China Medical Portable IV Syringe Pump Infusion Pump in Hospital ICU, Find details about China Vet Infusion Pump, Intravenous Infusion Pump from Medical Portable IV Syringe Pump Infusion Pump in Hospital ICU
Large LCD display, with backlight, suitable for working in various ambient light conditions. |
Disposable IV set of any brand is suitable for this pump |
Three working modes: Rate/Volumn |
Purge, KVO function |
Heating function is optional, suitable for infusing in winter or there is requirement for the medication temperature. |
Remote Controller makes operating more convenient. |
Central monitoring system is optional, the infusing status of each pump is displayed in real time at the central station through wireless transmission. |
Simple and convenient in operating, intuitive presence of working status. |
Audible and Visible alarms |
Alarm: Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle. |
Size: 140*157*220mm |
Net Weight: 1.8KGS |
Pump Type | Drip type infusion pump |
Pumping Way | Peristalic fingers |
Adjustable Drop Rate Range | 1-266 drop/min (step: 1 drop/min) |
Adjustable Volume Rate Range | 1~1200 ml/h (when 1~99.9 ml/h, step: 0.1 ml/h; greater than 99.9 ml/h, step: 1 ml/h) |
Flow Precision | Within 3% more or less(using the IV set appointed by the manufacturer or calibrated high quality IV set) |
Mechanical precision | within 2% more or less |
Purge Rate | 800 ml/h |
KVO Rate | 1 ml/h (1~300 ml/h) 3 ml/h (greater than 300 ml/h) |
Infusion Volume Range | 1 ml~9999.9 ml (step: 0.1 ml) |
Maximum Accumulated Volume | 9999.9 ml (step: 0.1 ml) |
Time Range | 1 min~9999 min (step: 1 min) |
Occlusion Alarm Threshold | High: 800 mmHg+-200 mmHg (106.7kPa+-26.7kPa) Medium: 500 mmHg+-100 mmHg (66.7kPa+-13.3kPa) Low: 300 mmHg+-100 mmHg (40.7kPa+-13.3kPa) |
Alarm | Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle. |
Air Bubble Detector Method | ultrasonic wave, sensitivity: more than or equal 25 μL |
Fuse | F1AL/250V ("F" indicate fast,"L" indicate low breaking capacity), 2 pcs (installed inside pump). |
Internal Battery | 11.1V rechargeable li-ion battery. Capacity:more than or equal 2000mAh; the pump can work more than 4 hours at the flow rate of 25 ml/h after charging for 8 hours (Medium rate specified by GB 9706.27-2005). |
Power | less than or equal 40VA |
Size | 140*157*220mm |
Weight | 1.8KG |
Environment Requirements | Transport Ambient Temperature: -30°C~+55°C Relative Humidity: 20%~95% (non-condensing) Atmosphere Pressure: 70kPa~106kPa Storage Ambient Temperature: -30°C~+55°C Relative Humidity: 20%~95% Atmosphere Pressure: 70kPa~106kPa Operation Ambient Temperature: +5~+40°C Relative Humidity: 20%~90% Atmosphere Pressure: 86kPa~106kPas |
Calibration function | disposable IV set of any brand is suitable for this pump |
Three working modes | Rate/Volumn |
Alarm | Infusion Complete, Empty, Faulty Signal, Misoperation, Occlusion, Door Open, Air Bubble, Low Battery, Setting Error, AC power off, Idle. |
infusion monitoring system (Optional), the status of each pump is displayed in real time at the central station through wireless transmission. |
4.3 inch color LCD display, with backlight, suitable for working in various ambient light conditions. |
Display time, battery, infusing status, mode, rate, target volume, accumulated volume, target volume, sound volume, pressure, department, bed No., I/V set, temperature of medication |
Packing and shipping
1. Package: double carton boxes
2. Port: Shenzhen China, Shanghai China
3. Delivery time: 3-5 working days after receipt of payment
Our Advantages:
Certificates:
Payment terms
T/T in advance, MoneyGram, Trade Assurance, Western Union, Escrow, Paypal, Credit Card!
Company information:
Exhibitions
Welcome to contact us!