Water Cooled Screw Chiller Glycol Chiller for Pharmaceutical Reaction Kettle

China Water Cooled Screw Chiller Glycol Chiller for Pharmaceutical Reaction Kettle, Find details about China Chiller, Water Cooled Chiller from Water Cooled Screw Chiller Glycol Chiller for Pharmaceutical Reaction Kettle

Model NO.
ESGW series
Application Fields
Pharmaceutical
Application Machine
Reaction Kettle
Certification
CE
Condition
New
Compressor
Hanbell, Bitzer
Controller
Touch Screen Microcomputer Control
Evaporator
Shell and Tube
Condenser
Shell and Tube
Refrigerant
R22, R404A
Electrical Component
Schneider, FUJI
Starter
Wye-Delta Starter
Hot Water
Heat Recovery Optional
Expansion Valve
Danfoss, Emerson
Capacity Control
Multi Steps Control
Chiller Color
White
Sight Glass
Emerson
Service
OEM, ODM
Trademark
ESACIR
Transport Package
Wooden Case
Specification
Chilled liquid outlet temp.: -5, -10, -15C
Origin
Shenzhen
HS Code
8418692090
Model NO.
ESGW series
Application Fields
Pharmaceutical
Application Machine
Reaction Kettle
Certification
CE
Condition
New
Compressor
Hanbell, Bitzer
Controller
Touch Screen Microcomputer Control
Evaporator
Shell and Tube
Condenser
Shell and Tube
Refrigerant
R22, R404A
Electrical Component
Schneider, FUJI
Starter
Wye-Delta Starter
Hot Water
Heat Recovery Optional
Expansion Valve
Danfoss, Emerson
Capacity Control
Multi Steps Control
Chiller Color
White
Sight Glass
Emerson
Service
OEM, ODM
Trademark
ESACIR
Transport Package
Wooden Case
Specification
Chilled liquid outlet temp.: -5, -10, -15C
Origin
Shenzhen
HS Code
8418692090
Water Cooled Screw Chiller Glycol Chiller For Pharmaceutical Reaction Kettle

1. Eurostars water cooled screw glycol chiller main components

(1)Well Known Brand Compressor
*Chiller adopts Germany BITZER or Taiwan HANBELL brand semi-hermetic screw compressor. The latest 5 to 6 patented screw rotor profile with excellent efficiency for energy saving purpose
*Adjustable infinite or closely stepped capacity control, features energy efficient, stable and quiet running.
*Most advanced patented highest precision manufacturing process.
*Built-in full intelligent monitoring and protection including thermal motor temperature monitoring, phase sequence monitoring, manual reset lock-out, oil temperature sensor.
(2)Micro-programming Control System
*Microcomputer and Industrial PLC for options,combined with compressor capacity control system, precisely monitor.
*Integrated protection for low temperature, high/low pressure, anti-freezing, phase missing, anti-phase, overload, motor over temperature, oil differential, flow switch, start up latency.
*Optional operation language, menu leading, unit running state easy to adjust.
*Easy Installation, Reliable Running
(3)Design features
*Shell and tube evaporator and condenser, high efficient thread copper tube (material change on request).
*Siemens PLC control optional, LCD touch screen interface, easy operation, Standard design charged.
*R22, R134a for option.
*380V-415V-480V/50/60HZ, 3PH for standard design. Chiller unit can be supplied according to different requirements.
*High COP, with cooling tower using to cool the condenser by water instead of by air.
*Water cooled glycol chiller smart design, and small space, very small noise without fans.
*Good applied to hot ambient temperature country

Water Cooled Screw Chiller Glycol Chiller for Pharmaceutical Reaction Kettle

2. Water cooled screw glycol chiller main characteristics 
(1)The choice of famous of semi-hermetic screw compressor, high efficiency,quiet operation, simple operation and long life.
(2)Using the world famous brand refrigeration parts, to ensure the quality and stable unit.
(3)Shell and tube evaporator, condenser are high efficiency and ensure a good cooling unit performance.
(4)Independent of the cooling loop, separate maintenance and repair without affecting the machinery usage.
(5)The chiller adopts microcomputer control, energy control system with the compressor section can be timely and accurate cooling capacity control mechanism and the cooling load matching, to ensure the most efficient plant operation, lowest energy consumption and achieve energy-saving and reliable operation.
(6)Able to monitor the setting of actual temp, and display temp, trend in hours or daily.

3. Eurostars water cooled screw glycol chiller brief technical data 
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Low Temperature Water Cooled Screw Chiller (Heat Recovery)(-10ºC/R404A)
ESGW-031ISKOY041ISKOY055ISKOY067ISKOY075ISKOY089ISKOY101ISKOY108ISKOY121ISKOY141ISKOY162ISKOY175ISKOY
031ISKOVY041ISKOVY055ISKOVY067ISKOVY075ISKOVY089ISKOVY101ISKOVY108ISKOVY121ISKOVY141ISKOVY162ISKOVY175ISKOVY
Rated Cooling CapacityKW5978102136152176203224242287336358
USRT16.822.229.038.743.250.057.763.768.881.695.5101.8
X1000 Kcal/h50.767.187.7116.9130.7151.3174.5192.6208.1246.8288.9307.8
Low Temperature Water Cooled Screw Chiller (Heat Recovery)(-10ºC/R404A)
ESGW-183ISKOY208ISKOY230ISKOY234ISKOY278ISKOY297ISKOY392ISKOY443ISKOY062IDKOY134IDKOY150IDKOY202IDKOY
183ISKOVY208ISKOVY230ISKOVY234ISKOVY278ISKOVY297ISKOVY392ISKOVY443ISKOVY062IDKOVY134IDKOVY150IDKOVY202IDKOVY
Rated Cooling CapacityKW374435478513573717845943118272305407
USRT106.3123.7135.9145.9162.9203.9240.3268.133.677.386.7115.7
X1000 Kcal/h321.6374.0411.0441.1492.7616.5726.6810.8101.5233.9262.3350.0
Low Temperature Water Cooled Screw Chiller (Heat Recovery)(-10ºC/R404A)
ESGW-304IDKOY324IDKOY350IDKOY366IDKOY416IDKOY460IDKOY468IDKOY556IDKOY594IDKOY784IDKOY886IDKOY
304IDKOVY324IDKOVY350IDKOVY366IDKOVY416IDKOVY460IDKOVY468IDKOVY556IDKOVY594IDKOVY784IDKOVY886IDKOVY
Rated Cooling CapacityKW60767171574887095510261145143516891886
USRT172.6190.8203.3212.7247.4271.5291.7325.6408.0480.2536.3
X1000 Kcal/h521.9577.0614.8643.2748.1821.2882.2984.51233.91452.31621.7

Remarks:
(1) Rated Cooling Capacity Based on: cooling water in/outlet 30ºC/35ºC.
(2)Chilled glycol-water liquid in/outlet temp. -5ºC/-10ºC
(3)Chilled glycol-waterl iquid range: -10~0ºC; Cooling water range: 15ºC~40ºC.

4.Eurostars water cooled chiller series
Water Cooled Screw Chiller Glycol Chiller for Pharmaceutical Reaction Kettle
Water cooled screw chiller(with dual compressors,dual condenser)
Water cooled screw chiller(with single compressor, single condenser)
Water cooled screw chiller(with flooded evaporator)
Water cooled screw chiller with heat recovery
Water cooled heat pump chiller
Water cooled heat pump chiller with heat recovery
Water cooled flooded screw chiller with heat recovery
Water cooled flooded heat pump chiller
Water cooled centrifugal water chiller

5. Water cooled screw glycol chiller flow chart system
Water Cooled Screw Chiller Glycol Chiller for Pharmaceutical Reaction Kettle

 
6. FAQ about glycol for industrial chiller
Glycol is a very important element in any cooling system. Despite its ubiquity and its importance, most customers don't fully understand all that it does. In an effort to clear up some of the confusion about glycol, here are our answers to the most commonly asked questions.

Q: What is Glycol?
A: Glycol is a water-miscible organic compound in the alcohol family. It is commonly used for cooling in industrial and mechanical applications. Glycol is sometimes called antifreeze or a coolant. Though it acts similarly to a refrigerant, and someone may refer to glycol as a refrigerant, this statement is incorrect. Glycol cools solely through heat transfer in an exchanger; whereas, refrigerant uses an evaporation-condensation cycle to remove heat.

Q: What does glycol do in a processing cooling system?
A: The most important role glycol plays in a process cooling system is to adjust the temperature range of the system. Without any glycol in the system, the water will freeze at the normal 32°F (0°C). In this case, the system ambient temperature can never go below this temperature. However, many systems need temperature flexibility as pipes travel outside and into unheated areas. Adding glycol to the water lowers the freezing point. The percent of glycol determines what the new freezing point will be.

A lower freezing point means process fluid can be kept at colder temperatures. A greater difference between medium temperatures allows for a faster heat transfer process. Heat always travels in the direction of higher temperature to lower temperature. When a coolant with a colder temperature is used, more of the energy can be transferred from the other fluid or process to the coolant.

Q: What are the benefits of using glycol in my system?
A: Glycol often contains corrosion inhibitors which can help to prolong the life of components. Its main function is to enable a cooling system to operate at temperatures below the freezing point of water. Certain systems may require this lowered cooling for optimum performance.

7. Eurostars Company Ceritifcate & Customer Visiting
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.
Water Cooled Screw Chiller Glycol Chiller for Pharmaceutical Reaction Kettle

Water Cooled Screw Chiller Glycol Chiller for Pharmaceutical Reaction Kettle
Water Cooled Screw Chiller Glycol Chiller for Pharmaceutical Reaction Kettle

8. Our factory view

Modern new process and assemble line, including copper tube straighten machine, aluminum fin punching machine, three dimensional copper tube bending machine, tube expander machine, sheet metal laser cutting machine, numerical control punching machine, CNC bending machine, chiller, fan coil unit and AHU assemble line,. etc..
Water Cooled Screw Chiller Glycol Chiller for Pharmaceutical Reaction Kettle
Water Cooled Screw Chiller Glycol Chiller for Pharmaceutical Reaction Kettle


9. Eurostars water cooled chiller package and delivery
(1)Multiple packing: proved by tests of the compression resistance, throwing. And highly secured.
(2)Plywood case packing: High resistance of burst strength, ring crushing strength and tearing strength.
(3)Wooden frame parking: Damp-proved and high resistance burst strength and ring crush strength.
Water Cooled Screw Chiller Glycol Chiller for Pharmaceutical Reaction Kettle

10. Eurostars water cooled chiller projects

We exported chillers to Ukraine, New Zealand, Guatelmala, Peru, Chile, Norway, Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Sri Lanka, India, Saudi Arabia, Iran, Mexico, Argentina, etc..
Water Cooled Screw Chiller Glycol Chiller for Pharmaceutical Reaction Kettle
Water Cooled Screw Chiller Glycol Chiller for Pharmaceutical Reaction Kettle