8 Interface Network Lightning Protector , 1000BPS RJ45 Surge Protective Device

China 8 Interface Network Lightning Protector, 1000BPS RJ45 Surge Protective Device, Find details about China Surge Protector, Ethernet Lightning Protector from 8 Interface Network Lightning Protector, 1000BPS RJ45 Surge Protective Device

Model NO.
OMS-RJ45/POE/1000/8
Shape
Cuboid
Material
Aluminium Alloy
Certification
ROHS, ISO9001
Brand
Omldeen
Trademark
OMLDEEN
Transport Package
Carton
Specification
48*119*180mm
Origin
Shenzhen, China
HS Code
8535400000
Model NO.
OMS-RJ45/POE/1000/8
Shape
Cuboid
Material
Aluminium Alloy
Certification
ROHS, ISO9001
Brand
Omldeen
Trademark
OMLDEEN
Transport Package
Carton
Specification
48*119*180mm
Origin
Shenzhen, China
HS Code
8535400000
Product introduction
Omldeen 1000m network signal lightning protection device (SPD, surge protector) is designed according to IEC and GB standards. It is mainly used to protect sensitive Ethernet 100m high-speed network communication lines, and to protect it from major damage caused by lightning induced voltage, grid voltage fluctuation interference, electrostatic discharge and transient surge voltage caused by heavy load startup. It is applied in lightning protection zone 1-2 and 2-3.

Functional features
1. High current capacity: 10kA (8 / 20 μ s), high speed reaction (10 ns), low loss (≤ 0.2db);
2. Internal use of two-stage series compound protection, low residual pressure, long service life;
3. It has three protection functions of over-current, over-voltage and clamping, with fast response speed;
4. When the lightning surge invades, there is no need to stop the electrical equipment, which does not affect the normal operation of the equipment;
5. It has the function of clutter isolation to isolate interference signal and enhance signal transmission rate
6. Single way / 4-way / 8-way / 16-way / 24-way can be selected freely, which makes installation more convenient and takes no space.

Installation method of lightning arrester
1. This series of network signal lightning arresters can be directly installed in series at the front end of the protected equipment (or system), and the closer the installation is to the protected equipment (or system), the better.
2. The input terminal (in) of the lightning arrester is connected with the signal line, and the output end (out) of the lightning protector is connected with the protected equipment.
3. PE line of lightning arrester must be strictly equipotential connected with lightning protection system, otherwise it will affect the working performance.
4. The product does not need special maintenance and should be installed close to the equipment end as far as possible; when the working system is in trouble and the lightning arrester is suspected, the lightning protector can be removed and checked again. If it is restored to the state before use, it should be replaced.
5. Lightning arrester grounding shall be connected with the shortest possible wire. The lightning arrester grounding adopts terminal grounding mode, and the grounding wire must be connected with the lightning protection ground wire (or the shell of the protected equipment). The shielding wire of the signal can be directly connected to the grounding terminal.
6. If the lightning arrester is installed under the condition that it does not exceed the requirements, it does not need long-term maintenance, and only needs routine maintenance of the system; if there is a problem in the signal transmission during the use process, the signal transmission returns to normal after replacing the lightning protector, which indicates that the lightning protector has been damaged and needs to be repaired or replaced.

Precautions for installation of surge protector
1. All ports of lightning arrester output end are connected with the protected equipment;
2. Do not connect the input and output circuits in reverse or wrong way;
3. The closer the lightning arrester is installed at the front end of the protected equipment, the better the effect is;
4. The equipment needs regular inspection and must be replaced immediately after the deterioration of the product;
5. The grounding must be good and the grounding resistance should not be greater than 4 ohm

technical parameter
nameGigabit network signal lightning protector
modelOMS-RJ45/1000/8
SPD categoryComposite SPD
Nominal operating voltage5V
Maximum continuous operating voltage 8V
Nominal load current500mA
C2 total nominal discharge current (8 / 20 μ s)      In3kA
Maximum discharge current Imax (8 / 20 μ s)       Imax5kA
Voltage protection level     Up   x-x≤15V
Voltage protection level     Up   L-PG ≤450V
insertion loss≤0.2dB
transmission speed1000Mbps
Response time≤1ns
Protective core wire1,2,3,6,4,5,7,8
Protection levelIP20
Interface typeRJ45
Shell materialAluminum alloy or metal plate
temperature range-25-+80ºC
Test standardIEC61643-21
 
8 Interface Network Lightning Protector, 1000BPS RJ45 Surge Protective Device
8 Interface Network Lightning Protector, 1000BPS RJ45 Surge Protective Device



FAQ 
Q: Are you a factory or a trade company?  
A: We are the factory. 

Q: Where are your products distributed?   
A: Our products are distributed all over the world, Main market are Europe, North America, the United Arab Emirates, Africa and so on. 

Q: Can I have a sample?    
A: Yes, but according to our company's policy, we provided free samples, while you should pay the freight fee; the sample can be delivered by TNT/DHL/UPS/FEDEX. 

Q: Which port is the nearest from you?   
A: Guangzhou port or Shenzhen Port or Hong Kong port.

Q: What's your lead time? 
A: Sample lead time: 3~5 working days. Mass production: usually 10~30days.
For big orders, honestly, it depends on the order quantity and designs. 

Q: When can I get the price? 
A: We usually quote within 24 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your email so that we will regard your inquiry as priority.
 
Q: Can you do the design for us? 
A: Yes, we have a professional team having rich experience in molding design, electrical system developing and manufacturing. Please just tell us your ideas and we will help you to carry out your ideas into a perfect artwork. You can pay for the molding fee and own the mold by yourself or we can cooperate on the molding. 