China Outdoor Waterproof 11kv 800kVA Oil Immersed Power Transformer, Find details about China Power Transformer, Oil Immersed Transformer from Outdoor Waterproof 11kv 800kVA Oil Immersed Power Transformer
Transformer normal service conditions
The height above the sea level is below 1000m;
Highest air temperature +40ºC;
Highest daily average air temperature+30ºC;
Highest annual average air temperature +20ºC;
Lowest outdoor air temperature -25ºC.
(defines in detail when transformer in special service conditions )
10/0.4kV Oil-immersed transformer Technical parameters(Second level of energy efficiency)
Rated capacity (kVA) | Voltage combination | Conn-ected group label | No-load loss (W) | Load loss (75°C)(W) | No-load current(%) | Impedance voltage (%) | Exterior size (L x w x h) | Total weight (kg) | ||
High voltage(kV) | tap range | Low Voltage (kV) | ||||||||
30 | 6 6.3 6.6 10 10.5 11 | ±2x2.5 ±5 | 0.4 | Dyn11 YynO Yzn11 | 80 | 630/600 | 1.5 | 4 | 800 x 500 x 850 | 350 |
50 | 100 | 910/870 | 1.3 | 820 x 550 x 850 | 400 | |||||
63 | 110 | 1090/1040 | 1.2 | 835 x 580 x 850 | 430 | |||||
80 | 130 | 1310/1250 | 1.2 | 840 x 600 x 880 | 450 | |||||
100 | 150 | 1580/1500 | 1.1 | 860 x 600 x 890 | 490 | |||||
125 | 170 | 1890/1800 | 1.1 | 1020x660x900 | 610 | |||||
160 | 200 | 2310/2200 | 1.0 | 1035x660x950 | 670 | |||||
200 | 240 | 2730/2600 | 1.0 | 1040x680x980 | 730 | |||||
250 | 290 | 3200/3050 | 0.9 | 1140x740x1010 | 850 | |||||
315 | 340 | 3830/3650 | 0.9 | 1160x760x1150 | 970 | |||||
400 | 410 | 4520/4300 | 0.8 | 1230x800x1210 | 1130 | |||||
500 | 480 | 5410/5150 | 0.8 | 1320x900x1210 | 1345 | |||||
630 | Dyn11 YynO | 570 | 6200 | 0.6 | 4.5 | 1420x920x1230 | 1630 | |||
800 | 700 | 7500 | 0.6 | 1480x1000x1285 | 1950 | |||||
1000 | 830 | 10300 | 0.6 | 1600x1100x1330 | 2215 | |||||
1250 | 970 | 12000 | 0.5 | 1655x1135x1375 | 2565 | |||||
1600 | 1170 | 14500 | 0.5 | 1815x1260x1450 | 3100 | |||||
2000 | 1550 | 18300 | 0.4 | 5 | 1920x1305x1510 | 3785 | ||||
2500 | 1830 | 21200 | 0.4 | 2120x1430x1575 | 4570 |
Note: 1, To transformers whose rated capacity of 500kVA and below, load loss in the table above the diagonalis suitable for Dyn11 or Yzn11 connection group, | ||||||||||
the load loss below the diagonal suitable for YynO connection group. | ||||||||||
2, according to user needs, can provide transformer with high voltage tap range | ||||||||||
3, according to user needs, can provide transformer with low-voltage of 0.69kV . | ||||||||||
4, if the user needs, can also choose other loss values. | ||||||||||
5, due to the continuous update of the product, weight &size in the table may changes.Most correct Dimension chart will be provied when making order. |