China 6kw off Grid Solar Inverter with 60A 120A MPPT Solar Inverter, Find details about China 1.5kw Hybrid Solar Inverter, 5kw 48VDC 230VAC Hybrid off Grid Solar Inverter from 6kw off Grid Solar Inverter with 60A 120A MPPT Solar Inverter
Model | GS1000W | GS1500W | GS2000W | GS3000W | |
AC Input | Nominal Power | 1000W | 1500W | 2000W | 3000W |
Input Voltage Waveform | Sinusoidal (utility or generator) | ||||
Nominal input Voltage | 120/230VAC | ||||
Low Line Disconnect | 85Vac±4%(Normal) or 80Vac±4% (Wide) for 120V 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V | ||||
High Line Disconnect | 136Vac±4%(Normal) or 140Vac±4%(Wide) for 120V 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V | ||||
Max AC input Voltage | 120V for Max150V, 230V for Max270V | ||||
Frequency | 50Hz:41-54Hz, 60Hz:51-64Hz | ||||
AC output | Output Voltage Waveform | Sine wave | |||
Power Factor | 0.9~1.0 | ||||
Nominal Output Voltage (V) | LV:120Vac ±10%rms, HV:230Vac ±10%rms | ||||
Nominal Output Frequency (Hz) | 50Hz ± 0.3Hz, 50Hz ± 0.3Hz | ||||
Solar charger | Rated Charge Current | 40A | 60A | ||
PV Input Voltage range | 15VDC-40VDC for 12VDC, 30VDC-55VDC for 24VDC, 60-110VDC for 48V | ||||
Max.PV open circuit array voltage | 12V for 40Vdc, 24V for 55Vdc, 48V for 110Vdc | ||||
Charger mode | MPPT | ||||
PV Low Voltage Re-connect | PV≥Bat.V+3V | ||||
PV Low Voltage Disconnect | PV<=Bat.V | ||||
Efficiency | ≥97% | ||||
AC Charger | Nominal Charger Current | 35A/50A/70A/90A(According to the inverter model) | |||
5 stages adjustable charging current | |||||
Over charge Protection | Bat.V≥15.5VDC for 12V battery, Bat.V≥31.0VDC for 24V battery , Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s | ||||
Efficiency | Efficiency(Battery Mode) | ≥87% | |||
Efficiency (Line Mode) | >98% | ||||
Battery Voltage | Nominal DC input Voltage | 12/24/48VDC | |||
Low Battery Alarm | 10.5VDC±0.3VDC for 12VDC | ||||
21VDC±0.6VDC for 24VDC | |||||
42VDC±1.2VDC for 48VDC | |||||
High DC input Alarm & Fault | 16VDC±0.3VDC for 12VDC | ||||
32VDC±0.6VDC for 24VDC | |||||
64VDC±1.2VDC for 48VDC | |||||
Transfer Time | 20ms(max) | ||||
System Parameter | Over-Load Protection | 110%the output,load>150%, beeps 0.5s every 1s, and Fault after 20s | |||
Output Short Circuit Protection | Current limit (Fault after 10s) | ||||
Surge Rating(10s) | 1:3(VA) | ||||
Power Saver | Load≤25W(Enabled on "P/S auto"Setting of Remote control) | ||||
Protections | Low battery, over charging, over load, over temp | ||||
General Specifications | Operating Temperature Range | 0ºC~40ºC | |||
Storage Temperature | -15ºC~60ºC | ||||
Operation humidity | 5% to 95%(non-condensing) | ||||
Audible Noise | 60dB max | ||||
cooling | Forced air,variable speed fan | ||||
Dimension(L*W*H) | 480*336*190mm | ||||
Net Weight(kg) | 19.5 | 21.5 | 23.5 | 28 |