An50710 330V/100A/30kw DC Power Supply

China An50710 330V/100A/30kw DC Power Supply, Find details about China 35V DC Power Supply, 60V DC Power Supply from An50710 330V/100A/30kw DC Power Supply

Model NO.
AN50710
Brand
Ainuo
After-Sales Service
Provide After-Sales Service
Manufacturer
Yes
Working Mode
Cc, CV
Voltage
35V, 60V, 80V, 120V, 150V, 330V, 630V, etc
Power
6kw, 9kw, 15kw, 30kw, etc
Communication Port
RS232, Optional RS485
Protection
Otp/Ovp/OPP/SCP/Rvp/Ssp/Oop/Hwp/Swp
Applications
Motor, Electrical Tool, Automobile, DC Switch, etc
Trademark
Ainuo
Transport Package
Wooden Case
Specification
W*H*D: 480*225*620mm or larger
Origin
Jinan
Model NO.
AN50710
Brand
Ainuo
After-Sales Service
Provide After-Sales Service
Manufacturer
Yes
Working Mode
Cc, CV
Voltage
35V, 60V, 80V, 120V, 150V, 330V, 630V, etc
Power
6kw, 9kw, 15kw, 30kw, etc
Communication Port
RS232, Optional RS485
Protection
Otp/Ovp/OPP/SCP/Rvp/Ssp/Oop/Hwp/Swp
Applications
Motor, Electrical Tool, Automobile, DC Switch, etc
Trademark
Ainuo
Transport Package
Wooden Case
Specification
W*H*D: 480*225*620mm or larger
Origin
Jinan
 
Product Description

The AN50 series DC power supply adopts high-frequency PWM control and phase-shifted full-bridge conversion, fast dynamic response, strong overcurrent capability, low output ripple, featuring compact, light, quiet, high efficiency, simple operation and cost-effective. It can be used for manufacturing, testing and maintenance of electronic equipment such as motors, power tools, automotive electronics, switching coils and DC switches, aircraft and airborne equipment, radar, navigation, etc., as well as industrial and mining enterprises, colleges and universities laboratories, research institute, etc.

Features:

Work mode: CV, CC;
Use high frequency PWM and full-bridge convert technique to achieve high efficiency;
High power density design, standard case, wide application; 
LCD display, convenient for operation;
10 setting and quick recall groups;
Exceptional output stability. Source voltage effect<0.2%, Load effect<0.3%, Temperature drifts <0.4%, time varying drifts <0.3%;
Output voltage drop compensation, ensure the voltage accuracy under big current;
Providing RS232(standard) ,GPIB(optional), suitable for remote control;
Protect function: output short circuit, output over current, output limit current, over heat, input under voltage, input phase lack protection, sense terminal over compensation protection, sense terminal reverse connection protection.
Sequence test: 5 groups, 10 steps per group, 3000 cycles.
Analog interface (optional): start, stop, alarm, 0-5V/0-10V or 4-20mA analog control output.
Detailed Photos
An50710 330V/100A/30kw DC Power SupplyAn50710 330V/100A/30kw DC Power Supply
Product Parameters
      
ModelAN50402S(F)
AN50402T(F)
AN50403S(F)
AN50403T(F)
AN50405(F)AN50410(F) 
InputSingle phase:220V±22V,50Hz±5Hz
(3-phase 3-wire: 380V±40V,50Hz±5Hz)
3-phase 3-wire: 380V±40V,50Hz±5Hz 
OutputVoltage 0V-35V 
Current 0-200A 0-300A 0-500A 0-1000A 
Power 0-6kW 0-9kW 0-15kW 0-30kW 
Display Mode LCD display,4digits 
Testing AccuracyVoltage≤±0.5%(full scale value)(15V-35V):≤±1%(Reading);(0-15V):≤±1%(Reading)±1V   
Current≤±0.5%(full scale value)≤±1%(Reading +range) 
Ripple and Noise 20Hz-20MHzVrms 120mV 160mV 
Vpp 500mV 800mV 
EffectSource voltage effect±0.1%;Load effect:±0.2% 
Over load105%<Rated current≤110%,the output will be stopped within 5s;
Rated current>110%,the output will be stopped immediately;
105%<Rated current≤200%,the output will be stopped within 5s;Rated current>200%,the output will be stopped immediately; 
Protection Input phase loss protection (three-phase), input overvoltage and undervoltage, output overvoltage and undervoltage, overcurrent, overheat, short circuit protection, current limiting protection, s-terminal over compensation protection, s-terminal anti connection protection 
Transient response timeMeet the requirements of GJB572A Figure 13≤10ms 
Max output voltage drop compensation 4V 
Communication RS232(Standard)/RS485(Optional) 
Memory 10 groups of memory storage, power down memory function 
List test function5setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times5setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times(Optional) 
Analog interface(optional)Start,stop,alarm,0-5V/ 0-10V or 4-20m analog control outputNone 
EnvironmentTemperature:0~40ºC;Humidity:20~90%RH 
Dimension W×H×D(mm)  480×225×620 440×600×660540×1230×670 
Weight 55kg 90kg180kg 
Model AN50502S(F)
  AN50502T(F)
 AN50503S(F)
AN50503T(F)
AN50505(F)AN50510(F)
InputSingle phase:220V±22V,50Hz±5Hz
(3-phase 3-wire: 380V±40V,50Hz±5Hz)
3-phase 3-wire: 380V±40V,50Hz±5Hz
OutputVoltage 0V-60V
Current 0-100A 0-150A 0-250A 0-500A
Power 0-6kW 0-9kW 0-15kW 0-30kW
Display Mode LCD display,4 digits
Testing AccuracyVoltage≤±0.5%(full scale value)(15V-60V):≤±1%(reading value);(0-15V):≤±1%(reading value)±1V  
Current≤±0.5%(full scale value)≤±1%(reading value + range)
Ripple and Noise 20Hz-20MHzVrms180mV280mV
Vpp750mV1200mV
EffectSource voltage effect:±0.2%;Load effect:±0.2%
Over load105%<Rated current≤110%,the output will be stopped within 5s;
Rated current>110%,the output will be stopped immediately;
105%<Rated current≤200%,the output will be stopped within 5s;
Rated current>200%,the output will be stopped immediately;
ProtectionInput phase loss protection (three-phase), input overvoltage and undervoltage, output overvoltage and undervoltage, overcurrent, overheat, short circuit protection, current limiting protection, s-terminal over compensation protection, s-terminal anti connection protection
Transient response timeMeet the requirements of GJB572A Figure 13≤10ms
Max output voltage drop compensation 4V
Communication RS232(Standard)/RS485(Optional)
Memory10 groups of memory storage, power down memory function
List test function 5 setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times5setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times(Optional)
Analog interface(optional)Start,stop,alarm,0-5V/ 0-10V or 4-20m analog control outputNone
EnvironmentTemperature 0~40ºC;Humidity 20~90%RH
Dimension W×H×D(mm) 480×225×620 440×600×660540×1230×670
Weight 55kg 90kg 180kg
 
ModelAN50602S(F) 
(AN50602T(F))
AN50603S(F) 
(AN50603T(F))
AN50605(F) AN50610(F)
InputSingle phase:220V±22V,50Hz±5Hz
(3-phase 3-wire:380V±40V,50Hz±5Hz)
3-phase 3-wire:380V±40V,50Hz±5Hz
OutputVoltage 0V-120V
Current 0-50A 0-75A 0-125A 0-250A
Power 0-6kW 0-9kW 0-15kW 0-30kW
Display Mode LCD display,4 digits
Testing AccuracyVoltage≤±0.5%(40V-120V):≤±1%(Reading);(1V-40V):≤±1%(Reading)±1V  
Current≤±0.5%≤±1%(Reading+Range)
Ripple and Noise 20Hz-20MHzVrms 200mV 350mV
Vpp 800mV 1200mV
EffectSource voltage effect:±0.2%;Load effect:±0.2%
Over load105%<Rated current≤110%,the output will be stopped within 5s;
Rated current>110%,the output will be stopped immediately;
105%<Rated current≤200%,the output will be stopped within 5s;
Rated current>200%,the output will be stopped immediately;
100%<Rated current≤125%,the output will be stopped within 30s;
Rated current>125%,the output will be stopped immediately;
Protection Input phase loss protection (three-phase), input overvoltage and undervoltage, output overvoltage and undervoltage, overcurrent, overheat, short circuit protection, current limiting protection, s-terminal over compensation protection, s-terminal anti connection protection
Transient response time Meet the requirements of GJB572A Figure 13  ≤10ms
Max output voltage drop compensation 4V
Communication RS232(Standard)/RS485(Optional)
Memory10 groups of memory storage, power down memory function
List test function 5 setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times5setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times(Optional)
Analog interface(optional)Start,stop,alarm,0-5V/ 0-10V or 4-20m analog control output
Environment Temperature :0ºC-40ºC,Humidity :10-95%
Dimension W×H×D(mm)  480×225×620 440×600×660550×1200×660
Weight 55kg 90kg 240kg
 
Model AN50702S(F)  AN50703S(F) AN50705(F) AN50710(F)
InputSingle phase:220V±22V,50Hz±5Hz3-phase 3-wire:380V±40V,50Hz±5Hz
OutputVoltage 0V-330V
Current 0-20A 0-30A 0-50A 0-100A
Power 0-6kW 0-9kW 0-15kW 0-30kW
Display mode LCD display,4 digits
Testing AccuracyVoltage(100V-330V):≤±1(Reading)%;(3V-100V):≤±1%(Reading)±1V  
Current≤±1%(Reading+Range)
Ripple and Noise 20Hz-20MHzVrms 300mV 350mV
Vpp 900mV 900mV
EffectSource voltage effect:±0.2%;Load effect:±0.2%
Over load105%<Rated current≤110%,the output will be stopped within 5s;
Rated current>110%,the output will be stopped immediately;
100%<Rated current≤125%,the output will be stopped within 30s;
Rated current>125%,the output will be stopped immediately;
Protection Input phase loss protection (three-phase), input overvoltage and undervoltage, output overvoltage and undervoltage, overcurrent, overheat, short circuit protection, current limiting protection, s-terminal over compensation protection, s-terminal anti connection protection
Transient response time Meet the requirements of GJB572A Figure 13  ≤10ms
Max output voltage drop compensation15V
CommunicationRS232(Standard)/RS485(Optional)
Memory10 groups of memory storage, power down memory function
List test function 5 setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times5setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times(Optional)
Analog interface(optional)Start,stop,alarm,0-5V/ 0-10V or 4-20m analog control output
EnvironmentTemperature:0~40ºC;Humidity :20~90%RH
Dimension W×H×D(mm)441×177.8×550550×1200×660
Weight50kg 240kg
 
Model AN50805(F)AN50810(F)
Input 3-phase 3-wire:380V±40V,50Hz±5Hz
OutputVoltage 0-630V
Current 0-25A 0-50A
Power 0-15kW 0-30kW
 Display mode LCD display,4 digits
 Testing AccuracyVoltage(100V-630V):≤±1%(Reading);(6V-100V):≤±1%(Reading)±1V 
Current ≤±1%(Reading+Range)
 Ripple and Noise 20Hz-20MHzVrms 350mV
Vpp 900mV
Effect Source voltage effect:±0.2%;Load effect:±0.2%
Over load100%<Rated current≤125%,the output will be stopped within 30s;
Rated current>125%,the output will be stopped immediately;
Protection Input phase loss protection (three-phase), input overvoltage and undervoltage, output overvoltage and undervoltage, overcurrent, overheat, short circuit protection, current limiting protection, s-terminal over compensation protection, s-terminal anti connection protection
Transient response time Meet the requirements of GJB572A Figure 13  ≤10ms
Max output voltage drop compensation 15V
Communication RS232(Standard)/RS485(Optional)
Memory10 groups of memory storage, power down memory function
List test function(Optional)5 setting groups and 10 steps sequence,3 working mode for every step,max cycle 3000 times
Analog interface(optional)Start,stop,alarm,0-5V/ 0-10V or 4-20m analog control output
EnvironmentTemperature:0~40ºC;Humidity:20~90%RH
Dimension W×H×D(mm) 550×1200×660
Weight 240kg
Company Profile
An50710 330V/100A/30kw DC Power SupplyAn50710 330V/100A/30kw DC Power Supply