High Flow RO Membrane Water Purification 8040

China High Flow RO Membrane Water Purification 8040, Find details about China RO Membrane, Low Pressure Membrane from High Flow RO Membrane Water Purification 8040

Minimum Salt Rejection
99.0
Permeate Flow Rate Gpd
11,500(44)
Maximum Operating Pressure
41 Bar(600 Psi)
Maximum Operating Temperature
1.0 Bar (15 Psi)
Trademark
FROTEC
Transport Package
Carton
Specification
113cm*24cm*25cm
Origin
China
HS Code
8421991000
Minimum Salt Rejection
99.0
Permeate Flow Rate Gpd
11,500(44)
Maximum Operating Pressure
41 Bar(600 Psi)
Maximum Operating Temperature
1.0 Bar (15 Psi)
Trademark
FROTEC
Transport Package
Carton
Specification
113cm*24cm*25cm
Origin
China
HS Code
8421991000

FROTEC BW-8040 / BW-4040 high pressure membrane

FROTEC BW-8040 / BW-4040 elements can separate salts from water and increase permeability while offering superior salt rejection. They are ideal for use in large-scale industrial and municipal water treatment systems.

FROTEC BW-8040 / BW-4040 elements can lower the cost of desalination by improving energy efficiency and productivity significantly.
 

Suitable for:

new-built or existing RO systems.
high quality permeate while minimizing unit cost.
various operating conditions with 4″and 8″elements.


Product Specifications
 
ModelActive Membrane Area
ft2(m2)
Stabilized Salt Rejection
%
Minimum Salt Rejection
%
Permeate Flow
Rate gpd(m3/d)
BW-8040400(37)99.599.010,500(40)
BW-404078(7.2)99.599.02,050(7.8)

Test Condition: Feed Water Pressure 1.55MPa (225 psi); Feed Water Temperature 25 °C (77 °F); Feed Water Concentration 2,000 ppm NaCl; Feed Water pH 7; Permeate Recovery 15%.

Dimensions

High Flow RO Membrane Water Purification 8040
 
ModelA inch(mm)B inch(mm)C inch(mm)D inch(mm)
BW-804040(1,016)01.125(29)7.9(201)
BW-404040(1,016)1.05(26.7)0.75(19)3.9(99)


Operation Condition
Maximum Operating Pressure 41 bar(600 psi) Maximum Operating Temperature 45ºC(113ºF)
Maximum Pressure Drop per Element 1.0 bar (15 psi)
pH Range, Continuous Operation 2-11 pH Range, Chemical Cleaning 1-13
Maximum Feed Silt Density Index (SDI15) 5.0 Free Chlorine Tolerance < 0.1 ppm
 

Note

  1. Permeate flow rates for individual elements may vary ±15%.
  2. Membrane active areas may vary ±4%.
  3. Stabilized salt rejection is generally achieved after continuous using for 24-48 hours, which depending on feed water qualities and operating conditions.
High Flow RO Membrane Water Purification 8040

 

High Flow RO Membrane Water Purification 8040