China Digital Dimmable Double Ended HPS Dehps 1000W 1200W Lighting Fixture 277V, Find details about China De, HPS from Digital Dimmable Double Ended HPS Dehps 1000W 1200W Lighting Fixture 277V
Electronic ballast for high pressure sodium lamps | SPECIFICATION | ||
Model number | TPS1200W | ||
Dimming mode | Maual / RJ11 remote control | ||
Rated Output wattage | >1170W, dimming level 6/7/8/9/10/11/1200W | ||
Wiring dimming wattage (See LED tube code in annex) | Manual dimming does not function when dimming wire is plugged-in. Voltage from dimming wire: 2V±0.3V= Off, >2.5V±0.3V=On, 2.5~12Vdc reflects to 635W~1270W(±10%) with linearity<8% | ||
Input V/C (range, 200/240Vac) | 200V/6.4A | ||
240V/5.3A | |||
Max 6.6A / fuse 10A | |||
Output frequency | >70kHz | ||
Efficiency | >93% @ 240Vac | ||
Ignition voltage | <4.5KV | ||
Required lamp Voltage | 220V | ||
Input frequency | 50 and 60Hz compatible | ||
PF | >0.97 | ||
OCV | >300V | ||
THD | <10% | ||
CCF | <1.7 | ||
Max distance from ballast to lamp | 3m | ||
Operating temperature range | -20~40ºC | ||
Max case temperature | 90ºC | ||
Safety and regulation | IEC 61347 | ||
EMC | based on FCC part 18 A | ||
Protection against | |||
Short-circuit | Yes | ||
Open-circuit | Yes | ||
Ignition failure | Yes | ||
Overheated | Yes | ||
EOL | Yes | ||
Soft-start | Yes | ||
Lamp model or ANSI | 1000W double ended HPS lamp x1 | ||
Weight | 3.6kg | ||
Dimensions | 230*256.4*98.9mm | ||
Vantilation | Natural | ||
APPLICATIONS | |||
Grow lighting, Outdoor lighting, Street lighting, Tanning | |||
Plug-and-play design, triangle wave output, | |||
Wide AC input range | SMART FEATURES | ||
Indicator definition | |||
Status code | Status | ||
F flicks | Soft-Off | ||
A flicks | Network standby | ||
A on | Network standby | ||
F on | Step dimming | ||
1 flicks | Power on | ||
2 on | Over voltage | ||
3 on | Low voltage | ||
4 on | Over heated | ||
5 on | Output open | ||
6 on | Output short | ||
7 on | EOL |