China Chziri Braking Unit Regenerative Braking Unit 4030 for VFD Inverter, Find details about China Braking Unit, Regenerative Braking Unit from Chziri Braking Unit Regenerative Braking Unit 4030 for VFD Inverter
BREAKING RESISTOR(PWR) | ||||
220V | 0.75KW/220V | 80W/200Ω | 1 | |
1.5KW/220V | 200W/750Ω | 1 | ||
2.2KW/220V | 300W/70Ω | 1 | ||
380V | 0.75KW/380V | 80W/750Ω | 1 | |
1.5KW/380V | 200W/400Ω | 1 | ||
2.2KW/380V | 300W/250Ω | 1 | ||
3.7KW&4.0KW/380V | 400W/150Ω | 1 | ||
5.5KW/380V | 600W/100Ω | 1 | ||
7.5KW/380V | 800W/75Ω | 1 | ||
11KW/380V | 1000W/50Ω | 1 | ||
15KW/380V | 1500W/40Ω | 1 | ||
18.5KW/380V | 2500W/35Ω | 1 | ||
22KW/380V | 3000W/27.2Ω | 1500W13.6Ω*2PCS | 1set | |
30KW/380V | 5000W/19.2Ω | 2500W38.4Ω*2PCS | 1set | |
37KW/380V | 6000W/16Ω | 2000W 48Ω*3PCS | 1set | |
45KW/380V | 9600W/13.6Ω | 2500W 54.4Ω*4PCS | 1set | |
55KW/380V | 12000W/10Ω | 2000W 60Ω*6PCS | 1set | |
75KW/380V | 19200W/6.8Ω | 2500W 54.4Ω*8PCS | 1set | |
Braking Resistor Box | ||||
90KW | 9600W20R*3PCS | 1set | ||
110KW | 9600W20R*3PCS | 1set | ||
132KW-160KW | Power resistor unit | 40KW3.4R*1PCS | 1set | |
185KW-220KW | Power resistor unit | 60KW3.2R*1PCS | 1set | |
250-315KW | Power resistor unit | 40KW4.5R*2PCS | 1set | |
350-600KW | 60KW3R*3PCS | 1set |
braking unit type | AC200V~AC300V | AC380V~AC460V | |||||||
2015 | 2022 | 2030 | 4030 | 4045 | 4220 | 4300 | |||
in-out speciality | peak current(A) | 50 | 75 | 90 | 50 | 75 | 300 | 500 | |
rate current(A) | 15 | 25 | 30 | 15 | 25 | 85 | 120 | ||
wiring mm 2 | 4-6 | 4-6 | 6-8 | 4-6 | 4-6 | 16-36 | 25-50 | ||
brake start voltage(V) | 380V± 5V | DC630/DC660/DC690/DC730/DC760V± 10V | |||||||
Max hysteresis error | About 8V | About 16V | |||||||
Synchronization signal | can be more than one machine, recommended not to exceed three | ||||||||
power | DC busbar voltage | DC 243-400V | DC 460~800V | ||||||
safequard | Radiator Overheated | temperature on-off+85C | |||||||
Fault Output | RELAY Contact 0.6A125VAC/2A30VDC(Ta, Tb, Tc) | ||||||||
External power supply | R, S terminal | it' s need to connect 380V/AC with the R/S terminal for the 4220 and 4300, when external power available, red light(POWER) on | |||||||
working condition of heat elimination fan machine | braking unit, the fan start work when temperature rise of energy absorption resistor board more than +45C, stop when below +45C. | ||||||||
deictic function | power light | when DC bus terminal get voltage input more than 50V, the red light(POWER) on | |||||||
running light | when braking unit working, green light(BRAKINK) on | ||||||||
environmental condition | ambient temperature | Without frozen when -10C ~+40C | |||||||
strorage temperature | -10C~+50C | ||||||||
humidity | No coagulate frost when 90%RH | ||||||||
vibrate | 1G when 10~20Hz, 0.2G when 20~50Hz | ||||||||
Machinery structure | wall-hooked IP20 |