Cotrust Cth200 Basic PLC H224 14di /10do Relay Output Ethernet Port

China Cotrust Cth200 Basic PLC H224 14di/10do Relay Output Ethernet Port, Find details about China PLC, Ethernet Port from Cotrust Cth200 Basic PLC H224 14di/10do Relay Output Ethernet Port

Model NO.
CTH2 214-1BA33-0X24
Customized
Customized
Weight
0.45kg
Trademark
COTRUST
Transport Package
CTN
Specification
137*80*62mm
Origin
China
HS Code
853710119
Model NO.
CTH2 214-1BA33-0X24
Customized
Customized
Weight
0.45kg
Trademark
COTRUST
Transport Package
CTN
Specification
137*80*62mm
Origin
China
HS Code
853710119

Order Data

Specification

Order No.

CPU H224 basic:12KB program memory/8KB data memory,220VAC power supply,14DI*10DO relay  output,2A,1*PPI,1*FPORT,1*Ethernet port,expansion module and expansion board are not supported.

CTH2 214-1BA33-0X24


Performance Parameters

Physical Features 
Dimension(W×H×D)137×80×62mm
Power dissipation7W
Memory Features
Program memory8KB+4KB
Data memory8KB
General Features 
Timers total
      1ms
      10ms
      100ms
256
4
16
236
Counters total256
Internal memory bits256
Stored permanently on power downData permanent stored
Sequential control relay (S)256
Time Interrupts2 with 1ms resolution 
Edge Interrupts4 rising edges and/ or 4 falling edges 
Analog adjustmentNon
Boolean execution speed0.22µs
Float execution speed12µs
Clock embedded ,precision ±120s/m
BD expansion board interface number1
System indicator3,STOP,RUN,SF
RUN/STOP dial code Yes,2
Programming cardSupport
Memory cardNon Support
Rated input voltage24VDC
Power supply
Native and extended bus+5V
+24V
 
660mA
200mA
Integrated Communication Function
Communication Interface 2 communication ports ,PORT0:PPI/Free port,RS485;FPORT0:PPI/Free port,RS485
 
PPI baud rates(baud)9.6k,19.2k and 187.5k
Freeport baud rates(baud)1.2k ~ 115.2k
Maximum cable length
    Isolated repeater applied
    Isolated repeater unapplied
When it is 1000 m, baud rate is 187.5k; when it is 1200 m, 38.4k.
50m
Maximum number of stations 32 stations per segment,126 stations per network 
Maximum number of masters32
Physical interface2 RS485 port
IsolationNon
Ethernet Function
Communication port1 Ethernet port
Communication standardIEEE802.3 standard
Communication speed10Mbps and 100Mbps self-adaption
Adaptive cross connectionNon support
Interface to industrial Ethernet(10/100Mbps)RJ45 port
Protocol typeUDP/TCP protocol
Support MICO Ethernet programming, support Ethernet communication between PLC.
Collocation methodSupport the upper computer through the Ethernet port search PLC,
 support the mouth download system configuration.
Max Connections Each PLC supports up to 8 UDP connections and up to
4 TCP connections.
The maximum number of IT connections8 UDP_PPI connections, with 4 master stations and 
4 slave stations.
4 ModBus_TCP connections, 2 master stations and 
2 slave stations.
User data numberUp to 200 bytes are used for TCP/IP transmission.
Up to 240 bytes are used for ModBus_TCP transport.
Portlocal:1~65535
remote server:8888
Boot time or restart time after reset3 seconds
Indicator lampGreen RMC indicator: on: remote control in effect, 
off: remote control out

Green Ethernet indicator: on: connection, flicker: transmission; 
out: not connected
Maximum cable length100m
IsolationCommunication port isolation
I/O Features
Number of integrated digital inputs14
Input typeSink/Source
Number of integrated digital outputs10
Output typeRelay dry connect
Digital I/O mapping domain128DI/1280DQ
Analog I/O mapping domain32AI/32AQ
Maximum number of expandable I/O module7
Maximum digital I/O configurationIO:256(128DI/128DO)
Maximum analog I/O configuration64(32AI/32AQ)
Pulse catch inputs14
High-speed counters
    Total 
     Uniphase counters 
     Bi-phase counters 
 
4
4×50KHz
1×30KHz
Digital Input Features
Number of integrated digital input14
Input typeSink/ Source
Rated voltage24V DC
Input voltage range20.4-28.8V DC
Surge voltage35V DC,continuously 0.5s
Logical 1 Signal (minimum)
Logical  0 Signal (Maximum)
15 VDC,2.5mA
5 VDC,1mA
Allowable leakage current1mA
Input filter3.4ms and 6.4ms
Isolation(field side to logical circuit)500V AC,1min
Simultaneous input14
Maximum cable length
Shielded
Unshielded
500 M(standard input)
50 M(high-speed counters input)
300 M(standard input)
Digital Output Features 
Number of integrated digital output10
Output typeRelay dry connect
Rated voltage 24VDC or 110V/220VAC
Output voltage range5~30VDC:5~250VAC
Logical 1 Signal (minimum)-
Logical  0 Signal (Maximum) -
Rated current per point2A
Rated current for each common point8A
Leakage current (maximum)-
Surge current(Maximum) 7A
Lamp load (maximum)30W DC/200W AC
On resistance (contact)0.2Ω
Isolation(field side to logical circuit)
 
-
DelayOff to on:-
on to off:-
Contact life at rated load100000 times on and off
Simultaneous inputAll output point
Parallel outputNon
Maximum cable length
Shielded
Unshielded
500m
150m



RS485 communication port definition

Connector

PIN

PORT0(RS485)

FPORT0(RS485)

 Cotrust Cth200 Basic PLC H224 14di/10do Relay Output Ethernet Port

1

    Shell Grounded

 Shell Grounded

2

logically

logically

3

RS485+signal B

RS485+signal B

4

Send the application RTS

Send the application RTS

5

 logically

 logically

6

+5V, series connection 100 Ω resistance

+5V, series connection 100 Ω resistance

7

+24V

+24V

8

RS485-signal A

RS485-signal A

9

NC

NC

shell 

 Shell Grounded

 Shell Grounded