China 1: 8 Cassette Type Fiber Optic PLC Splitter, Find details about China PLC Splitter, PLC from 1: 8 Cassette Type Fiber Optic PLC Splitter
Planar Light wave Circuits (PLC) splitters are manufactured using silica glass waveguide circuits and extremely
precise alignment of optic fibers in very small package. They split or combine light from one or two incoming
fibers to multiple numbers of outgoing fibers.
They perform uniformly over a wide spectral range, with ultra-low losses. splitters are highly compact, reliable
and available in very wide range of fiber and connector types. All PLC splitters are fully compliant with the
Telcordia GR-1209 & GR-1221 standard.
Splitters contain no electronics and use no power. They are the network elements that put the passive in
Passive Optical Network and are available in a variety of split ratios, including1:2, 1:8, 1:16, 1:32,1:64,2:8,
2:16, 2:32 & 2:64.
Standard Compliance
. Telcordia GR-1221-CORE-1999 & GR-1209-CORE-2001
. TIA/EIA-568B.3 Fiber Optic Cabling Components Standard
. IEE802.3z Standards for Fiber Optic Cabling
. RoHS Certified for European Market Requirements
Features & Benefits
. Low insertion losses, High Uniformity, High Reliability, High directivity.
. Ultra-broadband performance (1250-1650nm)
. Low Polarization Dependant Loses (PDL) and Polarization Mode Dispersion (PMD)
. 1 or 2 input channels and up to 64 output channels
. Ultra small, easy installation, suitable for all applications
. Available with all type of packages and connectors
. Ready for use in uncontrolled environment
Telcordia 1209 & 1221 Test results:
Name of the test | Condition | Duration |
Temperature- Humidity aging | 85°C and 85% RH | 7 days |
Vibration | 10 - 55Hz, 1.52mm double amplitude, in three axes | 1 hour |
Component Impact Test | Impact of 500g (mass<=0.125kg), 1ms , half sine pulse | 2 impacts |
Temperature Cycling Test | -40°C to + 70°C , Ramp rate: 1°C /min, Dwell time >15min | 10 cycles |
Temperature- Humidity cycling | -40°C to + 85°C , between 10°C and 23°C - 85% RH, at 85°C -20%RH, between 23°C and 85°C - maintain a linear change in RH, below 10°C - uncontrolled RH | 14 days |
Water Immersion | 43 ± 2°C , PH 5.5 ± 0.5 | 7 days |
Fiber Side Pull test | 0.23 kg load, 90° angle , 2 directions | 5 seconds |
Fiber Side Pull test | 0.45 Kg load for Single Input Fiber , 1.5 Kg load for 8 Fiber Ribbon Outputs | 5 seconds |
Specifications
1 x N | ||||||||
Parameter | Unit | 1 x 2 | 1 x 4 | 1 x 8 | 1 x 16 | 1 x 32 | 1 x 64 | |
Insertion Loss | Max. | dB | 3.8 | 7.0 | 10.4 | 13.9 | 17.2 | 22.0 |
Channel Uniformity | Max. | dB | 0.6 | 0.5 | 0.5 | 1.4 | 1.6 | 2.5 |
Polarization Dependent Loss | Max. | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
Wavelength Dependent Loss | Max. | dB | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
Temperature Dependent Loss | Max. | dB | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Connector Dependent Loss | Max. | dB | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
Operating Wavelength | Min.-Max | nm | 1250 ~ 1650 | |||||
Return Loss | Min. | dB | 55 | |||||
Directivity | Min. | dB | 55 | |||||
Operating Temperature | °C | -40 ~ + 85 | ||||||
Storage Temperature | °C | -40 ~ + 85 | ||||||
Maximum Input Power | Max. | mW | 500 | |||||
Fiber Type | - | ITU G.652D or G.657A |
2 x N | ||||||||
Parameter | Unit | 2 x 2 | 2 x 4 | 2 x 8 | 2 x 16 | 2 x 32 | 2 x 64 | |
Insertion Loss | Max. | dB | 4.0 | 7.3 | 10.7 | 14 | 17.5 | 22.5 |
Channel Uniformity | Max. | dB | 0.8 | 1.0 | 1.0 | 1.5 | 1.8 | 3.0 |
Polarization Dependent Loss | Max. | dB | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.4 |
Wavelength Dependent Loss | Max. | dB | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
Temperature Dependent Loss | Max. | dB | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Connector Dependent Loss | Max. | dB | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
Operating Wavelength | Min.-Max. | nm | 1250 ~ 1650 | |||||
Return Loss | Min. | dB | 55 | |||||
Directivity | Min. | dB | 55 | |||||
Operating Temperature | °C | -40 ~ + 85 | ||||||
Storage Temperature | °C | -40 ~ + 85 | ||||||
Maximum Input Power | Max. | mW | 500 | |||||
Fiber Type | - | ITU G.652D or G.657A |
Ordering Guide
A | Input Port | 1=1 Port, 2=2 Ports |
B | Output Port | 02=2 Ports, 16=16 Ports, 64=64 Ports |
C | Packaging Type | T=Steel Tube Type, B=Boxed Type, M=Micro Type |
D | Diameter of Input Fiber | 09=0.9mm, 20=2.0mm, 30=3.0mm |
E | Input Fiber Connector type | FP, SP, SA, LP (As noted in Connector type code chart ) |
F | Input Fiber Length | 10=1M, 15=1.5M, 20=2M |
G | Diameter of Output Fiber | 09=0.9mm, 20=2.0mm, 30=3.0mm |
H | Output Fiber Connector type | FP, SP, SA, LP (As noted in Connector type code chart ) |
I | Output Fiber Length | 05=0.5M, 10=1M, 15=1.5M, 20=2M |
Connector Type Code
Code | Connector | Code | Connector | Code | Connector | Code | Connector | Code | Connector | Code | Connector |
FP | FC/PC | FA | FC/APC | LP | LC/PC | LA | LC/APC | MU | MU | DN | DIN |
SP | SC/PC | SA | SC/APC | TP | ST/PC | TA | ST/APC | MT | MTRJ | E2 | E2000 |
Ordering Sample
Part Number | Description |
PLC-108B-30SP05-30SP05 | 1*8 PLC splitter, boxed type package, input and output fiber Ф 3, length 0.5M, and connector SC/PC. |
PLC-232M-09SP10-09SP10 | 2*32 PLC splitter, micro type package, input and output fiber Ф 0.9, length 1M, and connector SC/PC. |