China Cotrust PLC 224e 14di/10do Transistor Compatible Siemens 224 PLC, Find details about China Compatible Siemens, High Speed from Cotrust PLC 224e 14di/10do Transistor Compatible Siemens 224 PLC
Physical Features | Transistor | ||||||||
Size(W×H×D) | 137×80×62mm | ||||||||
Power dissipation | 7W | ||||||||
Power supply | DC:20.4 to 28.8V | AC:85V~265V | |||||||
Rated power supply | 24VDC | 220VAC | |||||||
Memory Features | |||||||||
Program memory | 12KB, expandable to 16KB | ||||||||
Data memory | 8KB | ||||||||
Super capacitor | About 112 hours(typical) | ||||||||
External battery (Optional) | About 200 days (typical) | ||||||||
General Features | |||||||||
Timers total 1ms 10ms 100ms | 256 4 16 236 | ||||||||
Counters total | 256(back up by super capacitor) | ||||||||
Internal memory bits | 256(back up by super capacitor) | ||||||||
Stored permanently on power down | 112 | ||||||||
Time Interrupts | 2 with 1ms resolution | ||||||||
Edge Interrupts | 4 rising edges and/ or 4 falling edges | ||||||||
Analog adjustment | 2 with 8 resolution | ||||||||
Boolean execution speed | 0.15µs | ||||||||
Float execution speed | 8µs | ||||||||
Clock | embedded | ||||||||
Integrated Communication Function | |||||||||
Communication Interface | 2 communication ports ,PORT0:PPI port,RS485;FPORT0:freeport,RS485 PWL | ||||||||
PPI baud rates | 9.6, 19.2 and 187.5k | ||||||||
Freeport baud rates | 1.2kbaud to 115.2k | ||||||||
Maximum cable length per segment Isolated repeater applied Isolated repeater unapplied | When it is 1000 m, baud rate is 187.5k; when it is 1200 m, 38.4k. 50 m | ||||||||
Maximum number of stations | 32 stations per segment,126 stations per network | ||||||||
Maximum number of masters | 32 | ||||||||
Point to point (PPI Master Mode) | Yes(NWTR/NETW), 8 total, 2 reserved | ||||||||
I/O Features | |||||||||
Number of integrated digital inputs | 14 | ||||||||
Input type | Sink/Source | ||||||||
Number of integrated digital outputs | 10 | ||||||||
Output type | Solid-MOSFET | Relay dry contact | |||||||
Digital I/O mapping domain | 256(128 inputs/128 outputs ) | ||||||||
Analog I/O mapping domain | 64(32 inputs /32 outputs ) | ||||||||
Maximum number of expandable I/O modules | 7 | ||||||||
Maximum number of digital I/O | 230 | ||||||||
Maximum number of analog I/O | 56AI / 28AO | ||||||||
Pulse catch inputs | 14 | ||||||||
High-speed counters Total Uniphase counters Bi-phase counters | 2(HSC0 and HSC1) 2×30KHz 2×20KHz | ||||||||
Digital Input Features | |||||||||
Number of integrated digital input | 14 | ||||||||
Input type | Sink/ Source (IEC Type 1/Source) | ||||||||
Rated voltage | 24V DC | ||||||||
Maximum continuous permissible voltage | 30V DC | ||||||||
Logical 1 Signal (minimum) Logical 0 Signal (Maximum ) | 18 VDC,2.5mA 5 VDC,1mA | ||||||||
Isolation(field side to logical circuit) Optical isolation(Galvanic) Isolation groups | Yes 500V AC,1 minute refer to the Terminal Identification | ||||||||
Simultaneous inputs | 14 | ||||||||
Maximum cable length Shielded Unshielded | 500 M(standard input) 50 M(high-speed counters input) 300 M(standard input) | ||||||||
Digital Output Features | |||||||||
Number of integrated digital output | 10 | ||||||||
Output type | Solid--MOSFET | Relay dry contact | |||||||
Rated voltage | 24VDC | -- | |||||||
Maximum rated current of each point Surge current (Max) | 0.75A 8A,100ms | 2A 5A,contacts closed | |||||||
Lamp load (Max) | 5W | 30WDC/200WAC | |||||||
On- state resistance | 0.3 ohm typical (Max :0.6 ohm ) | 0.2 ohm | |||||||
Delay (Max) off to on on to off | 2us(Q0.0, Q0.1),15us(others) 10us(Q0.0, Q0.1),130us(others) | 30ms(Max) | |||||||
High-speed Pulse Output | 2 Axis ×50KHz Can run instructions of motion control CPU like PTP/ Speed_ctrl etc.; do not support PTO/PWM instructions in the programming software. | -- | |||||||
Switching frequency(Max) | -- | 1HZ | |||||||
Mechanical life cycle | -- | 10 million times (Zero Load) | |||||||
Contact endurance | -- | 0.1 million times (Rated Load) | |||||||
Simultaneous output | 10 | ||||||||
Parallel output | Only when the outputs are in the same group | ||||||||
Maximum cable length Shielded Unshielded | 500M(Standard Input) 150M(Standard Input) |