Suntree Brand Sw8 (DW45) Good Quantity 630-6300A Air Circuit Breaker Acb 3p/4p CE Switchgear Circuit Breaker Draw out Type Acb 3 Pole Acb 1000A 2000A

China Suntree Brand Sw8 (DW45) Good Quantity 630-6300A Air Circuit Breaker Acb 3p/4p CE Switchgear Circuit Breaker Draw out Type Acb 3 Pole Acb 1000A 2000A, Find details about China Electrical Switch, Air Circuit Breaker from Suntree Brand Sw8 (DW45) Good Quantity 630-6300A Air Circuit Breaker Acb 3p/4p CE Switchgear Circuit Breaker Draw out Type Acb 3 Pole Acb 1000A 2000A

Model NO.
SW8-6300 SW8-4000 SW8-2000 SW8-1000
Poles Number
4
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CCC
Trademark
SUNTREE
Transport Package
Wooden
Specification
According to products requiement
Origin
China
HS Code
853620000
Model NO.
SW8-6300 SW8-4000 SW8-2000 SW8-1000
Poles Number
4
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CCC
Trademark
SUNTREE
Transport Package
Wooden
Specification
According to products requiement
Origin
China
HS Code
853620000

Air Circuit Breaker SW8-6300, DW-45-6300Acb, Multifunction Circuit Breaker, Drawer Type Circuit Breaker, Fixed Circuit Breaker.

Suntree Brand Sw8 (DW45) Good Quantity 630-6300A Air Circuit Breaker Acb 3p/4p CE Switchgear Circuit Breaker Draw out Type Acb 3 Pole Acb 1000A 2000A
Product Description

SW8(DW45) 4P 6300A Draw out type intelligent circuit breaker with overload  under voltage relay 
Circuit breaker is generally composed of contact system, arc extinguishing system, operating mechanism, tripper, housing and so on.
The main characteristics of circuit breaker are: rated voltage Ue; rated current In; setting range of tripping current for overload protection (Ir or Irth) and short circuit protection (Im); rated short circuit breaker current (Icu for industrial use; Icn for household use).
1.Auxiliary contacts: contacts that are mechanically connected with the main circuit dividing and closing mechanism of a circuit breaker. They are mainly used for displaying the dividing and closing states of a circuit breaker. They are connected to the control circuit of a circuit breaker and are controlled or interlocked by the circuit breaker.
2.Alarm contacts: Alarm contacts for circuit breaker accidents, and this contact only when the circuit breaker trips off and breaks, mainly for the load of the circuit breaker overload short circuit or undervoltage and other faults and free tripping, alarm contacts from the original normal open position to the closed position.
3.Excitation tripper: Excitation tripper is a kind of tripper driven by a voltage source. Its voltage has nothing to do with the voltage of the main circuit. Excitation tripper is an accessory for long-distance operation of switch-off.
4.Undervoltage tripper: Undervoltage tripper is a tripper that causes circuit breakers to open with or without delay when its terminal voltage falls to a specified range.
5.Electric Operator: This is an accessory for remote automatic switching and closing circuit breakers.
6.Extended handle: It is an external extended handle directly mounted on the handle of circuit breaker. It is generally used on large capacity circuit breakers of 600A and above for manual switching-off operation.
7.Handle locking device: a clamp is installed on the handle frame, punched on the handle, and then locked with a padlock. Mainly used for closing circuit breaker.
Suntree Brand Sw8 (DW45) Good Quantity 630-6300A Air Circuit Breaker Acb 3p/4p CE Switchgear Circuit Breaker Draw out Type Acb 3 Pole Acb 1000A 2000A
Product code:Suntree Brand Sw8 (DW45) Good Quantity 630-6300A Air Circuit Breaker Acb 3p/4p CE Switchgear Circuit Breaker Draw out Type Acb 3 Pole Acb 1000A 2000A
Service conditions:

Suntree Brand Sw8 (DW45) Good Quantity 630-6300A Air Circuit Breaker Acb 3p/4p CE Switchgear Circuit Breaker Draw out Type Acb 3 Pole Acb 1000A 2000A
Technical specification:
Model                                             SW8-1000SW8-2000SW8-3200SW8-4000SW8-6300 
IEC60947-2 GB/T14048.2
Shell frame level current Inm(A) 10002000320040006300
Electrical Performance        
Number of poles  3P4P3P4P3P4P3P4P3P4P
Operating frequency(Hz) 5050505050
Rated working voltage  Ue(V) 400/690400/690400/690400/690400/690
Rated current +40ºC  In(A) 2,004,006,308,001,0006,308,001,000,125,010,000,000200,025,003,200320,036,004,000400,050,006,300
Rated insulation voltage Ui(V) 8001000100010001000
Rated impulse withstand voltageUimp(kV) 812121212
Pole N rated current  In(A) 100%100%100%100%100%
Breaking type   -MH --
Rated ultimate short-circuit segmentation capability        Icu(kA)400V5085100100120
690V3050656580
Rated running short-circuit segmentation capability        Ics(kA)400V355065656580
690V2540505070
Rated short-time withstand current(effective value)Icw(kA)400V35(1s)50(1S)65(1S)65(1S)65(1S)85(1S)
690V25(1S)40(1S)50(1S)50(1S)65(1S)
Operating time(ms)Disjunction23~3223~3223-3223-3223-32
Switch off<70<70<70<70<70
Flashover distance(mm) 00000
Service lifefor mechanicalFree of maintenance1500010000500050003000
service life(times)Maintained300002000010000100006000
Electrical life (times)400V6000650030001500500
900V300030001500750300
Separating function (drawer type)OOOOO
Protection:
Intelligent controllerOOOOO
Pole N protection capability (only 4P and 3P+N)OOOOO
Connection And Installation:
Utilization categoryBBBBB
Installation categoryCircuit breaker(including the primary lateral line circle)IVIVIVIVIV
Auxiliary circuit (except for primary coil RB)IIIIIIIIIIIIIII
Pollution degree 33333
Connection mode HorizontalVertical/HorizontalVertical/HorizontalVertical/HorizontalVertical/HorizontalVertical/Horizontal
Incoming line methodUp/DownUp/DownUp/DownUp/DownUp/Down
Installation MethodFixed Type (3/4)Drawer Type(3/4)Fixed Type (3/4)Drawer Type(3/4)Fixed Type (3/4)Drawer Type(3/4)Fixed Type (3)Drawer Type(3/4)Fixed Type (3/4)Drawer Type(3)
Outline DimensionWidth(W)274/344284/354362/457407/500422/537435/550537550/790813/928928
Depth(D)289373373461363494424494/504504504
Height(H)315362402432402432402432/452433433
O Standard ConfigurationO Optional-None         



Structure diagram:
Suntree Brand Sw8 (DW45) Good Quantity 630-6300A Air Circuit Breaker Acb 3p/4p CE Switchgear Circuit Breaker Draw out Type Acb 3 Pole Acb 1000A 2000A
1.With drawable-breaker;2.Fixed-breaker
 
3.Intelligent controller;
 
4.Operating mechanism;
 
5.Auxiliary contact
6.Locking-device7.Arc chute;
 
8.Secondary connecting part;
 
9.Wire-cable mechanical interlock;
 
10.Connecting-rod type mechanical interlock;
 
11.Shunt release;
 
12.Closing electromagnet;
 
13.Under-voltage release14.Motor-driven energy-storage mechanism;
 
15.Handle;
 
16.Fixed plate.
 
    

Suntree Brand Sw8 (DW45) Good Quantity 630-6300A Air Circuit Breaker Acb 3p/4p CE Switchgear Circuit Breaker Draw out Type Acb 3 Pole Acb 1000A 2000A
Suntree Brand Sw8 (DW45) Good Quantity 630-6300A Air Circuit Breaker Acb 3p/4p CE Switchgear Circuit Breaker Draw out Type Acb 3 Pole Acb 1000A 2000A




Production Certification :
Suntree Brand Sw8 (DW45) Good Quantity 630-6300A Air Circuit Breaker Acb 3p/4p CE Switchgear Circuit Breaker Draw out Type Acb 3 Pole Acb 1000A 2000A