Portable Infant/Emergency Multi-parameter Patient Monitor PDJ-3000H

Features:
1. Displayer: 8.4" color TFT LCD screen with maximum 7-waveform display.
2. Battery: Rechargeable high-energy built-in battery can be used around 3 hours after fully charged
3. Advanced streamline outline design, portable, compact, lightweight
4. Operating menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, Arabic, Russian, Italian, etc.
5. Easy operation with user friendly menu structure design and rotary dial
6. Against & eliminate ESU interference & defibrillation, no need to disconnect the monitor from the patient in process of defibrillating.
7. Three-application mode: Monitoring, diagnosis, operating.
8. WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible
9. Optional built-in wireless networking function
10.360 hours data storage.
Specifications:
Temperature (surface and rectal)
Measurement range: 0 – 50.0 degree
Accuracy: ± 0.1degree
Resolution: 0.1 degree
response time: ≤ 3 min.
 
ECG
Input: 5 wires ECG cable
Lead section:I,II,III/ aVR, aVL, aVF/ V
Gain(mm/mV): 1/4,1/2,1,2,4
Frequency response: Diagnosis    0.05 - 100Hz
                            Monitor    0.5 - 40 Hz
                          Surgery      1.0 - 25 Hz
Sweep speed(mm/sec): 3.125,6.25,12.5, 25, 50
Heart rate range: 30-254 BPM
Heart rate accuracy: ± 1 %
ST segment deviation analysis:   -0.8-+0.8mV
ST accuracy:  ±0.02mv 
 
Respiration Rate(RA-LL impedance and nasal cavity)
Measurement range: 0 - 156 BPM(adult)
Accuracy: ± 1 BPM or 5 %
Resolution: 1 BPM
 
Pulse Rate
SPO2 measurement range: 0 - 100 %
Resolution: 1 %
Pulse measurement range: 30- 254BPM
Accuracy: ± 2 %
Resolution: 1 BPM 
 
NIBP (Non-invasive blood pressure) 
Measurement type : adult, pediatric, neonatal
Measurement range: Systolic 4.0 - 37.0 kPa
                           Diastolic   1.3 - 33.0 kPa
                           Mean         2.6 - 35.0 kPa
Accuracy : ± 0.4 kPa or 5 %
Resolution: 0.1 kPa
Protection: over pressure
 
IBP(Invasive blood pressure) (with venous punch) 
(Option)
Measurement range: -1.3~40kPa (-10~300mmHg)
Channel: 2 channel
Transducer sensitivity: 5MV/V/mmHg
Unit display: KPa or mmHg selectable
 
Power requirements 
Input:  98~260 V AC,  50/60Hz
Consumption:    ≤ 80VA