12KV Solid Insulated Switchgear
Specification:
Load switchgear parameters
NoItemUnitParameter
1Type of interrupter Vacuum
2Rated currentA630
3Rated short time withstand currentKA25
4Rated short durationS4
5Rated peak withstand currentKA63
6Rated short circuit closing currentKA63
7Rated short-circuit closing timesTime3
8Rated active load breaking currentA630
9Rated cable charging breaking currentA10
10Opening average speedm/s1.1±0.2
11Closing average speedm/s0.8±0.2
12Closing bounce timems<=2
13Sub-gate contact rebound amplitudemm<=3
14Closing timems<=30-70
15Opening timems<=20-50
16Three different phases <=2
17Main circuit resistanceμΩ<=120
18Mechanical lifeTime10000
 
Breaker parameters
NoItemUnitParameter
1Type of interrupter Vacuum
2Rated currentA630
3Rated short circuit breaking currentKA20/25
4Rated short durationTime30
5Rated peak withstand currentKA63
6Rated short circuit closing currentKA63
7Opening average speedm/s1.1±0.2
8Closing average speedm/s0.8±0.2
9Closing bounce timems<=2
10Sub-gate contact rebound amplitudemm<=2
11Closing timems30-70
12Opening timems20-50
13Three different phases <=2
14Out of phase fault test currentKA21.7
15Out of phase fault test voltageV12
16Capacitive current breaking test currentKA25
17Capacitive current breaking test voltageV12
18Main circuit resistanceμΩ<=120
19Mechanical lifeTime10000
 
Combination of electrical parameters
NoItemUnitParameter
1Type of interrupter Vacuum
2Rated currentA125
3Rated short circuit breaking currentKA31.5
4Rated transfer currentA3150
 
Disconnect switch parameters
NoItemUnitParameter
1Rated currentA630
2Main circuit resistanceμΩ<=20-50
3Rated short time withstand currentKA25
4Rated short durationS4
5Rated peak withstand currentKA63
6Mechanical lifeTime3000
 
Earthing switch parameters
NoItemUnitParameter
1Rated short time withstand currentKA25
2Rated short durationS4
3Rated peak withstand currentKA63
4Mechanical lifeTime3000

Product description:
SIDC 16 Solid Insulated Switchgear is 12KV three-phase AC 50Hz , the single bus and the bus section complete sets of power distribution unit of the system. By adopting the technology of solid insulation, the vacuum arcing chamber combination with the primary loop as a whole, realize the fully insulation, fully sealed, maintenance-free. Modular design, small size,no SF6 gas, meet the requirements of environmental protection.

Features:
Environment protecting, do not use the SF6 gas;
Anti harsh environment, anti condensation, frost, fog, salt contamination,
corrosion resistance etc;
Compact structure, small size, easy to install;
Modular design, flexible expansion;
Smart grid compatible, optional automation terminal, to meet the requirements of smart grid upgrade.


Applicable conditions:
Altitude:≤2000m
Ambient temperature:-35ºC~+40ºC
Relative humidity:
Daily average≤95%
Monthly average≤90%
Seismic capacity:8 degrees 
Altitude≤2000m
Ambienttemperature-35ºC-+40ºC
Seismic Capacity8 degree
Sidc16-12 Solid Insulated Ring Network Cabinet for Medium Voltage for Subway
Sidc16-12 Solid Insulated Ring Network Cabinet for Medium Voltage for Subway
Sidc16-12 Solid Insulated Ring Network Cabinet for Medium Voltage for Subway
Sidc16-12 Solid Insulated Ring Network Cabinet for Medium Voltage for Subway
Sidc16-12 Solid Insulated Ring Network Cabinet for Medium Voltage for Subway
Sidc16-12 Solid Insulated Ring Network Cabinet for Medium Voltage for Subway