China Non Contact Human Body Temperature Monitoring Thermal Screening Camera for Airport Railway Bank Hospital Metro, Find details about China Infrared Camera Car, Infrared Thermal Camera from Non Contact Human Body Temperature Monitoring Thermal Screening Camera for Airport Railway Bank Hospital Metro
Specification | Detector | VOx uncooled thermal FPA |
Resolution | 384x288 | |
Pixel size | 17pm | |
NETD | <40mK @25°C, F#1.0 | |
Response range | 814m | |
Theraml | Polarity | Black hot/white hot |
Image | Palette | Up to 18 palettes |
Temperature | Measurement range | 0°C 60°C |
Measurement | Accuracy | ±0.5tD@ 33°C~42°C of target temperature (±0.3°C with blackbody) |
Software | Measurement mode | Intelligent human face tracking and measuring |
Function | Flux | >60 people/minute |
High temperature alarm | Pop out window, audible alarm, capture alarm | |
Power | Power supply | 9-26V DC |
Supply | Power protection | Reverse connection protection for typical power supply |
Typical consumption @25"C | <3W | |
Lens | Focal length | 9.7mm |
FOV(HxV) | 37.9°x28.7° | |
Connector | Network connector | RJ45 |
Network protocal | Ethernet/IP, TCP, UDP, SNTP, RTSP, HTTP, ICMP, SMTP, DHCP, UPnP, PPPOE | |
Ethernet | Control and transmiss video | |
Compression | Video compressing standard | H.264/H.265 |
standard | Video format | mp4, mov |
Alarm | Alarm function | H.264/H.265 |
Alarm output | mp4, mov | |
Physical | Weight | <700g |
character | Dimension | 87x73x233 (mm) |
Environment | Working temperature | -10°C~50°C |
Adaptation | Storage temperature | -40°C~+70°C |
Humidity | 595%, non-condensing | |
SDK | SDK | Supply Windows/Linux SDK and manual |
Spare parts | Spare parts | Cables |
Reference | Power supply | AC180~240V |
Blackbody | Max. power consumption | 260W |
Environment temperature | 0ºC~40ºC | |
Accuracy | ±0.2ºC@35ºC | |
Emissivity | 0.97±0.02 | |
Settling time | ≤5min | |
Temperature stability | ±(0.1ºC~0.3ºC)/h | |
Effective radiant surface | 100*80mm | |
Dimension(L×W×H) | 195*150*110mm |