Pjg-630/6 Mine-Used Flameproof and I. S. High- Voltage Vacuum Power Distribution Device, Switch

China Pjg-630/6 Mine-Used Flameproof and I. S. High- Voltage Vacuum Power Distribution Device, Switch, Find details about China Vacuum Distribution Equipment, Feeder Switch from Pjg-630/6 Mine-Used Flameproof and I. S. High- Voltage Vacuum Power Distribution Device, Switch

Model NO.
Pjg-630/6
HS Code
8537209000
Model NO.
Pjg-630/6
HS Code
8537209000
(one) Application
PJG¨-630/6 Mine-used Flameproof and I.S. High- voltage Vacuum Power Distribution Device is suitable for underground coal mines with explosive gases such as methane. It can control, protect and measure 3-phase neutral-point ungrounded power supply systems which are at the rated voltage 6 kV rated current up to 630 A.
(two) Features
1.A unique Fast-open structure makes the door easier to open and close;
2.Isolation panel is added, with interior illumination;
3.1t is composed of an explosion-proof enclosure and functional core. The circuit breaker can be easily withdrawn from its space either for maintenance purposes or replacement.
4.With exclusive protection for underground coal mines, it has protection functions such as overload, short-circuit, directional power leakage, insulation fault, over or under voltage, air, electricity and methane interlocking. Its strong anti-interference ability adapts it to the hazardous environments in coal mines. With an LCD display drop-down menu it gives detailed real-time information about the working environment and the humanized interface is convenient for operation and routine inspection.
5.Four types of structure a, b, c, d are available so as to meet different demands of current-carrying, communication, feedback, or direct control;
6.A spring energy storage type circuit breaker is used. It can be switched on or off automatically or manually.
7.The remote control signal is intrinsically safe.
8.With the communication interface it enables networking with the communication station and remote monitoring function.

(three) Technical Parameters
Raged Voltage: 6KVRated times for short-circuit breaking current: 30 times
Maximum Working Voltage: 12 KV/7.2 KVRated Thermal Stability Time:2S
Rated Frequency: 50 HzMechanical Life: 100000 times
Rated Current(A):50,100,200,300,400,500,630Mechanical Life of Isolation Switch: 2000 times
Rated short-circuit breaking current (valid): 12.5KAAuto Closing Voltage: DC135V
Rated short-circuit closing current (peak): 31.5RAAuto Opening Voltage: DC24V
Rated dynamic stability current (peak): 31.5kAMaximum Open-circuit Voltage of I.S. circuit:12.5V
Rated thermal stability current (valid): 12.5kAMaximum Short-Circuit Current of I.S. Circuit:22mA