UCS2 Ceramic Capacitive Pressure Sensor Benefits:* Dry capacitive ceramic sensor
* Basic ceramic material (99.9 % Al2O3 )
* Extremely high overload limit
* Absolutely resistant to wear
* High temperature stability
* High long-term stability
* No hysteresis
* Corrosion-resistant
* Active electronics
* sensor-specific signal conditioning
* High-accuracy pressure measurement with temperature stability
UCS2 Ceramic Capacitive Pressure Sensor Measuring Principle:The Ceracore UCS2 basic material is Al2O3(99.9 %), a highly resistant ceramic material for many aggressive gases and liquids. Cylindrical ceramic components (diaphragm, meter body) are bonded to form a high- strength, hermetically sealed pressure sensor element. With absolute pressure sensors, the vacuum of 3.0 x 10-6 mbar created in the production process between the diaphragm and the meter body remains permanently. This permits pressure measurements related to the vacuum. With gauge pressure sensors, the back of the diaphragm is vented, i.e. this sensor measures the gauge pressure relative to the atmospheric pressure. Elec- trically, the sensor element represents a plate capacitor whose capacitance change is the dimension for the pressure change. The capacitive measuring process satisfies the highest requirements concerning resolution and reproducibility. Together with the hysteresis-free behavior of the material Al2O3, it is the basis for the excellent specifications of the sensor. In addition, the Ceracore UCS2 is a dry measuring cell, i.e. there is no separating diaphragm or filling fluid which could influence the measurement. A further advantage of the capacitive ceramic sensor is its high overload resistance. After removal of the overload, it returns to the initial position without any damage or hysteresis.
Technical Parameters:Power supply |
Supply voltage | 5 V DC stabilized, minimum 4.5 V / maximum 5.5 VInfluence of supply voltage: no influence on linearity / proportional on lower range-value / proportional on span, no influence on temperature compensation |
Current consumption | Maximum 2 mA at a supply voltage of 5 V |
Operating conditions: Installation |
Orientation | Arbitrary. Operate the sensor system with the diaphragm pointing downwards. Otherwise observe the position dependent zero point shift for small pressure ranges (≤ 400 mbar). |
Weight | approx. 17 to 23 g, depending on measuring range |
Operating conditions: Environment |
Ambient temperature range | -40 °C to +125 °C (also applies to storage temperature) |
Degree of protection | IP 00 as per DIN 60529 (IEC529); Climate class 3K3 DIN EN 60721-3-3 |
Operating conditions: Process |
Reference operating conditions | As per DIN IEC 60770, T = 25 °C |
Media | Gases and liquids |
Material | Diaphragm: aluminum oxide ceramic Al2O3 (99.9 %) |
Process temperature limits | -40 °C to +125 °C, compensation temperature -20 °C to +80 °C |
Thermal change | Thermal change of the lower range-value in the compensation temperature range: max. ±0.75 % of span, with extended specification ±1 % of span |
Thermal change of output span in the compensation temperature range: max. ±0.5 % of span. With Measuring ranges ≤0.4 bar ±0.8 % of span, with extended specification ±1 % of span |
Limiting medium pressure range | Overload limit: see "Ordering information" section, Overload influence: negligible |
Vacuum resistance | UCS2 with nominal value 400 mbar up to 70 bar: 0 mbar abs |
UCS2 with nominal value 200 mbar: 500 mbar abs (Version M in Ordering information) |
UCS2 with nominal value 100 mbar: 700 mbar abs (Version L in Ordering information) |
Ordering Information:Ceracore UCS2 | 10 | Sensor range; Overload (other measuring ranges and special versions on request) |
| | A | 0...100 mbar / 10 kPa/1.5 psi absolute; 4 bar/400 kPa/60 psi |
B | 0 to 200 mbar /20 kPa/3 psi absolute; 6 bar/600 kPa/ 90 psi |
C | 0 to 400 mbar /40 kPa/6 psi absolute; 6 bar/600 kPa/ 90 psi |
D | 0 to 1 bar /100 kPa/15 psi absolute; 10 bar/1 MPa/ 150 psi |
E | 0 to 2 bar /200 kPa/30 psi absolute; 18 bar/1.8 MPa/ 270 psi |
F | 0 to 4 bar /400 kPa/60 psi absolute; 25 bar/2.5 MPa/ 375 psi |
G | 0 to 10 bar /1 MPa/150 psi absolute; 40 bar/4 MPa/ 600 psi |
H | 0 to 20 bar /2 MPa/300 psi absolute; 40 bar/4 MPa/ 600 psi |
I | 0 to 40 bar /4 MPa/600 psi absolute; 60 bar/6 MPa/ 900 psi |
J | 0 to 70 bar /7 MPa/1050 psi absolute; 105 bar/10.5 MPa/ 1575 psi |
L | 0 to 100 mbar /10 kPa/1.5 psi relative; 4 bar/400 kPa/ 60 psi |
M | 0 to 200 mbar /20 kPa/3 psi relative; 6 bar/600 kPa/ 90 psi |
N | 0 to 400 mbar /40 kPa/6 psi relative; 6 bar/600 kPa/ 90 psi |
O | 0 to 1 bar /100 kPa/15 psi relative; 10 bar/1 MPa/ 150 psi |
P | 0 to 2 bar /200 kPa/30 psi relative; 18 bar/1.8 MPa/ 270 psi |
R | 0 to 4 bar /400 kPa/60 psi relative; 25 bar/5 MPa/ 375 psi |
S | 0 to 10 bar /1 MPa/150 psi relative; 40 bar/4 MPa/ 600 psi |
T | 0 to 20 bar /2 MPa/300 psi relative; 40 bar/4 MPa/ 600 psi |
U | 0 to 40 bar /4 MPa/600 psi relative; 60 bar/6 MPa/ 900 psi |
V | 0 to 70 bar /7 MPa/1050 psi relative; 105 bar/10.5 MPa/ 1575 psi |
20 | Calibration; Unit |
| A | see additional specification (special measuring ranges with extended specifications) |
1 | Sensor range; mbar/bar |
2 | Sensor range; kPa/MPa |
3 | Sensor range; psi |
UCS2 -A | A | 1 A 1 | AAA |
About JiuchengQualification and Certificate:
Product Packaging:We choose cartons and protective pads that can be recycled. This will maximize the protection of our products from damage during transportation.
Product Transportation:We only choose the global express service providers. We will deliver the goods to you at the most efficient speed.