      Or
                                        primary input:: 3,4 pins  secondary output::1,2pins
             Front view                                                                        Bottom view

 
The main technical parameters:
ModelZMPT101K
Rated input current2mA
Rated output current2mA
turns ratio1000:1000
phase angle error≤20'(input 2mA,sampling resistor 100Ω)
linear range0~1000V       0~10mA(sampling resistor 100Ω)
linearity≤0.2%(20%dot~120%dot)
Permissible error-0.3%≤ f ≤+0.2%(input 2mA,sampling resistor 100Ω)
isolation voltage4000V
applicationvoltage and power measurement
EncapsulationEpoxy
installationPCB mounting(Pin Length>3mm)
Operating temperature-40ºC~+85ºC
 
Direction for use:

Voltage Transformer / Potential Transformer for Voltage and Power Measurement
1. The typical usage of the product is for the active output (Figure). R'is a limiting resistor,R is a sampling resistor.
2. The product can be directly through the resistance sampling , easy to use ( Figure).


Voltage Transformer / Potential Transformer for Voltage and Power Measurement


Voltage Transformer / Potential Transformer for Voltage and Power Measurement
Voltage Transformer / Potential Transformer for Voltage and Power Measurement
Voltage Transformer / Potential Transformer for Voltage and Power Measurement
Voltage Transformer / Potential Transformer for Voltage and Power Measurement

Voltage Transformer / Potential Transformer for Voltage and Power MeasurementVoltage Transformer / Potential Transformer for Voltage and Power MeasurementVoltage Transformer / Potential Transformer for Voltage and Power MeasurementVoltage Transformer / Potential Transformer for Voltage and Power Measurement