Magnetic Type B RCCB 2p 63A with CB Ce SGS Certificate for EV Charging Station Protection

China Magnetic Type B RCCB 2p 63A with CB Ce SGS Certificate for EV Charging Station Protection, Find details about China Type B RCD, 2p Type B RCCB from Magnetic Type B RCCB 2p 63A with CB Ce SGS Certificate for EV Charging Station Protection

Poles Number
4p
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CB, SGS
Trademark
RAVELO
Specification
20 pcs per carton
Origin
China
HS Code
8536200000
Poles Number
4p
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000, CE, CB, SGS
Trademark
RAVELO
Specification
20 pcs per carton
Origin
China
HS Code
8536200000
Description:
· Type B RCCB is the secret that makes Electric Vehicle Charging Point much safer than traditional charging point. It is a multiple purpose safety device that manage all potential residual current, and protect users from potential electric shock.
· AC residual current.
· Pulsating DC residual current.
· Sinusoidal half-wave current superposes 6mA smooth DC residual current.
· Multifrequency recombination residual current.
· Less than 1000Hz AC residual current.
· AC current superimposes 10mA or 0.4In smooth DC residual current.
· Sinusoidal half-wave current superposes 10mA or 0.4In smooth DC residual current.
· DC residual current generated by a Single-phase rectifier circuit.
· DC residual current produced by three-phase rectifier circuit.
· Smooth DC residual current.
· Control electric circuits.
· Protect people against indirect contacts and additional protection against direct contacts.
· Protect installations against fire hazard due to insulation faults.
· Residual current circuit breakers are used in housing, tertiary sector and industry.


Detectable wave form:
· Type B
Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.
· Tripping sensitivity
30mA - additional protection against direct contact.
100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide protection against indirect contacts.
300mA - protection against indirect contacts, as well as fire hazard.
· Tripping time
Instantaneous
It ensures instantaneous tripping (without time-delay).


Technical specification:
StandardIEC/EN 62423 AS/NZS 61008-1
Type (wave form of the earth leakage sensed)B
Number of Pole1P+N, 3P+N
Rated voltage Ue1P+N 240v~, 3P+N 415v~
Rated Current25A, 32A, 40A, 63A
Insulation Voltage500V
Short-circuit Current500(In=25A/40A)
Rated residual making630(In=63A)
Short-circuit current Inc=IΔc10,000A
Rated Residual Operating Current30, 100, 300mA
Break time under IΔn≤0.1s
Rated frequency50Hz
Rated Impulse Withstand Voltage(1.2/50)Uimp4,000V
Dielectric Test Voltage at ind. Freq. For 1 min2.5kV
Pollution degree2
Mechanical Life10,000 cycles
Electrical Life4,000 cycles
IP Rating20
Fault Current IndicatorYes
Ambient Temperature (with-daily average ≤ 35ºC )-25...+40ºC
Storage temperation-25...+70ºC

Outline dimension (mm):
Magnetic Type B RCCB 2p 63A with CB Ce SGS Certificate for EV Charging Station Protection

Magnetic Type B RCCB 2p 63A with CB Ce SGS Certificate for EV Charging Station Protection
Magnetic Type B RCCB 2p 63A with CB Ce SGS Certificate for EV Charging Station Protection
Magnetic Type B RCCB 2p 63A with CB Ce SGS Certificate for EV Charging Station Protection