China Cotrust Cth200 PLC Sm231 High Precision Analog Module Current Input, 8 Channels (231-1HF32) Programming Logic Controller, Find details about China Cotrust, Digital Input from Cotrust Cth200 PLC Sm231 High Precision Analog Module Current Input, 8 Channels (231-1HF32) Programming Logic Controller
Order Data
Model No. | Description | Order No. |
SM231 | SM231 High precision analog current input,8*16BIT, optocoupling isolation | CTH2 231-1HF32 |
Performance Parameters
Physical Features | |
Dimension(W×H×D) | 120.5×80×62mm |
Weight | 210g |
Power loss | |
Bus 5VDC | 25 mA |
L+ | 31mA |
L+ coil voltage range | 20.4~28.8V DC |
Power loss | 1 W |
Analog Input Features | |
Analog input | 8 |
Input type | Current input |
Scale range | |
input (unipolar) | 0~20mA;4~20mA |
Data word format | |
Unipolar, full range | 0~32000 |
Input resolution | |
Resolution | 0.000625 mA(0~20mA) 0.0005 mA(4~20mA)
|
Accuracy of measurement | 0.1% |
Input impedance | 250 Ω |
Common mode voltage
| 120V AC |
Common mode rejection | 90dB, 60Hz @ DC |
Input filter attenuation | 3db @ 325 HZ |
Diagnostic procedures | +24VDC power indicator, on: module power supply is normal, Off: The module has no power supply, and all channel data becomes 32766 The dialing switch is set incorrectly, and all channel data becomes 32767 |
Field site - logic | 500V AC |
Field site - DC 24V | 500V AC |
DC 24V -- logic | 500V AC |
Addressing mode | VW addressing |
Range selection and software configuration
[Range selection switch position]
The following table shows how to set the range of the SM231 8AI module with the DIP switch. Switches 1, 2 and 3 can select the analog input range. All inputs are set to the same analog input range. In the following table, ON means connection and OFF means no connection. It is important to note that unused DIP switches SW4 ~ SW6 must be set to the OFF position.
Single polarity | Full scale input | Resolution | ||
SW1 | SW2 | SW3 | ||
ON | OFF | ON | 0-10V | 300μV |
ON | OFF | 0 - 5V | 150μV | |
Bipolar | Full scale input | Resolution | ||
SW1 | SW2 | SW3 | ||
OFF | OFF | ON | ± 5V | 150μV |
ON | OFF | ± 2.5 V | 75μV |
[Software Configuration]
For the SM231 8AI× 16-bit analog input module, its reading is in VW, not AIW, the relative position of the module is different, the corresponding address is different. The address calculation formula is as follows:
X (VWx) = slot number × 64 + input channel number × 2
The slot number corresponds to the module's installation location, with the first extension slot next to the CPU being 0, the second extension slot being 1, and so on. There are 8 input channels, from A to G, and the corresponding numbers are 0 to 7.
VWxx | Channel 0 | Channel 1 | Channel 2 | Channel 3 | Channel 4 | Channel 5 | Channel 6 | Channel 7 |
Slot 0 | VW0 | VW2 | VW4 | VW6 | VW8 | VW10 | VW12 | VW14 |
Slot 1 | VW64 | VW66 | VW68 | VW70 | VW72 | VW74 | VW76 | VW78 |
Slot 2 | VW128 | VW130 | VW132 | VW134 | VW136 | VW138 | VW140 | VW142 |
Slot 3 | VW192 | VW194 | VW196 | VW198 | VW200 | VW202 | VW204 | VW206 |
Slot 4 | VW256 | VW258 | VW260 | VW262 | VW264 | VW266 | VW268 | VW270 |
Slot 5 | VW320 | VW322 | VW324 | VW326 | VW328 | VW330 | VW332 | VW334 |
Slot 6 | VW384 | VW386 | VW388 | VW390 | VW392 | VW394 | VW396 | VW398 |
Note: Because the offset address of TD2X text display is also in VW0, so If you need to use Td2X text display in your system, please don't put the EM231 8AI×TC module in slot 0, or the TD2X will not work normally. Siemens TD200 text displayer is same as TD2X.