China Grid Tied Solar Inverter 4kw with MPPT Single Phase Inverter for Grid Tied Solar Power System Use 4000W 5kw 6kw 7kw 8kw, Find details about China Pure Sine Wave Solar Inverter 4kw, Solar System Inverter 4kw with MPPT from Grid Tied Solar Inverter 4kw with MPPT Single Phase Inverter for Grid Tied Solar Power System Use 4000W 5kw 6kw 7kw 8kw
Model | R5-3K-S2 | R5-4K-S2 | R5-5K-S2 | R5-6K-S2 | R5-7K-S2 | R5-8K-S2 |
Input(DC) | ||||||
Max.PV Array Power [Wp]@STC | 4500 | 6000 | 7500 | 9000 | 10500 | 12000 |
Max. DC Voltage [V] | 600 | |||||
MPPT Voltage Range [V] | 90-550 | |||||
Nominal DC Voltage[V] | 360 | |||||
Start Voltage [V] | 100 | |||||
Min. DC Voltage [V] | 80 | |||||
Max. DC Input Current [A] | 12.5/12.5 | 25/12.5 | ||||
Number of DC Connection Sets per MPPT | 1/1 | 2/1 | ||||
Number of MPPT | 2 | |||||
DC Switch | Integrated | |||||
Output (AC) | ||||||
Rated AC Power [W] | 3000 | 4000 | 5000*1 | 6000 | 7000 | 8000 |
Max. AC Power*1[VA] | 3300 | 4400 | 5500 | 6000 | 7700 | 8000 |
Rated AC Current [A]@230Vac | 13.1 | 17.4 | 21.8*1 | 26.1 | 30.5 | 34.8 |
Max. AC Current [A] | 14.4 | 19.2 | 24 | 26.1 | 33.5 | 34.8 |
Nominal AC Voltage/ Range [V] | 220,230,240/180-280 | |||||
Grid Frequency/ Range [Hz] | 50,60/45-55,55-65 | |||||
Power Factor [cos φ] | 0.8 leading~0.8 lagging | |||||
Total Harmonic Distortion [THDi] | < 2%(at nominal power) | |||||
Feed-in | L+N+PE | |||||
Efficiency | ||||||
Max. Efficiency | 97.8% | 98.0% | 98.1% | 98.2% | 98.2% | 98.3% |
Euro Efficiency | 97.2% | 97.5% | 97.6% | 97.6% | 97.7% | 97.8% |
MPPT Accuracy | >99.9% | |||||
Protection | ||||||
Internal Over-voltage Protection | Integrated | |||||
DC Insulation Monitoring | Integrated | |||||
DC Surge Protection | Integrated | |||||
Grid Monitoring | Integrated | |||||
AC Short Circuit Current Protection | Integrated | |||||
AC Grounding Detection | Integrated | |||||
GFCI Monitoring | Integrated | |||||
DCI Monitoring | Integrated | |||||
AC Surge Protection | Integrated | |||||
Thermal Protection | Integrated | |||||
Anti-island protection monitoring | AFD | |||||
Interface | ||||||
DC Connection | MC4 | |||||
AC Connection | Plug-in connector | Terminal Block | ||||
Human Machine Interface | LED+(bluetooth/Wi-Fi+APP) | |||||
Communication Port | RS232(USB joints)+RS485(RJ45 crystal joints) | |||||
Communication Mode | Wi-Fi/GPRS/4G(Optional) | |||||
General Data | ||||||
Topology | Transformerless | |||||
Consumption at Night [W] | <0.2 | |||||
Consumption at Standby [W] | 6 | |||||
Operating Temperature Range | -40°C to +60°C (running in reduced load condition when the temperature is above 45°C) | |||||
Cooling Method | Natural Convection | |||||
Ambient Humidity | 0-100% Non-condensing | |||||
Altitude | 4000m(>3000m power derating) | |||||
Noise [dBA] | <25 | |||||
Ingress Protection | IP65 | |||||
Mounting | Rear Panel | |||||
Dimensions [H*W*D][mm] | 389*367*143 | 429*418*177 | ||||
Weight [kg] | 12.2 | 18 | ||||
Standard Warranty [Year] | 5 (standard)/10/15/20/25 (Optional) | |||||
Applicable Standard | IEC62109-1/2,IEC61000-6-1/2/3/4,EN50438,C10/C11,IEC62116,IEC61727,RD1699,UNE 206006, UNE 206007,CEI 0-21,AS4777.2,NBR 16149, NBR 16150,VDE-AR-N 4105 | |||||
Remarks: *1 According to VDE - ARN - N 4105, Rated AC Power for R5-5K-S2 is 4600VA; According to AS4777, Rated AC Power for R5-5K-S2 is 4999VA. *2 According to C10/C11, Max. AC Power = Rated AC Power *3 According to VDE - ARN - N 4105, Rated AC Current for R5-5K-S2 is 20A; According to AS4777, Rated AC Current for R5-5K-S2 is 21.7A. |
Our Services: