China 7kw Inverter Generator Hibrid Ongrid Solar Inverter 1kw 700W 1000W 2000W 3000W 4000W 5000W 6000W 8kw 9kw, Find details about China Inverter Generator, Ongrid Solar Inverter 1kw from 7kw Inverter Generator Hibrid Ongrid Solar Inverter 1kw 700W 1000W 2000W 3000W 4000W 5000W 6000W 8kw 9kw
Model | R5-3K-S2 | R5-4K-S2 | R5-5K-S2 | R5-6K-S2 | R5-7K-S2 | R5-8K-S2 |
Input(DC) | ||||||
Max.PV Array Power [Wp]@STC | 4500 | 6000 | 7500 | 9000 | 10500 | 12000 |
Max. DC Voltage [V] | 600 | |||||
MPPT Voltage Range [V] | 90-550 | |||||
Nominal DC Voltage[V] | 360 | |||||
Start Voltage [V] | 100 | |||||
Min. DC Voltage [V] | 80 | |||||
Max. DC Input Current [A] | 12.5/12.5 | 25/12.5 | ||||
Number of DC Connection Sets per MPPT | 1/1 | 2/1 | ||||
Number of MPPT | 2 | |||||
DC Switch | Integrated | |||||
Output (AC) | ||||||
Rated AC Power [W] | 3000 | 4000 | 5000*1 | 6000 | 7000 | 8000 |
Max. AC Power*1[VA] | 3300 | 4400 | 5500 | 6000 | 7700 | 8000 |
Rated AC Current [A]@230Vac | 13.1 | 17.4 | 21.8*1 | 26.1 | 30.5 | 34.8 |
Max. AC Current [A] | 14.4 | 19.2 | 24 | 26.1 | 33.5 | 34.8 |
Nominal AC Voltage/ Range [V] | 220,230,240/180-280 | |||||
Grid Frequency/ Range [Hz] | 50,60/45-55,55-65 | |||||
Power Factor [cos φ] | 0.8 leading~0.8 lagging | |||||
Total Harmonic Distortion [THDi] | < 2%(at nominal power) | |||||
Feed-in | L+N+PE | |||||
Efficiency | ||||||
Max. Efficiency | 97.8% | 98.0% | 98.1% | 98.2% | 98.2% | 98.3% |
Euro Efficiency | 97.2% | 97.5% | 97.6% | 97.6% | 97.7% | 97.8% |
MPPT Accuracy | >99.9% | |||||
Protection | ||||||
Internal Over-voltage Protection | Integrated | |||||
DC Insulation Monitoring | Integrated | |||||
DC Surge Protection | Integrated | |||||
Grid Monitoring | Integrated | |||||
AC Short Circuit Current Protection | Integrated | |||||
AC Grounding Detection | Integrated | |||||
GFCI Monitoring | Integrated | |||||
DCI Monitoring | Integrated | |||||
AC Surge Protection | Integrated | |||||
Thermal Protection | Integrated | |||||
Anti-island protection monitoring | AFD | |||||
Interface | ||||||
DC Connection | MC4 | |||||
AC Connection | Plug-in connector | Terminal Block | ||||
Human Machine Interface | LED+(bluetooth/Wi-Fi+APP) | |||||
Communication Port | RS232(USB joints)+RS485(RJ45 crystal joints) | |||||
Communication Mode | Wi-Fi/GPRS/4G(Optional) | |||||
General Data | ||||||
Topology | Transformerless | |||||
Consumption at Night [W] | <0.2 | |||||
Consumption at Standby [W] | 6 | |||||
Operating Temperature Range | -40°C to +60°C (running in reduced load condition when the temperature is above 45°C) | |||||
Cooling Method | Natural Convection | |||||
Ambient Humidity | 0-100% Non-condensing | |||||
Altitude | 4000m(>3000m power derating) | |||||
Noise [dBA] | <25 | |||||
Ingress Protection | IP65 | |||||
Mounting | Rear Panel | |||||
Dimensions [H*W*D][mm] | 389*367*143 | 429*418*177 | ||||
Weight [kg] | 12.2 | 18 | ||||
Standard Warranty [Year] | 5 (standard)/10/15/20/25 (Optional) | |||||
Applicable Standard | IEC62109-1/2,IEC61000-6-1/2/3/4,EN50438,C10/C11,IEC62116,IEC61727,RD1699,UNE 206006, UNE 206007,CEI 0-21,AS4777.2,NBR 16149, NBR 16150,VDE-AR-N 4105 | |||||
Remarks: *1 According to VDE - ARN - N 4105, Rated AC Power for R5-5K-S2 is 4600VA; According to AS4777, Rated AC Power for R5-5K-S2 is 4999VA. *2 According to C10/C11, Max. AC Power = Rated AC Power *3 According to VDE - ARN - N 4105, Rated AC Current for R5-5K-S2 is 20A; According to AS4777, Rated AC Current for R5-5K-S2 is 21.7A. |