UV Water Filtration (80W) Systems for Underground Water

China UV Water Filtration (80W) Systems for Underground Water, Find details about China UV Sterilizer, Ultraviolet Lamp from UV Water Filtration (80W) Systems for Underground Water

Model NO.
YLC-150
Inlet and Outlet
Dn32mm
Lifespan of UV Lamp
9000-12000 Hours
Interface Type
Flange
Flow Rate
6m3/H
Chamber Size
930*108*240mm
Working Pressure
0.6 MPa
Raw Water
Drinking Water/Waste Water/Underground Water
Brand of Ballast
Domestic Brand
Trademark
YLD
Transport Package
Plywood Case Into Container
Specification
CE, SGS, ISO
Origin
Jiangyin, Jiangsu
HS Code
8421219990
Model NO.
YLC-150
Inlet and Outlet
Dn32mm
Lifespan of UV Lamp
9000-12000 Hours
Interface Type
Flange
Flow Rate
6m3/H
Chamber Size
930*108*240mm
Working Pressure
0.6 MPa
Raw Water
Drinking Water/Waste Water/Underground Water
Brand of Ballast
Domestic Brand
Trademark
YLD
Transport Package
Plywood Case Into Container
Specification
CE, SGS, ISO
Origin
Jiangyin, Jiangsu
HS Code
8421219990
UV Water Filtration(80W) Systems For Underground Water
 

Frequently Asked Questions About Ultraviolet (UV) Purification
1. What is UV? 
Ultraviolet (UV) light is at the invisible, violet end of the light spectrum. Even though 
 
we can't see UV light, we are exposed to UV rays from all light sources, including the sun.
 
2. How does ultraviolet light purify water? 
UV-C rays penetrate the cells of harmful bacteria and viruses in our drinking water, 
 
destroying their ability to reproduce. Without this ability, these organisms die and no 
 
longer pose a health threat. It is a simple but very effective process, with the system 
 
destroying 99.99% of harmful microorganisms.
 
3. Why not use chlorine instead? 
Chlorine changes the taste and odor of water. Chlorinating also produces harmful by-
 
products called Trihalomethanes (THMs) which are linked to incidence of cancer.
 
4. Does a UV system use a lot of energy? 
No, the UV unit will use about the same amount of energy as a 60 watt light bulb. It is a 
 
cost effective, natural way to increase water quality.
 
5. Why do UV purifiers require sediment pre-filtration? 
UV systems require pre-filtration to maintain effectiveness as sediment and other 
 
contaminants in the water can create a "shadow" which prevents the UV rays from reaching 
 
and disinfecting the harmful microorganisms.
 
6. How often does the UV light bulb (lamp) need to be replaced? 
It is essential that you change your UV lamp annually. The ability of the lamp to emit UV 
 
light decreases over one year in operation. Remember - UV light is invisible! Even though 
 
the lamp is still glowing after one year, there might not be enough UV light reaching your 
 
water to be effective.
 
7. How often do your need to replace the sleeve? 
The sleeve doesn't need to be replaced unless it is broken, but it will need to be cleaned 
 
several times a year in order to keep the bulb effective in delivering high water quality.

AAA:

01.What is the source of raw water to be treated?
--is it underground water or well water?or river water ,other source?
02.What is the capacity(m3/hour) you required for this sterilizer?
--most IMPORTANT requirement.
03.What will the treated water be used for?
--for human drinking or industry purpose?
04. What is the power supply in your country?
--220V 50Hz?

Application:

Drinking water treatment
RO Plants
Mineral water plants
Sewage water recycling
Effluent recycling
Municipal water supply
Zero liquid discharge systems


Technical parameters:

model

capacity

Power

inlet-outlet

reactor

panel

Anchor

G weight

 

m³/hour

watt

mm

L×W×H

cm

screw

Kg

YLCn-005

0.3

16

1/2″

30×6×11

without

without

5

YLCn-008

1

25

1/2″

47×6.3×11

without

without

10

YLCn-050

2

40

1″

100×9×20

Φ8.9×25
(d×L)

69×4×Φ1

25

YLCn-150

6

80

1+1/4″

100×11×23

 

69×4×Φ1

30

YLCn-200

8

120

1+1/2″

100×15.9×30

Φ8.9×45
(d×L)

69×7×Φ1

35

YLCn-300

12

160

2″

100×15.9×32

 

69×7×Φ1

40

YLC-050

2

40

DN25/1″

100×8.9×30

25×30×12
(W×H×D)

60×4×Φ1

45

YLC-150

6

80

DN32/11/4″

100×10.8×30

 

60×4×Φ1

50

YLC-200

8

120

DN40/11/2″

100×15.9×40

 

60×7×Φ1

60

YLC-300

12

160

DN50/2″

100×15.9×40

 

60×7×Φ1

70

YLC-360

15

200

DN65/21/2″

100×15.9×40

 

60×7×Φ1

120

YLC-500

20

240

DN65/21/2″

100×21.9×50

 

60×11×Φ1.2

130

YLC-600

25

280

DN80/3″

100×21.9×50

 

60×11×Φ1.2

140

YLC-700

30

320

DN100/4″

100×21.9×50

 

60×11×Φ1.2

150

YLC-1000

40

360

DN100/4″

100×21.9×50

 

60×11×Φ1.2

160

YLC-1200

50

400

DN125/5″

100×21.9×50

 

60×11×Φ1.2

180

YLC-1500

60

420

DN150/6″

170×27.3×57

 

120×16×Φ1.4

210

YLC-2000

80

560

DN150/6″

170×27.3×57

 

120×16×Φ1.4

220

YLC-2500

100

700

DN150/6″

170×27.3×57

60×128×30
(W×H×D)

120×16×Φ1.4

275

YLC-3000

125

840

DN150/6″

170×27.3×57

 

120×16×Φ1.4

300

YLC-4000

150

1120

DN200/8″

173×32.5×65

 

120×20×Φ1.6

325

YLC-5000

200

1400

DN200/8″

173×37.7×72

 

120×22×Φ1.6

350

YLC-7000

300

2100

DN250/10″

175×42.6×80

 

120×24×Φ2.0

400

YLC-10K

400

2520

DN250/10″

176×52.9×95

60×150×40
(W×H×D)

120×22×Φ2.2

475

YLC-15K

600

3080

DN300/12″

176×78×110

 

120×32×Φ2.4

600

YLC-20K

800

3920

DN350/14″

Designated

Designated

Designated

Designated

YLC-25K

1000

4760

DN350/14″

Designated

Designated

Designated

Designated