Gas Insulated Load Break Switch

China Gas Insulated Load Break Switch, Find details about China Load Break Switch, Sf6 Load Break Switch from Gas Insulated Load Break Switch

Model NO.
RPS
HS Code
8535210000
Model NO.
RPS
HS Code
8535210000

Pole mounted Load break switch 

Polemount LBS with Manual operation mechanism

- Pole mounted SF6 Gas insulated load break switch (Pole mounted switch disconnector) type RPS-12/27/38-20 is suitable for the rated voltage up to 40.5kV,rated current 400A-630A, 50/60Hz power system.

-RPS type polemount LBS is SF6 breaking on load break switch, ie. on load switch disconnector.
Rated voltage: up to 40.5 kV
Rated current: 400 to 630 A
Insensitive to the environment.

Options:

E2/E3

Manual or remote control

CT/PT/VS 
Gas pressure guage

Low pressure lockout

SCADA capabilities
etc...


· Summary

ROCKWILL® Electric strives to bring our customers the latest technology and competitive pricing and best service for distribution automatic.
RPS is an SF6-insulated, outdoor pole mounted load break switch family for overhead lines and specifically designed for use in modern remote controlled distribution automation systems. The RPS offers reliable maintenance free operation even in the most demanding climatic conditions including salt laden atmospheres, corrosive industrial pollution, snow and ice. It has excellent load breaking and fault making capacity and satisfies the isolation requirements specified for load break switch. The earthed metal tank prevents all possible leakage currents across an open switch. RPS can be manually operated or motor operated for local and remote electric control, upgraded.

·Service environment

1.Air temperature: Maximum temperature: +85ºC; Minimum temperature:-45ºC
Humidity: Monthly average humidity 95%; Daily average humidity 90% .
Altitude above sea level: Maximum installation altitude: 2500m or more higher.
Ambient air not apparently polluted by corrosive and flammable gas, vapor etc. No frequent violent shake

·Offering

With optional classes for rated current range:
--Type RPS 15, Rating6-20 kV with 400A, 16 kA up to 1250A, 20kA;
--Type RPS 27, Rating22-27 kV with 400A, 16 kA up to 1250A, 20kA;
--Type RPS 38, Rating30-40.5 kV with 400A, 16 kA up to 1250A, 20kA;
With optional classes for different grid application installation:
Section function (Section)
50 Instantaneous/Definite-Time Overcurrent(P.OC)
51 Phase Time-Overcurrent(P.Fast curve/P.Delay curve)
Overload (N.Fast curve/N.Delay curve)
50N Residual Ground Instantaneous/Definite-Time Overcurrent(G.OC)
51N Residual Ground Time-Overcurrent (G.Fast curve/G.Delay curve)
50SEF Sensitive Earth Fault (SEF)
51c Cold Load(Cold load)
TRSOTF Switch-Onto-Fault(SOTF)
59 Over Voltage(L.Over volt)
27 Under Voltage (L.Under volt)
Monitoring Functions: 
Primary/Secondary Phases and Earth Currents 
Direction 
Primary/Secondary Line and Phase Voltages 
Apparent Power and Power Factor 
Real and Reactive Power 
Historical Demand Record 
Positive Phase Sequence Voltage & Current 
Negative Phase Sequence Voltage & Current 
Zero Phase Sequence Voltage 
Frequency 
Binary Input/Output status 
Trip circuit healthy/failure 
Time and date 
Fault records 
Event records

 

·Time-Overcurrent Curves

The following information describes the curve timing for the curve and time dial settings made for the time-overcurrent elements The time-overcurrent relay curves in conform to IEEE C37.112-1996 IEEE Standard Inverse-Time Characteristic Equations for Overcurrent Relays.
 

Gas Insulated Load Break Switch

 Creepage Distances of RPS

Terminal to ground creepage15kV BIL 95/110kV27kV BIL125/150kV38kV BIL 170/200kV
Composite bushing564mm840mm1400mm
Porcelain bushing556mm708mm1250mm


·Current transformer and Voltage sensor

Part NumberRPS-15RPS-27RPS-38
ManualMotorizeManualMotorizeManualMotorize
Current transformer/3/3/3
Voltage sensor/3/6/3/6/3/6

Note: Current transformers and voltage sensors can be customized according to requirements.

·Standards for reference

IEC 62271-1 IEC 62271-102 IEC 62271-103 
High-voltage switchgear and controlgear. Part 103: switches for rated voltage above 1 kV up to and including 52 kV




Gas Insulated Load Break Switch
Front: Color clear O/C indicator                     Rear:Highly reliable explosion-proof                                                                                                                         valve,Inflatable/deflation integrated device.
 
Insulation level
Rated voltagekV152738
Power frequency withstand voltage, 50 Hz
- to earth and between phaseskV285070
- across the isolating distancekV326080
Lightning impulse withstand voltage
- to earth and between phaseskV75125170
- across the isolating distancekV85145195
Current ratings
Rated normal currentA400/630/800/1250
Mainly active load breaking currentA400/630/800/1250
Number of breaking operations COtimes400
Line-charging breaking currentA11.52
Cable-charging breaking currentA101620
Earth fault breaking currentA5050130
Cable charging breaking current    
under earth fault conditionsA282880
No-load transformer breaking currentA  20
Short-circuit ratings
Short-time withstand current, IkkA/s20 kA/4 s20 kA/4 s20 kA/4 s
Peak withstand currentkA505050
Short-circuit making currentkA505050
Number of making operations
- main switch 50 kA (CL E3)times555
- main switch 31.5 kA (CL E3)times101010
- earthing switch 50 kA (CL E2)times333
- earthing switch 31.5 kA (CL E3)times555
Ambient air temperature limits -40°C...+60°C
Mechanical endurance (number of CO operations)
- main switchtimes500050005000
- earthing switchtimes200020002000
Filling pressure (+20°C)bar (abs)1.4-1.51.4-1.51.8-1.9
Alarm pressure (+20°C)
- density switchbar (abs)1.21.21.65
- density gaugebar (abs)1.21.21.6
- low gas lock-out mechanismbar (abs)1.11.11.6
Weight
Composite bushingkg115125135
Porcelain bushingkg125135155
Motorize Add 20kg
Degree of protection of the mechanism box IP67