AV-2000b2 Medical Equipment Mobile Energy Recovery ICU Anesthesia Ventilator Machine

China AV-2000b2 Medical Equipment Mobile Energy Recovery ICU Anesthesia Ventilator Machine, Find details about China Ventilator Machine, Ventilator from AV-2000b2 Medical Equipment Mobile Energy Recovery ICU Anesthesia Ventilator Machine

Model NO.
AV-2000B2
Rate
2~99 Bpm
Ventilation Mode
Ippv, Sippv, Simv, Peep, Manual, Sigh
I:E
2:1~1:8
Trademark
WANROOEMED
Transport Package
Export Wooden Package
Specification
ISO, CE
Origin
Jiangsu, China (Mainland)
HS Code
94029000
Model NO.
AV-2000B2
Rate
2~99 Bpm
Ventilation Mode
Ippv, Sippv, Simv, Peep, Manual, Sigh
I:E
2:1~1:8
Trademark
WANROOEMED
Transport Package
Export Wooden Package
Specification
ISO, CE
Origin
Jiangsu, China (Mainland)
HS Code
94029000
AV-2000B2 Medical Equipment Mobile Energy Recovery ICU Anesthesia Ventilator Machine
AV-2000b2 Medical Equipment Mobile Energy Recovery ICU Anesthesia Ventilator Machine
AV-2000B2 is a multi-functional Ventilator, adopting pneumatic, electronic control and microcomputer technology. Imported components are utilized to guarantee stablility and reliabiligyt. With color screen(TEF) to display various measuringand configuration parameters, the ventilator suitable for respiratory treatment, applicable for medical, surgical and gynecological department, pediatrics department, first aid, ICU etc. Air source cen be conneted.

Ventilator
Display mode: High-definition 8.4" TFT color LCD screen display
Ventilation mode: IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH
Ventilation parameters: Tidal volume: 50~1500 ml Rate: 2~99 bpm SIMV rate: 2~20 bpm
I: E: 2: 1~1: 8 Inspiratory trigger pressure: -1.0~2.0kPa PEEP: 0~2.0 kPa
Pressure range: 1.0~6.0 kPa SIGH: 1.5 times the inspiratory time Inspiratory platform: 0~50%
Parameters for ventilation monitoring: Tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform
Monitoring of oxygen concentration: 21%-100%


Security Alarm System
Oxygen Concentration alarm: Upper limit setting range 50%~100% low limit setting range 15%~50%
Airway pressure alarm: Upper limit setting range 1.0~6.0 kPa low limit setting range 0.4~2.0 kPa
Per-minute ventilation volume alarm: Upper limit setting range 3.0~30L/min low limit setting range 1.0~10L/min
Sustained high-pressure alarm: It will give alarm when stress have consistently been higher than 2.5 kPa
Suffocation alarm: It will give sound and light alarm if there is no tidal volume input for 15 seconds
Power alarm
Power: AC 220V± 10% 50Hz± 1Hz UPS, Storage battery


Details:
AV-2000b2 Medical Equipment Mobile Energy Recovery ICU Anesthesia Ventilator Machine

Company Information:
AV-2000b2 Medical Equipment Mobile Energy Recovery ICU Anesthesia Ventilator Machine
AV-2000b2 Medical Equipment Mobile Energy Recovery ICU Anesthesia Ventilator Machine