China Sweden Volvo 200kw Diesel Generator Set, Find details about China Generator, Diesel Generator from Sweden Volvo 200kw Diesel Generator Set
Diesel Generator Set Data | |
Manufacturer: | Jiangsu Starlight Electricity Equipments Co.,Ltd. |
Set Type: | XG-220GF |
Prime Power: | 220KW/275KVA |
Rated Current: | 396(A) |
Rated Frequency: | 50(Hz) |
Start-up time: | 5~6(s) |
Power Factor: | 0.8(Lag) |
Rated Voltage: | 400/230(V) |
Standard Features | |
|
Diesel Engine Data | |||||||||
Manufacturer: | VOLVO | ||||||||
Model: | TAD734GE | ||||||||
Standby/Prime Power: | 250KW/225KW | ||||||||
Rated Speed: | 1500(r/min) | ||||||||
Cycle: | 4 stroke | ||||||||
Cylinder Arrangement: | 6 in line | ||||||||
Displacement: | 7.15L | ||||||||
Bore and Stroke: | 108*130(mm) | ||||||||
Compression Ratio: | 17:1 | ||||||||
Governor Type: | Electronic | ||||||||
Start battery voltage: | 24V DC | ||||||||
Air Intake System | |||||||||
Air Intake System: | Turbo, Air/Air Cooling | ||||||||
Max Intake Restriction: | 3kpa | ||||||||
Burning Capacity: | 16.3m3/min | ||||||||
Air Flow: | 318 m3/min | ||||||||
Exhaust System | |||||||||
Exhaust Gas Flow: | 33.4m3/min | ||||||||
Exhaust Temperature: | 550ºC | ||||||||
Max Back Pressure: | 10kPa | ||||||||
Fuel System | |||||||||
Fuel System: | Elec. Injection, Elec. Fuel System | ||||||||
100%( Prime Power) Load: | 196g/kwh | ||||||||
50%( Prime Power) Load: | 211g/kwh | ||||||||
Oil System | |||||||||
Total Oil Capacity: | 29L | ||||||||
Oil Consumption: | ≤0.01L/h | ||||||||
Engine Oil Tank Capacity: | 24L | ||||||||
Oil Pressure at Rated RPM: | 420-450kPa | ||||||||
Cooling System | |||||||||
Cooling Way: | Water-cooled | ||||||||
Total Coolant Capacity: | 32L | ||||||||
Thermostat: | 83-98ºC | ||||||||
Max Water Temperature: | 103ºC | ||||||||
Alternator Data | |||||||||
Manufacturer: | STARLIGHT/ STAMFORD/ SIEMENS/ MARATHON/ ENGGA / KEPU | ||||||||
Excitation Mode: | Brushless and self- exciting | ||||||||
Number of phase and Access Act: | 3-phase 4-wire | ||||||||
Connecting Type: | "Y" type connecting | ||||||||
Alternator Capacity: | 250KVA | ||||||||
Alternator Efficiencies: | 95% | ||||||||
Overload: | (PRP)110% load can run 1h | ||||||||
Protection Level: | IP22-IP23 | ||||||||
Insulation Class, Temperature Rise: | H/H | ||||||||
Telephone Influence Factor (TIF): | <50 | ||||||||
THF: | <2% | ||||||||
Voltage Regulation, Steady State: | ≤±1% | ||||||||
Air Cooling Flow: | 0.58m3/s | ||||||||
Altitude: | ≤1000m | ||||||||
Genset Electrical Performance | |||||||||
Voltage Regulation: | ≥±5% | ||||||||
Voltage Regulation, Stead State: | ≤±1% | ||||||||
Sudden Voltage Warp (100% Sudden Reduce): | ≤+25% | ||||||||
Sudden Voltage Warp (Sudden Increase): | ≤-20% | ||||||||
Voltage Stable Time (100% Sudden Reduce): | ≤6S | ||||||||
Voltage Stable Time (Sudden Increase): | ≤6S | ||||||||
Frequency Regulation, Stead State: | ≤5% | ||||||||
Frequency Waving: | ≤1.5% | ||||||||
Sudden Frequency Warp (100% SuddenReduce): | ≤+12% | ||||||||
Sudden Frequency Warp (Sudden Increase): | ≤-10% | ||||||||
FrequencyRecoveryTime(100%SuddenReduce): | ≤5S | ||||||||
FrequencyRecoveryTime(Sudden Increase): | ≤5S |