China CE, TUV DC 2p 500V 800V 1000V 3p 1000V 20-40ka Power Lightning Surge Protector Protection Arrester Surge Protective Arrestor Device SPD, Find details about China DC SPD, DC1000V SPD from CE, TUV DC 2p 500V 800V 1000V 3p 1000V 20-40ka Power Lightning Surge Protector Protection Arrester Surge Protective Arrestor Device SPD
solar surge protector | XLSPD-PV | ||||
PV DC specific (LEC 6614-1/EN 61643-11) | |||||
Pole | 2 pole | 3 pole | |||
Electrical Parameter | |||||
Classifical test | II | II | |||
Uoc max (V DC) | 550 | 600 | 800 | 1000 | |
Uc (V DC) | 550 | 600 | 1000 | 1000 | |
In(8/20)us (KA) | 20 | 20 | |||
Imax(8/20)us (KA) | 40 | 40 | |||
Up (KV) | 2 | 3.8 | |||
Remote control and indication | |||||
Indication window | |||||
Plug-in module | |||||
Remote signal contact | |||||
Remote signal contact | Max working volt | 250V AC/30V DC | 250V AC/30V DC | ||
Max working amp 1A (250V/AC) | 1A (250V/AC) | 1A (250V/AC) | |||
1A (30V DC) | 1A (30V DC) | 1A (30V DC) | |||
Wiring & installation | |||||
Wiring capacity(mm2) | Hard wire | 4-25mm | 4-25mm | ||
Flexible wire | 4-16mm | 4-16mm | |||
Stripping length | 10 | 10 | |||
Terminal screwa | M5 | M5 | |||
Torque(Nm) | Main ciruit | 3.5 | 3.5 | ||
Remote signal contact | 0.25 | 0.25 | |||
Protection class | All profile | IP40 | IP40 | ||
Connection port | IP20 | IP20 | |||
Installation environment | No obvious shock and vibration | ||||
Altitude(m) | ≤ 2000 | ≤ 2000 | |||
Working temperature | 67 | 67 | |||
Relative humidity | 30%-90% | 30%-90% | |||
How to install | Install with H35-7.5/DIN35 stell mounting rail | ||||
Size(mm) (W*H*L) | W | 36 | 54 | ||
H | 90 | 90 | |||
L | 48.5 | 48.5 | |||
Weight (KG) | 0.28 | 0.42 |
Nominal PV system volt | 600V | 800V | 1000V |
MCOV(UCPV) | 700V DC | 1170V DC | 1200V DC |
Max system discharge Current (8/20us) (Imax) | 40KA | 40KA | 30KA |
Volt protection leve (UP) | ≤ 2.5KV | ≤ 4.0KV | ≤ 4.5KV |
Volt protection Level at 5KA (UP) | ≤ 2.0KV | ≤ 3.5KV | ≤ 4.0KV |
Integrate fuse breaking capacity/interrupting rating | 30KA/800V DC | 30KA/1000V DC | 30KA/1200V DC |
Technology | Short-circuit interruption (SCI) overcurrent protection | ||
Operating temperature range | -40 to +80 | ||
Nominal discharge current | 12.5KA | ||
Response time (ta) | <25ns | ||
Operating state/fault indication | Green (good) / Red (replace) | ||
Mounting | 35mm DIN Rail per EN 60715 | ||
Degree protection | IP20 | ||
capacity | 3 modules DIN 43880 |