Class II 275V 385V Imax 40ka LED Light Indication Circuit Breaker MCB Lightning Counter Surge Lightning Arresters Box

China Class II 275V 385V Imax 40ka LED Light Indication Circuit Breaker MCB Lightning Counter Surge Lightning Arresters Box, Find details about China Surge Lightning Protector, Lightning Protector from Class II 275V 385V Imax 40ka LED Light Indication Circuit Breaker MCB Lightning Counter Surge Lightning Arresters Box

Model NO.
BT 5L CM 275/40 3+1
Shape
Long Square
Material
Plastic
Certification
ROHS, ISO9001, Ce
Brand
Telebahn
Rated Voltage UC
275V
in 8/20us
20ka
Imax 8/20us
40ka
Trademark
Telebahn
Transport Package
in Cartons
Specification
55*32*27cm/carton size
Origin
China
HS Code
8536300000
Model NO.
BT 5L CM 275/40 3+1
Shape
Long Square
Material
Plastic
Certification
ROHS, ISO9001, Ce
Brand
Telebahn
Rated Voltage UC
275V
in 8/20us
20ka
Imax 8/20us
40ka
Trademark
Telebahn
Transport Package
in Cartons
Specification
55*32*27cm/carton size
Origin
China
HS Code
8536300000

Class II 275V 385V Imax 40ka LED Light Indication Circuit Breaker MCB Lightning Counter Surge Lightning Arresters Box

Class II 275V 385V Imax 40ka LED Light Indication Circuit Breaker MCB Lightning Counter Surge Lightning Arresters Box
Class II 275V 385V Imax 40ka LED Light Indication Circuit Breaker MCB Lightning Counter Surge Lightning Arresters Box

Product Description:
Adopting Class II SPD to combine "3+1" circuit, protecting low voltage equipment from surge damages, applied in TT system, designed according to IEC61643-1/GB 18802.1
Main character
:
1. Green light indicates normal and red light indicates fault for operation

2.  Built-in circuit breaker, and thermal disconnection device, when the fault occurred, the thermal disconnection device will cut off the SPD from the power net, the green window will change
3. Impulse counter function, recording the lightning events
4. External wiring terminal, easy for connection, suitable for indoor application

 

Technical data:

Type

BT 5L CM 275/40 3+1BT 5L CM 385/40 3+1
Norminal a.c voltage Un230V/400V230V/400V
Rated voltage (max.continuous a.c. voltage) (L-N) Uc275V385V
Rated voltage  (max. continuous a.c. voltage) (N-PE) Uc255V 255V
Nominal discharge current (8/20) In 20kA (L-N) 40KA (N-PE) 20kA (L-N) 40KA (N-PE) 
max. discharge current (8/20) [Imax] 40kA (L-N) 65KA (N-PE) 40kA (L-N) 65KA (N-PE) 
Voltage protection level at In [Up] ≤ 1.25kV (L-N)  ≤1.5KV (N-PE)≤ 1.25kV (L-N)  ≤1.5KV (N-PE)
Response time [tA] ≤ 25ns≤ 25ns
Operating temperature range [Tu]                                              -40°C...+80°C
Cross-sectional area                                 1.5mm2 ~ 25mm2 solid / flexible
Mounting on                                               4 x 4.5 screws
Enclosure material                                                  Metal
Test standards                             IEC 61643-11; EN 61643-11; GB 18802.11
Certification                                              CE (LVD, EMC)
Type of remote signalling contact                                             Switching contact
Switching capacity                    AC:250V/0.5A; DC:250V/0.1A;150V/0.2A;750V/0.5A
Cross-sectional area for remote signalling contact                                       Max. 1.5mm2 solid / flexible
Ordering information
Type BT 5L CM 275/40 3+1BT 5L CM 385/40 3+1
Art.-No. 840 884840 888
Packing unit 1pc(s)1pc(s)


Class II 275V 385V Imax 40ka LED Light Indication Circuit Breaker MCB Lightning Counter Surge Lightning Arresters Box
Class II 275V 385V Imax 40ka LED Light Indication Circuit Breaker MCB Lightning Counter Surge Lightning Arresters Box

Class II 275V 385V Imax 40ka LED Light Indication Circuit Breaker MCB Lightning Counter Surge Lightning Arresters Box
Class II 275V 385V Imax 40ka LED Light Indication Circuit Breaker MCB Lightning Counter Surge Lightning Arresters Box



Class II 275V 385V Imax 40ka LED Light Indication Circuit Breaker MCB Lightning Counter Surge Lightning Arresters Box