China Double Conversion Online UPS with USB Port and Parallel Redundancy Function for Intelligent Battery Management System, Find details about China Uninterruptible Power Supply, Online UPS from Double Conversion Online UPS with USB Port and Parallel Redundancy Function for Intelligent Battery Management System
Double Conversion Online UPS with USB Port and Parallel Redundancy Function for Intelligent Battery Management System
Quick View
1: China UPS with good quality and low price, same quality like APC, Eaton, MGE UPS.
2: 3 Phase UPS with 50Hz / 60Hz Frequency and 380V / 400V / 415VAC Input and output
3: Triphase UPS with Emergency power off function (EPO)
3: UPS with SNMP , USB , RS232 Ports
4: UPS with Parallel Redundancy Function
UPS Key Features
Model | 33Q10KL | 33Q 20KL | 33Q 30KL | 33Q 40KL | 33Q 60KL | 33Q 80KL | Comments |
Input | |||||||
Input voltage | |||||||
Rated voltage | 380VAC/220VAC | 380VAC | |||||
Phase | three phase with ground | ||||||
Turn on voltage range | (120±5~274±5)VAC | (207±9~475±9)VAC | |||||
Bypass voltage range | (60±5~300±5)VAC | (105±9~518±9)VAC | Could be adjusted by software. | ||||
Bypass low loss | 60VAC~220VAC(default 60VAC) | 105VAC~380VAC (default 105VAC) | |||||
Bypass low comeback | Low loss +5VAC | Low loss +17VAC | |||||
Bypass high loss | 220VAC~300VAC(default 300VAC) | 380VAC~475VAC (default 475VAC) | |||||
Bypass high comeback | High loss -5VAC | High loss -17VAC | |||||
Line low loss /comeback | (120±5) VAC /(140±5) VAC | (207±9) VAC /(242±9)VAC | load≤50% | ||||
(140±5) VAC /(160±5) VAC | (242±9) VAC /(276±9)VAC | 50%<load ≤90% | |||||
(160±5) VAC /(175±5) VAC | (276±9) VAC /(302±9)VAC | load>90% | |||||
Line high loss/comeback | (275±5)VAC/(260±5)VAC | (475±9)VAC/(449±9)VAC | |||||
Input frequency | |||||||
Rated frequency | 50Hz | ||||||
Frequency low loss | (40~49) ±0.2Hz(default:46Hz) | Could be adjusted by software. | |||||
Frequency low comeback | Frequency low loss +0.5Hz | ||||||
Frequency high loss | (51~60)±0.2Hz(default:54Hz) | ||||||
Frequency high comeback | Frequency high loss -0.5Hz | ||||||
Input power factor | |||||||
Input power factor | > 0.99 | 33Q 10-40KL:220VAC,full R load 33Q 60-80KL: 380VAC,full R load | |||||
Generator | Support generator input | Generator rating≥2*UPS rating | |||||
Input current | |||||||
Rated current | 14A | 28A | 42A | 67A | 80A | 105A | |
Input THDI | <= 10% | ||||||
Output protection | |||||||
Rating protection | 32A Breaker | 50A Breaker | 60A Breaker | 80A Breaker | 100A Breaker | 125A Breaker | |
Output power | |||||||
VA/watt | 10KVA/8KW | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | 60KVA/ 48KW | 80KVA/ 64KW | |
Rated voltage | 220VAC | 380VAC | Sine wave | ||||
Voltage range | 200/208/220/230/240VAC | 345/359/380/397/415 VAC | 33Q 10-40KL: Could be adjusted by software. 10% derating for 208VAC/200VAC. 33Q 60-80KL: Could be adjusted by software. 10% derating for 345VAC/359VAC. | ||||
Voltage regulation | ±1% | ||||||
Voltage distortion | ≤5% | ≤10% | Full RCD load | ||||
≤3% | Full R load | ||||||
DC offset | ≤200mV | ||||||
Transient response | ≤9% | R load 0%~100%~0% | |||||
≤6% | R load 20%~100%~20% | ||||||
Transient recovery | ≤60ms voltage recovery to 90% | Full RCD load | |||||
Bypass output before turn-on | YES | ||||||
Crest ration | 3:1 | ||||||
Output frequency range | |||||||
Normal mode | 1,Same as input frequency(46Hz~54Hz) 2,50Hz(Input frequency>54Hz or Input frequency<46Hz) | ||||||
Battery mode | (50±0.1) Hz | ||||||
Slew rate | 1 Hz/Sec | ||||||
Efficiency | |||||||
Normal mode | > 93% | > 90% | |||||
Battery mode | > 90% | > 90% | |||||
Overload | |||||||
Normal mode /battery mode | Overload warning only | 105%±5%≤load | |||||
1min,then transfer to bypass and alarm. | 105%±5% | ||||||
30S,then transfer to bypass and alarm. | 125%±5% | ||||||
300mS, then transfer to bypass and alarm. | load>150%±5% | ||||||
Automatically retransfer | YES | ||||||
Short protection | |||||||
Normal/ battery mode | YES | ||||||
Transfer time | |||||||
Normal to battery mode | 0mS | ||||||
Battery to normal mode | 0mS | ||||||
Normal to bypass mode | <4mS | 0mS | |||||
Bypass to normal mode | <4mS | 0mS | |||||
Battery and charger | |||||||
Battery | |||||||
Rated voltage | 192VDC | 240VDC | 192VDC*2 | 192VDC*2 | 480VDC | ||
Type/Rating | |||||||
Battery quantity | 16 | 20 | 16*2 | 16*2 | 40 | ||
Backup time | |||||||
Protection | |||||||
Low alarm voltage /comebackvoltage | (180.8V±4V)/ (188.8V±4V) | (226V±4V)/ (236V±4V) | (180.8V±4V)/ (188.8V±4V) | (226V±4V)/ (236V±4V) | (452V±4V)/ (472V±4V) | 33Q 30KL use two | |
Shutdown voltage/ comeback voltage | 160V±4V/168V±4V | (200V±4V)/ (210V±4V) | 160V±4V/ 168V±4V | (200V±4V)/ (210V±4V) | (400V±4V)/ (420V±4V) | ||
DC protection | |||||||
Overcharge protection/ comeback voltage | (249.6V±4V)/ (216V±4V) | (312V±4V) (270V±4V) | (249.6V±4V)/ (216V±4V) | (312V±4V) (270V±4V) | (624V±4V) (540V±4V) | ||
Leakage current | < 500uA | ||||||
Over discharge protection | 14.5h | Could be set by software | |||||
Battery test | |||||||
Battery weak | YES | ||||||
Battery fault | YES | ||||||
Charger | |||||||
Output voltage | (219.2±3)VDC | (277±3)VDC | (219.2±3)VDC | (277±3)VDC | (554±3)VDC | ||
Charge time | Depends on the external battery capacity | ||||||
Charge current | 7.5A | 6A | 5A | 4A | 10A | ||
Interface | |||||||
Alarm silence | YES | ||||||
DC power turn-on | YES | ||||||
Automatically retransfer | YES | ||||||
Audio alarm | |||||||
Battery mode | Beep/4s | ||||||
Battery low/ charger fault | Beep/1s | ||||||
UPS fault | Continue beep | ||||||
Overload | Beep/1s | ||||||
Bypass mode | Beep/2Min | ||||||
L/N inverse | Beep/2Min | ||||||
Communication | |||||||
RS232 interface | YES | ||||||
Intelligent slot | YES | ||||||
Monitor software | Appending with UPS | ||||||
Cooling | |||||||
Force air cooling | |||||||
Display | |||||||
LCD/LED displays UPS status | |||||||
Environment | |||||||
Work temperature | 0ºC~40ºC | ||||||
Altitude | <1000m | ||||||
Audible noise | ≤60dB | ||||||
Storage temperature | -15ºC~45ºC | ||||||
Work humidity | 20%~95% | ||||||
Standard | |||||||
EMS | |||||||
ESD | IEC61000-4-2 | Level4 | |||||
RS | IEC61000-4-3 | Level3 | |||||
EFT | IEC61000-4-4 | Level4 | |||||
Surge | IEC61000-4-5 | Level4 | |||||
EMI | |||||||
Conducted | EN55022 | Class A | |||||
Radiated | EN55022 | Class A | |||||
Safety | |||||||
Safety | GB4943-2001/IEC62040-1 | ||||||
Machinery features | |||||||
Size | |||||||
Outline dimension and net weight | |||||||
L*W*H (mm) | 710*260*717 | 840*515*1135 | |||||
Net weight(Kg) | 45/93 | 50/98 | 195 | 208 | |||
Optional functions | |||||||
60Hz | Optional | Set by software | |||||
Converter mode | Optional | Set by software | |||||
ECO | Optional | Optional | Available and set by software | ||||
EPO | Optional | Optional | |||||
*Specification is subject to change without further notice |