IVY UC3 Approved 100A Electronic Motor Protective Relay Power Relay

China IVY UC3 Approved 100A Electronic Motor Protective Relay Power Relay, Find details about China Relays, Latching Relay from IVY UC3 Approved 100A Electronic Motor Protective Relay Power Relay

Model NO.
IM-M1202
Protective Characteristics
Sealed Relay
Action Principle
Electromagnetic Type
Size
Miniature
Type
Electric Parameter Relay
Product Name
100A Electronic Motor Protective Relay
Contact Material
Agsno2
Rated Load
100A, 250VAC
Coil Voltage
12VDC
Color
Black
Trademark
IVY
Transport Package
Cartons/Pallet
Specification
29*23.5*16mm
Origin
Zhejiang, China
HS Code
8536411000
Model NO.
IM-M1202
Protective Characteristics
Sealed Relay
Action Principle
Electromagnetic Type
Size
Miniature
Type
Electric Parameter Relay
Product Name
100A Electronic Motor Protective Relay
Contact Material
Agsno2
Rated Load
100A, 250VAC
Coil Voltage
12VDC
Color
Black
Trademark
IVY
Transport Package
Cartons/Pallet
Specification
29*23.5*16mm
Origin
Zhejiang, China
HS Code
8536411000
IVY UC3 Approved 100A Electronic Motor Protective Relay Power RelayIVY UC3 Approved 100A Electronic Motor Protective Relay Power RelayIVY UC3 Approved 100A Electronic Motor Protective Relay Power Relay
Basic DataDimensions(mm)29×23.5×16
Weight ( g )≈40g
Contact Arrangement1A/1B
Contact MaterialAgSnO2
Ambient Temperature-40~+75ºC
Vibration10~50Hz,1.5mm
Shock1000m/s²,(100g)
Specifications DataPower Consumption<3W
Operating Voltage10.5-16V
Max. Switching Current100A
Surge Current6000A/10ms
Motor Resistance32(1±15%
Contact Voltage<60mV
Contact Resistance≤1.0
Dielectric StrengthMotor to Contact>4000VAC,50/60Hz 1min
Across Open Contact>2000VAC,50/60Hz 1min
Electrical Life(120 cycles/H)10,000
(resistance 5 k + perceptual 5 k, co ϕ = 0.5)
Mechanical Life(3600 cycles/H)100,000
Pulse Time60ms(Advise 60ms~100ms)
Picking-up Time≤60ms
Release Time≤60ms
Insulation Resistance>1000MΩ(500VDC)
IVY UC3 Approved 100A Electronic Motor Protective Relay Power Relay
IVY UC3 Approved 100A Electronic Motor Protective Relay Power RelayIVY UC3 Approved 100A Electronic Motor Protective Relay Power RelayIVY UC3 Approved 100A Electronic Motor Protective Relay Power RelayIVY UC3 Approved 100A Electronic Motor Protective Relay Power RelayIVY UC3 Approved 100A Electronic Motor Protective Relay Power Relay           Cautions of Latching Relay:

             1.Suggestions of relay's input
            (1)Polarity-Please check the polarity inside of our technical specification, if single coil then"+ -" or "- +"are fine,
            you can change it by one pulse.If double coil then it's necessary to confirm "-+-" or "+-+"before leaving the our factory.
            (2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5
            times or 2 times of value or lower driving condition plz confirm with our engineer.
            (3)Relays'contact status may be changed during transportation or installation due to impact of external force,
            therefore please reset to the required status.
 
            2.Suggestions of relay's output
            (1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
            the installation.
            (2)When the relay will be connected with screw or bolts to the relays' terminals, plz make sure your connection is
            fastened and prevent relay from damages or other safety problems due to temp. Rise..
            (3)The sampling signal wires of products are limited, please do not pull or torque during installation.