China Capacitance Type Air Differential Pressure Sensor Under High Temperature, Find details about China Low Cost 3-Wire Metal Capacitive Pressure Sensor, Metal Capacitive Pressure Sensor from Capacitance Type Air Differential Pressure Sensor Under High Temperature
low price metal capacitance differential pressure sensor dp sensor cell used for pressure transmitter
Product description:
The medium pressure is transferred to the test diaphragm in the middle of δ room by the barrier diaph
ragm and Silicon oil, as the test diaphragm is tight flexible element, it produce displacement following
the pressure differential.
The displacement of the diaphragm and pressure differential are in direction proportion, the max disp
lacement is 0.1mm, It is tested by the by the capacitiveplat on the both side, Then the differential cap
acitor between the test diaphragm and capacitive board switched to standard output by the Circuit Cu
rrent.
Range
Product name | Code | Range |
capacitive pressure sensor | 4E | 0-6.2-37.4kPa |
5E | 0-31-186.8kPa | |
6E | 0-117-690kPa | |
7E | 0-345-2068kPa | |
8E | 0-1170-6890kPa | |
3E | 0-1.3-7.5kPa | |
9E | 0-3480-20680kPa | |
0E | 0-6890-41370kPa | |
2E | 0-0.125-1.5kPa |
Performance:
Item | Para meters |
Accuracy | ±0 . 1 % |
Stability | ±0 . 2% ( 12 mo n th s) |
Temp range | -40ºC ~+ 14 0 ºC |
Temp affect | ze ro erro r: ±0 . 25 %/ 55 ºC |
ra ng e erro r: ±0. 5 %/ 55 ºC | |
Static pressure | DP 13.8MPa HP 25MPa DR 6.9MPa |
Overpressure limit | AP GP 13.8MPa DR DP HP |
Diaphragm material | 316Lss Hastelloy C Tant alum |
Parameters:
Model | Stability | Temp limit | Pressure limit | Range |
AT3051DP | ±0 . 1 %UR L | -40~14 0 ºC | 13.79MPa | 1.3~6890KPa |
AT3051GP | ±0 . 1 %UR L | -40~14 0 ºC | 13.79MPa | 1.3~41370KPa |
AT3051DR | ±0 . 2 %UR L | -40~14 0 ºC | 6.9MPa | 0.125~1.5KPa |
AT3051HP | ±0 . 1 %UR L | -40~14 0 ºC | 31.02MPa | 6.2~2068KPa |
AT3051AP | ±0 . 1 %UR L | -40~14 0 ºC | 13.79MPa | 6.2~6890KPa |
AT3051LT | ±0 . 2 %UR L | -40~14 0 ºC |
| 635~70380mmH2O |
AT3051DP | ±0 . 1 %UR L | -40~14 9 ºC | 13.79MPa | 635~6895KPa |
AT3051GP | ±0 . 1 %UR L | -40~14 9 ºC | 51.71MPa | 635~6895KPa |
AT1151DP | ±0 . 1 %UR L | -40~14 0 ºC | 13.79MPa | 1.3~6890KPa |
AT1151GP | ±0 . 1 %UR L | -40~14 0 ºC | 51.71MPa | 1.3~41370KPa |
AT1151DR | ±0 . 2 %UR L | -40~14 0 ºC | 6.9MPa | 0.125~1.5KPa |
AT1151HP | ±0 . 1 %UR L | -40~14 0 ºC | 31.02MPa | 6.2~2068KPa |
AT1151AP | ±0 . 1 %UR L | -40~14 0 ºC | 13.79MPa | 6.2~6890KPa |
AT1151LT | ±0 . 1 %UR L | -40~14 0 ºC |
| 635~70380mmH2O |
AT1151DP | ±0 . 1 %UR L | -40~14 0 ºC | 13.79MPa | 6.2~6890KPa |
AT1151GP | ±0 . 1 %UR L | -40~14 0 ºC | 13.79MPa | 6.2~6890KPa |
AT2088 | ±0 . 5 %UR L | -40~12 0 ºC |
| -0.1~40KPa |
SP | ±0 . 5 %UR L | -20~80 ºC |
| -0.1~40MPa |
SH-A | ±0 . 5 %UR L | -20~80 ºC |
| 0~200m |