China Service Electric Cable, Electric Cable, ABC Cable, Electrical Wire Size, Secondary Cable, Find details about China Service Electric Cable, Electric Cable from Service Electric Cable, Electric Cable, ABC Cable, Electrical Wire Size, Secondary Cable
=========================================================
Professional OEM manufacturer
Top ten cable manufactuer in China
Leading ESP cable manufacture , largest Rubber cable manufacturer in China.
With UL,TUV,KEMA,CE,BV,PSB,SABA certifications
With TUV TYPE TESTING REPORT
With ISO9001,ISO18001,OHSAS18001 syetem certifications
=========================================================
We produce the ABC Electric Cable used for overhead line(duplex, triplex, quadruplex) in IEC standard, ASTM ANSI/ICEA S-76-474 NF C 33-209 standard.
LV ABC cable(Aerial Bundle cable) with AAAC conductor
Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, Duplex, Triplex, Quadruplex.
Service Drop Cable(ABC CABLE) are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
TYPE ONE Service Drop wire ABC CABLE
ABC CABLE -aerial bundle cable :are mainly used for electric power transmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
Applications:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
Construction
Phase Conductor construction:The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.
Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:
Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded
Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded
Aluminum alloy 6201-T81, concentric-lay-stranded
Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)
Alternatively, black linear low-density polyethylene (LLDPE) insulation with a 75°C temperature rating is available upon request.
Standards
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
Duplex Service Drop-Aluminum Conductor
Code | Phase Conductor | Bare Neutral Messenger | Weight Per | Rating(Amps) | ||||||
Name | 1000 ft(lbs) | |||||||||
Size | Strand | Insulation | Size | *Strand | Breaking | XLP | POLY | XLP | POLY | |
AWG | thickness | AWG | strength | |||||||
(mls) | (lbs) | |||||||||
AAC | ||||||||||
Pekingese | 6 | solid | 45 | 6 | 7/w | 563 | 63.5 | 61.7 | 70 | 70 |
Collie | 6 | 7/w | 45 | 6 | 7/w | 563 | 66.8 | 63.1 | 70 | 70 |
Dachshund | 4 | solid | 45 | 4 | 7/w | 881 | 95.5 | 93.4 | 90 | 90 |
Spaniel | 4 | 7/w | 45 | 4 | 7/w | 881 | 101 | 95.4 | 90 | 90 |
Doberman | 2 | 7/w | 45 | 2 | 7/w | 1,350 | 153 | 145.7 | 120 | 120 |
Malemute | 1/0 | 19/w | 60 | 1/0 | 7/w | 1,990 | 243 | 234.2 | 160 | 160 |
ACSR NEUTRAL-MESSENGER | ||||||||||
Setter | 6 | solid | 45 | 6 | '6/1 | 1.19 | 75 | 73.2 | 70 | 70 |
Shepherd | 6 | 7/w | 45 | 6 | '6/2 | 1.19 | 78.3 | 74.6 | 70 | 70 |
Eskimo | 4 | solid | 45 | 4 | '6/3 | 1.86 | 114 | 111.6 | 90 | 90 |
Terrier | 4 | 7/w | 45 | 4 | '6/4 | 1.86 | 119 | 113.6 | 90 | 90 |
Chow | 2 | 7/w | 45 | 2 | '6/5 | 2.85 | 182 | 174.7 | 120 | 120 |
Bull | 1/0 | 19/w | 60 | 1/0 | '6/6 | 4.38 | 289 | 280.3 | 160 | 160 |
6201 ALLOY NEUTRAL-MESSENGER | ||||||||||
Chihuahua | 6 | solid | 45 | 6 | 7/w | 1,110 | 67.6 | 65.8 | 70 | 70 |
Vizsla | 6 | 7/w | 45 | 6 | 7/w | 1,110 | 70.9 | 67.2 | 70 | 70 |
Harrier | 4 | solid | 45 | 4 | 7/w | 1,760 | 102 | 99.9 | 90 | 90 |
Whippet | 4 | 7/w | 45 | 4 | 7/w | 1,760 | 107 | 101.9 | 90 | 90 |
Schnauzer | 2 | 7/w | 45 | 2 | 7/w | 2,800 | 163 | 156.2 | 120 | 120 |
Heeler | 1/0 | 19/w | 60 | 1/0 | 7/w | 4,460 | 259 | 250.8 | 160 | 160 |
Code | Phase Conductor | Bare Neutral Messenger | Weight Per | Ampacity (Amps) | |||||||
Name | 1000 ft(lbs) | ||||||||||
Size | Stranding | Insulation | Size | Stranding | Breaking | XLP | POLY | XLP | POLY | ||
AWG | thickness | AWG | strength | ||||||||
(mls) | (lbs) | ||||||||||
6201 ALLOY NEUTRAL-MESSENGER | |||||||||||
Minex | 6 | solid | 45 | 6 | 7 | 1,110 | 106.6 | 102.9 | 85 | 70 | |
Hippa | 6 | 7/w | 45 | 6 | 7 | 1,110 | 113.2 | 105.7 | 85 | 70 | |
Prawn | 4 | solid | 45 | 4 | 7 | 1,760 | 158.4 | 154.1 | 115 | 90 | |
Barnacles | 4 | 7/w | 45 | 4 | 7 | 1,760 | 168.3 | 158.2 | 115 | 90 | |
Shrimp | 2 | 7/w | 45 | 2 | 7 | 2,800 | 253.7 | 239.7 | 150 | 120 | |
Gammarus | 1/0 | 7/w | 60 | 1/0 | 7 | 4,460 | 411.7 | 386 | 205 | 160 | |
Leda | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 402.7 | 386 | 205 | 160 | |
Dungenese | 2/0 | 7/w | 60 | 2/0 | 7 | 5,390 | 506.8 | 476.3 | 235 | 185 | |
Cyclops | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 495.3 | 476.3 | 235 | 185 | |
Flustra | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 611.4 | 589.1 | 275 | 215 | |
Lepas | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 757.1 | 730.5 | 315 | 245 | |
6201 ALLOY REDUCED NEUTRAL-MESSENGER | |||||||||||
Artemia | 4 | solid | 45 | 6 | 7 | 1,110 | 141.4 | 137.1 | 115 | 90 | |
Crab | 4 | 7/w | 45 | 6 | 7 | 1,110 | 151.3 | 141.2 | 115 | 90 | |
Solaster | 2 | 7/w | 45 | 4 | 7 | 1,760 | 226.6 | 212.6 | 150 | 120 | |
Sandcrab | 1/0 | 7/w | 60 | 2 | 7 | 2,800 | 368.8 | 343.1 | 205 | 160 | |
Echinus | 1/0 | 19/w | 60 | 2 | 7 | 2,800 | 358.8 | 343.1 | 205 | 160 | |
Crayfish | 2/0 | 7/w | 60 | 1 | 7 | 3,530 | 452.6 | 422.5 | 235 | 185 | |
Sipho | 2/0 | 19/w | 60 | 1 | 7 | 3,530 | 441 | 422.5 | 235 | 185 | |
Fulgar | 3/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 543.4 | 521.1 | 275 | 215 | |
Arca | 4/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 671.2 | 644.6 | 315 | 245 | |
AAC NEUTRAL-MESSENGER | |||||||||||
Haiotis | 6 | solid | 45 | 6 | 7 | 563 | 102.5 | 98.8 | 85 | 70 | |
Patella | 6 | 7/w | 45 | 6 | 7 | 563 | 109.1 | 101.6 | 85 | 70 | |
Fusus | 4 | solid | 45 | 4 | 7 | 881 | 151.9 | 147.6 | 115 | 90 | |
Oyster | 4 | 7/w | 45 | 4 | 7 | 881 | 161.8 | 151.7 | 115 | 90 | |
Clam | 2 | 7/w | 45 | 2 | 7 | 1,350 | 243.2 | 229.2 | 150 | 120 | |
Murex | 1/0 | 7/w | 60 | 1/0 | 7 | 1,990 | 395.1 | 369.4 | 205 | 160 | |
Purpura | 1/0 | 19/w | 60 | 1/0 | 7 | 1,990 | 386.1 | 369.4 | 205 | 160 | |
Nassa | 2/0 | 7/w | 60 | 2/0 | 7 | 2,510 | 485.8 | 455.3 | 235 | 185 | |
Melita | 3/0 | 19/w | 60 | 3/0 | 19 | 3,310 | 585.2 | 562.9 | 275 | 215 | |
Portunus | 4/0 | 19/w | 60 | 4/0 | 19 | 4,020 | 723.9 | 697.3 | 315 | 245 | |
Nannynose | 336.4 | 19/w | 80 | 336 | 19 | 6,146 | 1160 | 1118 | 420 | 325 | |
WITH FULL SIZE ACSR MESSENGER | |||||||||||
Paludina | 6 | solid | 45 | 6 | '6/1 | 1,190 | 114 | 113 | 85 | 70 | |
Voluta | 6 | 7/w | 45 | 6 | '6/1 | 1,190 | 120 | 113 | 85 | 70 | |
Whelk | 4 | solid | 45 | 4 | '6/1 | 1,860 | 169 | 165 | 115 | 90 | |
Periwinkle | 4 | 7/w | 45 | 4 | '6/1 | 1,860 | 176 | 172 | 115 | 90 | |
Conch | 2 | 7/w | 45 | 2 | '6/1 | 2,850 | 267 | 261 | 150 | 120 | |
Neritina | 1/0 | 7/w | 60 | 1/0 | '6/1 | 4,380 | 530 | 419 | 205 | 160 | |
Cenia | 1/0 | 19/w | 60 | 1/0 | '6/1 | 4,380 | 426 | 416 | 205 | 160 | |
Runcina | 2/0 | 7/w | 60 | 2/0 | '6/1 | 5,310 | 530 | 519 | 235 | 185 | |
Triton | 2/0 | 19/w | 60 | 2/0 | '6/1 | 5,310 | 526 | 514 | 235 | 185 | |
Cherrystone | 3/0 | 7/w | 60 | 3/0 | '6/1 | 6,620 | 656 | 643 | 250 | 200 | |
Mursia | 3/0 | 19/w | 60 | 3/0 | '6/1 | 6,620 | 650 | 638 | 250 | 200 | |
Razor | 4/0 | 7/w | 60 | 4/0 | '6/1 | 8,350 | 814 | 799 | 315 | 245 | |
Zuzara | 4/0 | 19/w | 60 | 4/0 | '6/1 | 8,350 | 805 | 792 | 315 | 245 | |
Limpet | 336.4 | 19/w | 80 | 336 | '6/1 | 8,680 | 1209 | 1167 | 420 | 325 | |
WITH ACSR REDUCED SIZE MESSENGER | |||||||||||
Scallop | 4 | Solid | 45 | 6 | '6/1 | 1,190 | 148 | 144 | 115 | 90 | |
Strombus | 4 | 7/w | 45 | 6 | '6/1 | 1,190 | 158 | 148 | 115 | 90 | |
Cockle | 2 | 7/ w | 45 | 4 | '6/1 | 1,860 | 233 | 227 | 150 | 120 | |
Janthina | 1/0 | 7/ w | 60 | 2 | '6/1 | 2,850 | 376 | 365 | 205 | 160 | |
Ranella | 1/0 | 19/ w | 60 | 2 | '6/1 | 2,850 | 372 | 362 | 205 | 160 |
Code | Phase Conductor | Bare Neutral Messenger | Weight Per | Rating(Amps) | ||||||
Name | 1000 ft(lbs) | |||||||||
Size | Strand | Insulation | Size | Strand | Breaking | XLP | POLY | XLP | POLY | |
AWG | thickness | AWG | strength | |||||||
(mls) | (lbs) | |||||||||
AAC NEUTRAL-MESSNGER | ||||||||||
Clydesdale | 4 | Solid | 45 | 4 | 7 | 881 | 208 | 201.8 | 100 | 80 |
Pinto | 4 | 7/w | 45 | 4 | 7 | 881 | 223 | 207.9 | 100 | 80 |
Mustang | 2 | 7/w | 45 | 2 | 7 | 1,350 | 333 | 312.6 | 135 | 105 |
Criollo | 1/0 | 19/w | 60 | 1/0 | 7 | 1,990 | 529 | 504.5 | 180 | 140 |
Percheron | 2/0 | 19/w | 60 | 2/0 | 7 | 2,510 | 649 | 620.5 | 205 | 160 |
Hanoverian | 3/0 | 19/w | 60 | 3/0 | 19 | 3,310 | 799 | 765.6 | 235 | 185 |
Oldenburg | 4/0 | 19/w | 60 | 4/0 | 19 | 4,020 | 986 | 946.7 | 275 | 210 |
Lippizaner | 336.4 | 19/w | 80 | 336.4 | 19 | 6,146 | 1,546 | 1,519.20 | 370 | 280 |
ACSR NEUTRAL-MESSNGER | ||||||||||
Morochuca | 6 | Solid | 45 | 6 | '6/1 | 1,190 | 152 | 147.4 | 75 | 60 |
Chola | 6 | 7/w | 45 | 6 | '6/1 | 1,190 | 162 | 151.7 | 75 | 60 |
Morgan | 4 | Solid | 45 | 4 | '6/1 | 1,860 | 226 | 220 | 100 | 80 |
Hackney | 4 | 7/w | 45 | 4 | '6/1 | 1,860 | 241 | 226.1 | 100 | 80 |
Palomino | 2 | 7/w | 45 | 2 | '6/1 | 2,850 | 362 | 342.6 | 135 | 105 |
Costena | 1/0 | 19/w | 60 | 1/0 | '6/1 | 4,380 | 575 | 550.6 | 180 | 140 |
Grullo | 2/0 | 19/w | 60 | 2/0 | '6/1 | 5,310 | 707 | 678.7 | 205 | 160 |
Suffolk | 3/0 | 19/w | 60 | 3/0 | '6/1 | 6,620 | 872 | 838.9 | 235 | 185 |
Appaloosa | 4/0 | 19/w | 60 | 4/0 | '6/1 | 8,350 | 1079 | 1039.2 | 275 | 210 |
Bronco | 336.4 | 19/w | 80 | 336.4 | '18/1 | 8,580 | 1613 | 1568.2 | 370 | 280 |
Gelding | 336.4 | 19/w | 80 | 4/0 | '6/1 | 8,350 | 1548 | 1494.3 | 370 | 280 |
6201 ALLOY NEUTRAL-MESSENGER | ||||||||||
Bay | 6 | Solid | 45 | 6 | 7 | 1,110 | 145 | 140 | 75 | 60 |
French Coach | 6 | 7/w | 45 | 6 | 7 | 1,110 | 155 | 144.3 | 75 | 60 |
German Coach | 4 | Solid | 45 | 4 | 7 | 1,760 | 214 | 208.3 | 100 | 80 |
Arabian | 4 | 7/w | 45 | 4 | 7 | 1,760 | 229 | 214.4 | 100 | 80 |
Belgian | 2 | 7/w | 45 | 2 | 7 | 2,800 | 344 | 323.1 | 135 | 105 |
Shetland | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 546 | 521.1 | 180 | 140 |
Thoroughbred | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 670 | 641.5 | 205 | 160 |
Trotter | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 825 | 791.8 | 235 | 185 |
Walking | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 1019 | 979.7 | 275 | 210 |
Cross Section of Conductor | Min.Nos. of Wires for Conductor | Insulation Thickness | Average Max. O.D.per Single-core | Max.Conductor Resistance at 20ºC | Min Insulated Resistance at Rated Working Temperature | Cable Tensile Breaking Force | |
(mm2) | (mm) | (mm) | (mm) | (Ω/km) | (MΩ.km) | ||
2x10 | 6 | 1 | 6.5x13.0 | 3.08 | 0.0067 | 0.67 | 1650 |
2x16 | 6 | 1.2 | 8.0x16.0 | 1.91 | 0.0065 | 0.65 | 2512 |
2x25 | 6 | 1.2 | 9.4x18.8 | 1.2 | 0.0054 | 0.54 | 3762 |
2x35 | 6 | 1.4 | 11.0x22.0 | 0.868 | 0.0054 | 0.54 | 5177 |
2x50 | 6 | 1.4 | 12.3x24.6 | 0.641 | 0.0046 | 0.46 | 7011 |
2x70 | 12 | 1.4 | 14.1x28.2 | 0.443 | 0.004 | 0.4 | 10354 |
2x95 | 15 | 1.6 | 16.5x33.0 | 0.32 | 0.0039 | 0.39 | 13727 |
2x120 | 15 | 1.6 | 18.1x36.2 | 0.252 | 0.0035 | 0.35 | 17339 |
2x150 | 15 | 1.8 | 20.2x40.4 | 0.206 | 0.0035 | 0.35 | 21033 |
2x185 | 30 | 2 | 22.5x45.0 | 0.164 | 0.0035 | 0.35 | 26732 |
2x240 | 30 | 2.2 | 25.6x51.2 | 0.125 | 0.0034 | 0.34 | 34679 |
4x10 | 6 | 1 | 6.5x26.0 | 3.08 | 0.0067 | 0.67 | 1650 |
4x16 | 6 | 1.2 | 8.0x32.0 | 1.91 | 0.0065 | 0.65 | 2512 |
4x25 | 6 | 1.2 | 9.4x37.6 | 1.2 | 0.0054 | 0.54 | 3762 |
4x35 | 6 | 1.4 | 11.0x44.0 | 0.868 | 0.0054 | 0.54 | 5177 |
4x50 | 6 | 1.4 | 12.3x49.2 | 0.641 | 0.0046 | 0.46 | 7011 |
4x70 | 12 | 1.4 | 14.1x56.4 | 0.443 | 0.004 | 0.4 | 10354 |
4x95 | 15 | 1.6 | 16.5x66.0 | 0.32 | 0.0039 | 0.39 | 13727 |
4x120 | 15 | 1.6 | 18.1x72.4 | 0.252 | 0.0035 | 0.35 | 17339 |
4x150 | 15 | 1.8 | 20.2x80.8 | 0.206 | 0.0035 | 0.35 | 21033 |
4x185 | 30 | 2 | 22.5x90.0 | 0.164 | 0.0035 | 0.35 | 26732 |
4x240 | 30 | 2.2 | 25.6x102.4 | 0.125 | 0.0034 | 0.34 | 3467 |
HeBei Huatong Wires&Cables Group Co.,ltd.
was established in 1993.Hebei Huatong Wires and Cables Group Co., Ltd covers an area more than 220,000 square meters, owning more than 420 sets manufacturing equipment and more than 250 sets of testing equipment or apparatus. Our annual production capacity is 3 billionYuan.Now there are more than 800 employers in our company, among which more than 150 are technicians. Our products are widely used in the field of electric power, coal, metallurgy, petrochemical industry, railway, national defense, construction, aviation and other national key projects.
We are top cable manufacture of rubber serious cables . Besides these,our submersible oil pump cable and shipboard cable are very influential in domestic, and, the traditional cables are also produced such as PVC power cables, XLPE power cables, ABC cables, wires, control cables, screened cables,communication cables, conductors.We are OEM for many USA, Europen, Australia cable company,70% of our products are exported, most customers are from developed countries. We got ISO,UL,TUV,KEMA,CE and many other certifications.
1.22 years production experience and 13 years export experience .
2.Products certification :UL,CE,BV,TUV,KEMA,PSB,SABS,ABS,NK,LR,KR,GL etc
3. OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7. Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.
=========================================================(1).When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price,please call us or tell us in your e-mail so that we will regard your inquiry priority.
(2).How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
(3).How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~5 days. You can use your own express account or prepay us if you do not have an account.
(4).What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order.The best record we keep is delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.