HEPA Fliter H13 for Cleanroom

China HEPA Fliter H13 for Cleanroom, Find details about China Replaceable High Efficiency Ceiling Module, HVAC Systems in Pharmaceuticals from HEPA Fliter H13 for Cleanroom

Casing Dimension (Top Air Inlet)
410mmx410mmx280mm
Box Casing
Epoxy Powder Coated SPCC
Damper
Epoxy Powder Coated SPCC
Filter Efficiency (En1822:2009)
H13, H14, U15, U16
Faceguard
Stainless Steel (SUS 304)
Filter Brackets
Galvanized Steel
Optional Accessories
PE
Applications
Pharmaceutical
Trademark
Wiskind
Specification
Customizable
Origin
Shandong Prov., China
HS Code
8421391000
Casing Dimension (Top Air Inlet)
410mmx410mmx280mm
Box Casing
Epoxy Powder Coated SPCC
Damper
Epoxy Powder Coated SPCC
Filter Efficiency (En1822:2009)
H13, H14, U15, U16
Faceguard
Stainless Steel (SUS 304)
Filter Brackets
Galvanized Steel
Optional Accessories
PE
Applications
Pharmaceutical
Trademark
Wiskind
Specification
Customizable
Origin
Shandong Prov., China
HS Code
8421391000
High efficiency particulate air (HEPA) filters and ultra-low particulate air (ULPA) filters are air filter designed to trap a vast majority of very small particulate cont

Product Description

Good design, high density filter material, targeted filtering
The PuriceliII HEPA filter is extremely effective at filtering small particulate matter in the air. The filter element is made of high quality glass fiber filter material (pleated treatment) and linear hot melt adhesive strip partition board to minimize the resistance to air. V-shaped structure assembly, can accommodate more filter material.
Air volume up to 4000m/h, save installation space
The Purice1III is designed for high air volume and is suitable for high air volume environments. Reduce the number of filters used in the fresh air system under the same air volume, save space and reduce energy consumption. In existing systems, Purice1III's large filter material area ensures low drag and reduces operating costs.

Detailed Photos

 

HEPA Fliter H13 for Cleanroom
HEPA Fliter H13 for Cleanroom
HEPA Fliter H13 for Cleanroom

 

Frame galvanized frame, stainless steel frame
The filter material is moisture proof and flame retardant ultrafine glass fiber
The product thickness is 292mm
Filtration efficiency H13/H14(EN1822)
Fire rating UL900 certification
Continuous operation temperature ≤70ºC
Recommended final resistance ≤600Pa
Ventilation and cleaning rooms for commercial and industrial use
The main application
Final filtration of ventilation and air conditioning system
Sealant flame retardant phosphorus - free polyurethane adhesive

Product Parameters

HEPA Fliter H13 for Cleanroom

Characteristic :
 

1. Operating Conditions
Continuous operating temperature: Max. 80°C Operating relative humidity: ≤100 (%RH)

2. Box Casing
Material: Epoxy powder coated SPCC

3. Damper
Material: Epoxy powder coated SPCC

4. Filter Efficiency (EN1822:2009)
H13, H14, U15, U16

5. Faceguard

Material: Stainless steel (SUS 304) / epoxy powder coated SPCC / epoxy powder-coated aluminium.

6. Filter Brackets

Material: Galvanized steel

7. Optional Accessories 

Thermal insulator: PE 

8. Applications
Pharmaceutical, Laboratories, Healthcare, Hospital, General

Company Profile

Founded in the late 1970s, Shandong WISKING Steel Building Stock Co., Ltd (WISKIND stock code: 830906) focuses on R & D and manufacture of metal wall systems for construction metal houses. It is committed to providing customers with the most valuable building enclosures. A protection system as a whole solution. Through many years of unremitting efforts and persistent pursuit, has been the customer and the community unanimously approved, has been rated as national high-tech enterprises, provincial enterprise technology center, advanced private enterprises in Shandong Province, Shandong Province construction industry modernization production base, Shandong patent star Enterprises, Shandong Province Shou contract re-credit enterprises such as the honorary title, is ISO9001 & ISO14001 certified enterprises.
 

Shandong Wish WISKIND Clean Technology Co., Ltd. is a subsidiary of WISKIND to develop the clean industry market. Focusing on R & D and manufacturing of cleanroom enclosure system, relying on WISKIND's 40 years of industry R & D experience and resource integration advantages, it has become a professional Of the cleanroom enclosure system service providers, modular cleanroom advocates and practitioners and the largest domestic production capacity of the clever plate intelligent manufacturers.

WISKIND has always believed that to create value for customers, so that the customer works better, it is our responsibility forever. Depending on the quality of products such as life, integrity and innovation, and innovation, and the pursuit of customers, employees, the community of win-win situations, the opportunities and challenges in the continuous development, is toward a higher, faster and stronger goal.


 

HEPA Fliter H13 for Cleanroom
HEPA Fliter H13 for Cleanroom

 

Our Advantages

 

HEPA Fliter H13 for CleanroomHEPA Fliter H13 for Cleanroom

Installation Instructions

 

Cleanroom enclosure system is composed of a cleanroom wall panel system, ceiling system, door, window and cleanroom equipment.
Today's cleanroom has been widely used in electronics, aerospace, machinery, chemical, pharmaceutical, food, medical, biological engineering......All walks of life. Moreover, with the rapid development of national economy and scientific research, the application of air shower and the cleanroom will be more and more extensive and essential.

 

To ensure the filtration efficiency of filters and the cleanliness of the cleaning system, the installation of HEPA filters must comply with the requirements of the cleanroom construction and acceptance code or the design drawing.

1. Preparation before installation in order to prevent pollution of HEPA filters, the inspection and installation must be carried out after the installation of the air cleaning system is completed, the air conditioner, HEPA filter box, air duct and clean room are cleaned, and the ice energy can be carried out after the test run of each individual equipment of the air conditioning system and the stable amount of dust blown out of the air duct. Before installation, check the flatness of the filter frame or the end face of the edge mouth. The allowable deviation of flatness of the end face shall not exceed 1mm.

If the flatness of the end face exceeds the allowable deviation, only the end face of the frame installed by the filter is allowed to be modified or adjusted, and the outer frame of the filter itself is not allowed to be modified. Otherwise, the filter material or sealing part of the filter will be damaged and the filtering effect will be reduced.

2. Installation requirements: when installing a Hepa filter, ensure the airflow direction is consistent with the arrow mark on the outer box. When the high-efficiency filter assembled with corrugated plate is installed vertically, the corrugated plate must be perpendicular to the ground and not reversed. The sealing of the HEPA filter and the frame of the assembled Hepa filter generally adopts the top tight method and the compression method.



Any question about this products,pls feel free to contact with me online!