Gas Generator for Power Station

China Gas Generator for Power Station, Find details about China Syngas Generator, Jichai from Gas Generator for Power Station

Model NO.
1000GF-T
Standard
Standard
Rpm
1000
Trademark
Jichai
Transport Package
Wood Cases Packing
Specification
800GF-N
Origin
China
HS Code
85022000
Model NO.
1000GF-T
Standard
Standard
Rpm
1000
Trademark
Jichai
Transport Package
Wood Cases Packing
Specification
800GF-N
Origin
China
HS Code
85022000
500kw Gas Generator for Power Station

Jichai Brand Generator is designed and manufactured to be high quality, long usage life, easy operation, low maintenance cost, high intelligence with low engine speed, low fuel consumption, low gas quality requirement, tough environmental adaptability, high stability and low fluctuation. The generator is desirable for industrial power solution.
 
Gas Generator for Power Station 500kw Bio gas engine generator

This 500kW Biomass Generator is equipped with M12V190ZL Gas engine as original power, and possesses the following outstanding characteristics and functions:
 
A) The output voltage can be 400V, 6300V, 10500V, reducing the initial investment and running cost.
B) Big bore of 190mm ensures its continuous constant power output.
C) Middle speed of 1000rpm ensures the service life.
D) Natural aspiration ensures the safety of coal bed methane delivery.
E) Easy maintenance and low noise.

500kw LNG CNG Natural Gas Syngas Genset Biogas CHP Unit  Biomass power plant Cogeneration

MAIN SPECIFICATIONS OF GAS GENERATOR SET
Model500GFM Gas Engine ModelM12V190ZL
Rated power500kw Alternatorsynchronous brushless generator
Rated voltage400 V Insulation classF
Rated speed1000rpm Voltage regulationAutomatic
Rated frequency50Hz Class of protection IP22
Rated current1281A Cooling methodWater cooling with radiator and fan
Power factor0.8 Lagging Dimension (mm)5750×2650×2500mm
Control modeElectric control Net Weight (kg)14500 Kg

MAIN ELECTRICAL PERFORMANCE OF THE GAS GENERATOR   

500kw LNG CNG Natural Gas Syngas Genset Biogas CHP Unit  Biomass power plant Cogeneration
Voltage
Stabilized regulationInstantaneous regulationRecovery timeFluctuation
±2.5%+20%2 S1%
Frequency
Stabilized regulationInstantaneous regulationRecovery timeFluctuation
0-5% adjustable≤±10%< 7 S1%

MAIN SPECIFICATIONS OF GAS ENGINE

500kw LNG CNG Natural Gas Syngas Genset Biogas CHP Unit  Biomass power plant Cogeneration
TypeM12V190ZL
Number of cylinders12
Cylinder ArrangementVee,60°
Cylinder diameter x stroke 190×210 mm
Total Displacement71.5 L
Intake TypeTurbocharged and inter-cooled
Rated Power,kW750
Rated Speed,r/min1000
Biogas input pressure,kPa5-10
Exhaust Temperature before turbocharger,ºC≤650
 
 Gas Generator for Power StationGas Generator for Power Station
SAFETY AND PROTECTION DEVICE OF THE GENSETS
 
Output voltage too low/too high alarm and stopSingle phase connection trouble alarm and stop
Frequency too high/too low alarm and stopCooling water temp high alarm
Reverse power alarm and break brakeLubrication oil temp too high alarm
Overload alarm and break brakeLubrication oil pressure too low alarm and stop
Over speed alarm and stopBattery voltage too low alarm
Blast prevention of air inlet and crankcaseGas leaking protection
 
 
500kw LNG CNG Natural Gas Syngas Genset Biogas CHP Unit Cogeneration
CONTROL PANEL
Control panel is panel type, vertical structure, model is GPL500. Control panel is equipped with meters showing various parameters of operating status, automatic air switch and timer. All of the electric cells possess three-proof functions.

The Generator possesses the following automatic monitoring and protective functions:

A) Audio or visual alarm for:
-   High oil and water temperature
-   Low oil pressure
-   Over current
-   Short circuit
-   Over-speed
-   Reverse power
B) Shut-off for:
-   Low oil pressure
-   Over-speed
-   Short circuit
-   Over-speed
-   Reverse power
C) Trip-off for:
-   Over-current
-   Short circuit
-   Reverse power
The generator can not only supply power directly to load but also can be paralleled running.
Gas Generator for Power StationGas Generator for Power Station
OPTIONAL DEVICE     
Steel Soundproof Container (sound attenuated canopy)  More Technical date,feel free to contact jichaipower @ outlook.  com
CONTAINERIZED GENERATOR SET  (OPTIONAL)
Framework adopts high strength steel and I bar to form the base. The sound-proof container is equipped with explosion-proof lighting,air blower, combustible gas leakage alarm etc. to satisfy protection requirements.
Noise reduction measures should meet national standard requirements, which requires noise should not be more than 85db at 1m distance away from the generator.
Flat bed radiator is laid on the roof of the container which requires high quality of the container strength

500kw LNG CNG Natural Gas Syngas Genset Biogas CHP Unit  Biomass power plant Cogeneration

Gas Generator for Power Station
CHP/ Cogeneration/CCHP Trigeneration


In order to make full use of total thermal energy from combustible gas, customer requires CHP system on the basis of power generation use. This system consists of heat exchanger, liquid supply pump or hot liquid circulation pump, valves and insulation liquid pipe.
The above components form a circulation system, with liquid  supply pump or hot liquid circulation pump as power source.
It adopts heat exchanger and boiler with adding antifreezer to produce hot water for production and daily use.
Heat recovery boilers waste heat of exhaust  
In order to make full use of the exhaust heat of the unit and improve the comprehensive utilization rate of gas, a waste heat recovery boiler is added to the exhaust system to recover the exhaust heat and generate hot water (70 to 90°C) or saturated steam (1MPa). The waste heat can be used for production or life Use heat.
Heat recovery boilers waste heat of hot water
Generator with a semi-open circulation cooling system, the internal circulating high-temperature water (cylinder jacket water) transfers heat to the external circulating high-temperature water through the heat exchanger. The external circulating high-temperature water pipe can be directly introduced into heating equipment such as heating, where the heat is exchange to increase the temperature in the fermenter.
  This makes full use of the heat of the engine cooling water and improves the overall utilization rate.
Gas Generator for Power Station
ATS and Synchronization Parallelling Panel
Gas Generator for Power Station
Oil and Water Heater

Gas Generator for Power StationGas Generator for Power StationGas Generator for Power StationGas Generator for Power Station