Cu /XLPE/Cts/Lszh/Swa/Lszh, Power Cable, 6.35/11kv, 3/C (BS 7835)

China Cu/XLPE/Cts/Lszh/Swa/Lszh, Power Cable, 6.35/11kv, 3/C (BS 7835), Find details about China Power Cable, XLPE Cable from Cu/XLPE/Cts/Lszh/Swa/Lszh, Power Cable, 6.35/11kv, 3/C (BS 7835)

Model NO.
Cu/XLPE/CTS/LSZH/SWA/LSZH
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE
Model
Cu/XLPE/Cts/Lszh/Swa/Lszh
Brand
Boan
Rated Voltage
6.35/11 Kv
Number of Cores
3
Section
25-300 Mm2
Class of Conductor
2
Metallic Screen
Copper Tape
Type of Armour
Galvanized Steel Wire
Trademark
DingAn
Specification
SGS, CE
Origin
Jiangsu Yixing, China
HS Code
8544601200
Model NO.
Cu/XLPE/CTS/LSZH/SWA/LSZH
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE
Model
Cu/XLPE/Cts/Lszh/Swa/Lszh
Brand
Boan
Rated Voltage
6.35/11 Kv
Number of Cores
3
Section
25-300 Mm2
Class of Conductor
2
Metallic Screen
Copper Tape
Type of Armour
Galvanized Steel Wire
Trademark
DingAn
Specification
SGS, CE
Origin
Jiangsu Yixing, China
HS Code
8544601200
Cu/XLPE/CTS/LSZH/SWA/LSZH, Power Cable, 6.35/11KV, 3/C (BS 7835)
Application
Power cables for power networks, underground, outdoors and in cable ducting. In particular for installation where fire, smoke emission and toxic fumes create a potential threat. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.

Standards
BS7835, IEC 60754-1

Technical Data
Conductor
Class 2 stranded plain copper conductor to BS EN 60228: 2005
(previously BS6360)
Conductor Screen
Semi-conducting material
Insulation
XLPE (Cross-Linked Polyethylene) Type GP8 to BS7655
Insulation Screen
Semi-conducting material
Metallic Screen
Individual and overall copper tape screen to BS6622
Filler
PETP (Polyethylene Terephthalate) fibres
Separator
Binding tape
Bedding
LSZH (Low Smoke Zero Halogen)
Armouring
Single Core: AWA (Aluminium Wire Armoured)
Multi-Core: SWA (Steel Wire Armoured)
Sheath
LSZH (Low Smoke Zero Halogen)

Sheath Colour
Red or Black
Voltage Rating
6350/11000V
Temperature Rating
0 to +90° C
Combustion Characteristics
Oxygen index: 35
Temperature index
280° CHCL emission
0.5% in accordance with BS EN 50267-2-1
Low Smoke classification based on 3 metre cube test
Completed cables comply with the requirements of fire test
BS4066-3 Category 3
Minimum Bending Radius
Three Cores: 12 x overall diameter
No. of Cores x Nominal Cross Sectional AreaNominal DiameterNominal Weight
Under ArmourOver ArmourOverall
# x mm²mmkg/Km
3 x 2539.044.048.84300
3 x 3541.646.651.64700
3 x 5044.449.454.65300
3 x 7048.153.158.56300
3 x 9552.057.062.67300
3 x 12055.660.666.68400
3 x 15058.663.669.89600
3 x 18562.767.774.111000
3 x 24068.174.481.214000
3 x 30073.579.887.016600