Sup2h-PV DC 3 Phase 1000V Surge Arrester Solar PV Surge Protection Lightning Arrestor

China Sup2h-PV DC 3 Phase 1000V Surge Arrester Solar PV Surge Protection Lightning Arrestor, Find details about China Surge Arrester, Lightning Arrester from Sup2h-PV DC 3 Phase 1000V Surge Arrester Solar PV Surge Protection Lightning Arrestor

Model NO.
SUP2H-PV
Material
PA66
Certification
CCC, Ce, TUV
Brand
Suntree
Voltage
500VDC~1000VDC
Accessories
Remote Communication Terminal
Effect
Reliable, Stable
Color
Red, White, Yellow(According to Customer Needs)
Models
Complete
Quality Assurance
2 Years
Professional Manufacture
for 10years
Price
Competitive
Payment Item
T/T, L/C, Western Union, etc
Loading Port
Ningbo/Shanghai/Any Port
Trademark
SUNTREE/ OEM/ODM
Transport Package
Carton
Specification
500vdc/800vdc/1000vdc/1200vdc
Origin
China
HS Code
85354000
Model NO.
SUP2H-PV
Material
PA66
Certification
CCC, Ce, TUV
Brand
Suntree
Voltage
500VDC~1000VDC
Accessories
Remote Communication Terminal
Effect
Reliable, Stable
Color
Red, White, Yellow(According to Customer Needs)
Models
Complete
Quality Assurance
2 Years
Professional Manufacture
for 10years
Price
Competitive
Payment Item
T/T, L/C, Western Union, etc
Loading Port
Ningbo/Shanghai/Any Port
Trademark
SUNTREE/ OEM/ODM
Transport Package
Carton
Specification
500vdc/800vdc/1000vdc/1200vdc
Origin
China
HS Code
85354000
DC Spd Surge Protection Device DC500V 20KA-40KA


Sup2h-PV DC 3 Phase 1000V Surge Arrester Solar PV Surge Protection Lightning Arrestor


Solar system SPD, SPD solar system, solar SPD, DC surge protection device,

Surge Protection for Solar Photovoltaic (PV) System

The SUP4 series Surge Protection are designed to protect against lightning surge voltages in photovoltaic power supply networks.

These units must be installed in parallel on the DC networks to be protected and provide common and differential modes protection. The SUP4 series is available for the main operating voltages in photovoltaic: 1000 Vdc.

The use of SUP4 series Surge Protection is recommended at both ends of the DC power supply line (solar panel side and inverter/converter side),

Especially if the line routing is external and long. The electrical diagram of the SUP4 series is based on high energy PV equipped with specific thermal disconnectors and related failure indicators.

The SUP4 series is made with plug-in modules to allow a fast and easy maintenance in case of failure (disconnection from the DC network).
 

solar surge protector

SUP2-PV            

SUP4-PV

PV DC specific (LEC 6614-1/EN 61643-11)

Pole

2 pole

3 pole

Electrical Parameter

Classifical test

II

II

Uoc max (V DC)

500

900

Uc (V DC)

500

1000

In(8/20)us (KA)

20

20

Imax(8/20)us (KA)

40

40

Up (KV)

2.0

3.8

Remote control and indication

Indication window

Plug-in module

Remote signal contact

Remote signal contact

Max working volt

250V AC/30V DC

250V AC/30V DC

Max working amp 1A (250V/AC)

1A (250V/AC)

1A (250V/AC)

1A (30V DC)

1A (30V DC)

1A (30V DC)

Wiring & installation

Wiring capacity(mm2)

Hard wire

4-25

4-25

 

Flexible wire

4-16

4-16

Stripping length

10

10

Terminal screwa

M5

M5

Torque(Nm)

Main ciruit

3.5

3.5

Remote signal contact

0.25

0.25

Protection class

All profile

IP40

IP40

Connection port

IP20

IP20

Installation environment

No obvious shock and vibration

Altitude(m)

≤ 2000

≤ 2000

Working temperature

-3.0--+70

-3.0--+70

Relative humidity

30%-90%

30%-90%

How to install

Install with H35-7.5/DIN35 stell mounting rail

Size(mm) (W*H*L)

W

36

54

H

90

90

L

67.6

67.6

Weight (KG)

0.25

0.38


Specifications

Nominal PV system volt

600V

100V

1200V

MCOV(UCPV)

700V DC

1170V DC

1200V DC

Max system discharge Current (8/20us) (Imax)

40KA

40KA

30KA

Volt protection leve (UP)

≤ 2.5KV

≤ 4.0KV

≤ 4.5KV

Volt protection Level at 5KA (UP)

≤ 2.0KV

≤ 3.5KV

≤ 4.0KV

Integrate fuse breaking capacity/interrupting rating

30KA/1000V DC

30KA/1000V DC

30KA/1200V DC

Technology

Short-circuit interruption (SCI) overcurrent protection

Operating temperature range

-40 to +80

Nominal discharge current

12.5KA

Response time (ta)

<25ns

Operating state/fault indication

Green (good) / Red (replace)

Mounting

35mm DIN Rail per EN 60715

Degree protection

IP20

capacity

3 modules DIN 43880


Product Details Show
Sup2h-PV DC 3 Phase 1000V Surge Arrester Solar PV Surge Protection Lightning Arrestor

Application

Sup2h-PV DC 3 Phase 1000V Surge Arrester Solar PV Surge Protection Lightning Arrestor

SPD is used to protect all kinds of electrical equipment in the power system from lightning over-voltage, operation over-voltage, power frequency transient over-voltage impact damage to an electrical appliance

The electrical circuit or communication lines because of outside interference peak current or voltage suddenly, the surge protector can in a very short time conducting shunt, so as to avoid damage to other equipment surge in the loop Installed front of inverter input and back of inverter output Installed in Parallel the spd is installed in the electric circuit with parallel, the first to play a protective role, the response time in the 25 to 50 nanosecond

Advantage

First factory produce 1500V SPD, approved TUV certificate at EN50539-11 standard.
Every pole achieve 1500V, 1200V, 1000V, 500V.
PPT material cover. Anti flame.
Use Longke chip from Taiwan. Material Zinc oxide.
With specific thermal disconnects and failure indicator(visual indicator/ optional): green-good, red-replace
Remote control: with signal contact
Plug-in module
Life: 50 times
Sup2h-PV DC 3 Phase 1000V Surge Arrester Solar PV Surge Protection Lightning Arrestor
Company Information
Sup2h-PV DC 3 Phase 1000V Surge Arrester Solar PV Surge Protection Lightning Arrestor



FAQ

Q:When I can receive quotation and detail information after send the enquiry?
A: Reply will be sent in 24hours.

Q:What's the difference between you and other suppliers?
A: We have our own design box with PC/ABS material.

Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.

Q:Can I get a sample for test before place order?
A:Of course!

Q:How's the delivery?Because I really need them is urgently?
A: Samples cost 5-7 days. Bulk order cost 12-15 days.

Q: If i want to release order, what's the payment method you accept ?
A: We accept T/T, Paypal, Western union, L/C, Trade Assurance.