Customized 120A Three Phase 2 Coils Latch Relay with Shunt/CT/Terminal

China Customized 120A Three Phase 2 Coils Latch Relay with Shunt/CT/Terminal, Find details about China Magnetic Latching Relay, 3 Phase Latching Relay from Customized 120A Three Phase 2 Coils Latch Relay with Shunt/CT/Terminal

Model NO.
IM1201T
Protective Characteristics
Enclosed Rlay
Action Principle
Electromagnetic Type
Size
Miniature
Type
Electric Parameter Relay
Product Name
120A Three Phase 2 Coils Latch Relay
Contact Material
Agsno2
Rated Load
120A, 250VAC
Coil Voltage
5/6/12/24/36VDC
Color
Black
Trademark
IVY
Transport Package
Cartons/Pallet
Specification
78.6*40.3*37.8mm
Origin
Zhejiang, China
HS Code
8536411000
Model NO.
IM1201T
Protective Characteristics
Enclosed Rlay
Action Principle
Electromagnetic Type
Size
Miniature
Type
Electric Parameter Relay
Product Name
120A Three Phase 2 Coils Latch Relay
Contact Material
Agsno2
Rated Load
120A, 250VAC
Coil Voltage
5/6/12/24/36VDC
Color
Black
Trademark
IVY
Transport Package
Cartons/Pallet
Specification
78.6*40.3*37.8mm
Origin
Zhejiang, China
HS Code
8536411000
Customized 120A Three Phase 2 Coils Latch Relay with Shunt/CT/TerminalCustomized 120A Three Phase 2 Coils Latch Relay with Shunt/CT/TerminalCustomized 120A Three Phase 2 Coils Latch Relay with Shunt/CT/Terminal
Basic DataDimension(mm)78.6×40.3×37.8
Weight ( g )TBD
Contact Arrangement3A/3B
Contact MaterialAuAg
Ambient Temperature-40~+70ºC
Ambient HumidityTBD
Vibration10~55Hz,1.5mm(DA)
Specification DataNominal Voltage5~48VDC
Power ConsumptionSingle Coil:3.0W, Dual Coil:6W
Max. Switching Voltage250VAC
Max. Switching Current120A
Max. Switching Power30000 VA
Contact Resistance<2.0 mΩ
Insulation Resistance1000MΩ(DC 500V)
Dielectric Creepage8mm
Dielectric StrengthAcross Open Contact>2000VAC   1min
Coil to Contact>4000VAC   1min
Electrical Life>10,000cycles
Mechanical Life>100,000cycles
Picking-up & Release Time<=30ms
Pulse Duration>=100ms
Functional Shock Resistance10G
Destructive Shock Resistance100G

Customized 120A Three Phase 2 Coils Latch Relay with Shunt/CT/TerminalCustomized 120A Three Phase 2 Coils Latch Relay with Shunt/CT/TerminalCustomized 120A Three Phase 2 Coils Latch Relay with Shunt/CT/TerminalCustomized 120A Three Phase 2 Coils Latch Relay with Shunt/CT/TerminalCustomized 120A Three Phase 2 Coils Latch Relay with Shunt/CT/TerminalCustomized 120A Three Phase 2 Coils Latch Relay with Shunt/CT/Terminal           Cautions of Latching Relay:

             1.Suggestions of relay's input
            (1)Polarity-Please check the polarity inside of our technical specification, if single coil then"+ -" or "- +"are fine,
            you can change it by one pulse.If double coil then it's necessary to confirm "-+-" or "+-+"before leaving the our factory.
            (2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5
            times or 2 times of value or lower driving condition plz confirm with our engineer.
            (3)Relays'contact status may be changed during transportation or installation due to impact of external force,
            therefore please reset to the required status.
 
            2.Suggestions of relay's output
            (1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
            the installation.
            (2)When the relay will be connected with screw or bolts to the relays' terminals, plz make sure your connection is
            fastened and prevent relay from damages or other safety problems due to temp. Rise..
            (3)The sampling signal wires of products are limited, please do not pull or torque during installation.