20kVA Portable Silent Type Diesel Generator with Chinese Yangdong Engine, Find details about China Electric Generator, Power Generator from 20kVA Portable Silent Type Diesel Generator with Chinese Yangdong Engine
Powered by Yangdong 50HZ 400/230 V 10-94KVA | ||||||||||||
Model | LTP | PRP | Engine | Fuel Cons. | Cylinder | Displacement | Gov. | Dimention | Weight | |||
KVA/KW | KVA/KW | Model | Origin | L/H(100%) | L | L*W*H(MM) | KGS | |||||
MC10YD | 10 | 8 | 9 | 7 | YD380D/10KW | CN | 2.2 | 3L/NA | 1.357 | M | 1550*760*1250 | 460 |
MC14YD | 14 | 11 | 13 | 10 | YD385D/12KW | CN | 2.7 | 3L/NA | 1.532 | M | 1550*760*1250 | 480 |
MC17YD | 17 | 13 | 15 | 12 | YD480D/14KW | CN | 3.5 | 4L/NA | 1.809 | M | 1650*760*1250 | 491 |
MC19YD | 19 | 15 | 18 | 14 | YND485D/17KW | CN | 4.1 | 4L/NA | 2.156 | M | 1650*760*1250 | 512 |
MC25YD | 25 | 20 | 23 | 18 | YSD490D/21KW | CN | 5.2 | 4L/NA | 2.540 | M | 1760*760*1250 | 530 |
MC28YD | 28 | 22 | 25 | 20 | Y490PD/24KW | CN | 5.2 | 4L/NA | 2.670 | M | 1760*760*1250 | 560 |
MC33YD | 33 | 26 | 30 | 24 | Y4100D/32KW | CN | 6.8 | 4L/NA | 3.707 | M | 1880*760*1300 | 690 |
MC41YD | 41 | 33 | 38 | 30 | Y4105D/38KW | CN | 9.2 | 4L/NA | 4.100 | M | 1880*760*1300 | 795 |
MC55YD | 55 | 44 | 50 | 40 | Y4102ZLD/48KW | CN | 9.4 | 4L/TC | 3.875 | M | 1880*760*1300 | 805 |
MC66YD | 66 | 53 | 60 | 48 | Y4105ZLD/55KW | CN | 11.5 | 4L/TC | 4.100 | E | 1880*760*1300 | 823 |
MC74YD | 74 | 59 | 68 | 54 | YD4EZLD/63KW | CN | 16.5 | 4L/TC | 4.100 | E | 1970*730*1430 | 890 |
MC94YD | 94 | 75 | 85 | 68 | Y4110ZLD/80KW | CN | 20.9 | 4L/TC | 4.484 | E | 2050*900*1430 | 1050 |
General Feature | ||||||||||||||||||
♦ Assembled by diesel engine and Brushless alternator. | ||||||||||||||||||
Three filters as standard, fuel and water separator as optional. | ||||||||||||||||||
♦ Radiator and fan with safety guard. | ||||||||||||||||||
♦ Single bearing alternator IP 23, Insulation Class H. | ||||||||||||||||||
♦ Heavy duty steel as base frame and 8hrs operation base fuel tank. | ||||||||||||||||||
♦ Automatic control panel and 3 poles circuit breaker, internal cable. | ||||||||||||||||||
♦ 12V or 24V battery, battery wires. | ||||||||||||||||||
♦ Battery and float battery charger as standard supply scope. | ||||||||||||||||||
♦ Fuel level indicator in meter and panel | ||||||||||||||||||
♦ Optional soundproof canopy, ATS, synchronization panel, movable trailers. |
Genset Main Technical Data | ||||||||||||||||||
Genset Model | MC10YD-MC94YD | |||||||||||||||||
Prime Power | 7kW-68kW/9kVA-85kVA | |||||||||||||||||
Standby Power | 8kW-75kW/10kVA-94kVA | |||||||||||||||||
Frequency/Speed | 50Hz/1500rpm | |||||||||||||||||
Standard Voltage | 230/400V, Others as Application Requested | |||||||||||||||||
Phases | Three phases, four wires | |||||||||||||||||
Dimensions(L×W×H)mm | Open/Silent dimension as below list | |||||||||||||||||
100% Fuel Cons. (L/H) | 3.9~77.6 | |||||||||||||||||
Base Fuel tank (hour) | 8~10 |
Standard Accessories | ||||||||||||||||||
*Auto Control Panel | *Starting Motor | |||||||||||||||||
*Main Ciruit Breaker | *Exhaust silencer | |||||||||||||||||
*Fuel tank | *Starting battery | |||||||||||||||||
*Base Frame | *Float battery charger | |||||||||||||||||
*Filter | *Flange |
Icon | Indicator Light | Reason | Fault Analysis |
Low oil pressure alarm | Low oil pressure alarm | When oil pressure does not reduce normally, the light is on. | -General because of a lack of oil or lubrication system failure caused by (refueling or replacing the oil filter) -When occurs this fault should automatically shutdown generator sets immediately. |
High water temperature alarm | High water temperature alarm | When the water temperature has risen to a level higher than or equal to the sensor setting, the light is on. | -General because of a lack of water or oil shortage, or overload. -When occurs this fault should automatically shutdown generator sets immediately. |
Low fuel level alarm | Low fuel level alarm | When a fuel level has been detected by the sensor fitted to the daily tank, the light is on. | -General because of a lack of water or oil shortage, or overload. -When occurs this fault should automatically shutdown generator sets immediately. |
Battery charger fault alarm | Battery charger fault alarm | If the charging system has fault, when engine running, the light is off. | -Battery charging system fault caused. -The light is on at the initial start, when the charger reaches a certain speed, the light is off. -This failure will not lead to automatic shutdown generating units. |
Crank failure alarm | Crank failure alarm | When the generator set failed three times (or six times) in a row starting, the light is on. | -Oil supply system or re-start the system failure caused. |
Overload or breaker tripping alarm | Overload or breaker tripping alarm | When overloading or Short circuit, the light is on. Tripping circuit breakers cause generator set load out. | -In this fault, it need to load or unload some parts to eliminate short-circuit, and then re-close the circuit breaker. |