TUV/UC3/RoHS Approval 90A 3 Phase Power Latch Relay with CT/Shunt

China TUV/UC3/RoHS Approval 90A 3 Phase Power Latch Relay with CT/Shunt, Find details about China Magnetic Latching Relay, Latching Relay from TUV/UC3/RoHS Approval 90A 3 Phase Power Latch Relay with CT/Shunt

Model NO.
IM901T
Protective Characteristics
Sealed Relay
Action Principle
Electromagnetic Type
Size
Miniature
Type
Electric Parameter Relay
Product Name
90A 3 Phase Magnetic Latching Relay with CT
Max. Switching Current
90A
Max. Switching Voltage
250VAC
Contact Arrangement
3A/3b
Nominal Voltage
6~48VDC
Power Consumption
Single Coil:3.0W, Dual Coil:6.0W
Max. Switching Power
22500 Va
Contact Material
Agsno2
Picking-up & Release Time
Less Than or Equal to 20ms
Ambient Temperature
-40~+70 Degree
Trademark
IVY
Transport Package
Cartons/Pallet
Specification
98*40*35.7mm
Origin
Zhejiang, China
HS Code
8536411000
Model NO.
IM901T
Protective Characteristics
Sealed Relay
Action Principle
Electromagnetic Type
Size
Miniature
Type
Electric Parameter Relay
Product Name
90A 3 Phase Magnetic Latching Relay with CT
Max. Switching Current
90A
Max. Switching Voltage
250VAC
Contact Arrangement
3A/3b
Nominal Voltage
6~48VDC
Power Consumption
Single Coil:3.0W, Dual Coil:6.0W
Max. Switching Power
22500 Va
Contact Material
Agsno2
Picking-up & Release Time
Less Than or Equal to 20ms
Ambient Temperature
-40~+70 Degree
Trademark
IVY
Transport Package
Cartons/Pallet
Specification
98*40*35.7mm
Origin
Zhejiang, China
HS Code
8536411000
TUV/UC3/RoHS Approval 90A 3 Phase Power Latch Relay with CT/ShuntTUV/UC3/RoHS Approval 90A 3 Phase Power Latch Relay with CT/Shunt
         Basic DataDimension(mm)98*40*35.7
Weight ( g )/
Contact Arrangement3A/3B
Contact MaterialAgSnO2
Ambient Temperature-40~+70ºC
Ambient Humidity45%~90%RH
Vibration10~55Hz,1.5mm(DA)
   Specification DataNominal Voltage6~48VDC
Power ConsumptionSingle Coil:3.0W, Dual Coil:6.0W
Max. Switching Voltage250VAC
Max. Switching Current90A
Max. Switching Power22500 VA
Contact Resistance<2 mΩ
Insulation Resistance1000MΩ(DC 500V)
Dielectric StrengthAcross Open Contact>2000VAC   1min
Coil to Contact>4000VAC   1min
Electrical Life>10,000cycles
Mechanical Life>100,000cycles
Picking-up & Release Time<=20ms
Pulse Duration/
Functional Shock Resistance10G
Destructive Shock Resistance100G
TUV/UC3/RoHS Approval 90A 3 Phase Power Latch Relay with CT/ShuntTUV/UC3/RoHS Approval 90A 3 Phase Power Latch Relay with CT/ShuntTUV/UC3/RoHS Approval 90A 3 Phase Power Latch Relay with CT/ShuntTUV/UC3/RoHS Approval 90A 3 Phase Power Latch Relay with CT/ShuntTUV/UC3/RoHS Approval 90A 3 Phase Power Latch Relay with CT/Shunt
TUV/UC3/RoHS Approval 90A 3 Phase Power Latch Relay with CT/Shunt
Cautions of Latching Relay:

1.Suggestions of relay's input
(1)Polarity-Please check the polarity inside of our technical specification, if single coil then"+ -" or "- +"are fine,
you can change it by one pulse.If double coil then it's necessary to confirm "-+-" or "+-+"before leaving the our factory.
(2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5
times or 2 times of value or lower driving condition plz confirm with our engineer.
(3)Relays'contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status.
 
2.Suggestions of relay's output
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
the installation.
(2)When the relay will be connected with screw or bolts to the relays' terminals, plz make sure your connection is
fastened and prevent relay from damages or other safety problems due to temp. Rise..
(3)The sampling signal wires of products are limited, please do not pull or torque during installation.