Eberry Vs1-24 High Voltage Indoor Vacuum Circuit Breaker Vcb 24kv 630A 1250A 25ka 31.5ka P=275

China Eberry Vs1-24 High Voltage Indoor Vacuum Circuit Breaker Vcb 24kv 630A 1250A 25ka 31.5ka P=275, Find details about China Vcb, Vacuum Circuit Breaker from Eberry Vs1-24 High Voltage Indoor Vacuum Circuit Breaker Vcb 24kv 630A 1250A 25ka 31.5ka P=275

Model NO.
VS1-24
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Certification
ISO9001-2000, CQC
Rated Voltage
24kv
Rated Frequency
50/60Hz
Rated Current
630A-1250A
Phase Distance
275mm
Trademark
Eberry
Transport Package
Plywood Box
Origin
Yueqing, Zhejiang
Model NO.
VS1-24
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Certification
ISO9001-2000, CQC
Rated Voltage
24kv
Rated Frequency
50/60Hz
Rated Current
630A-1250A
Phase Distance
275mm
Trademark
Eberry
Transport Package
Plywood Box
Origin
Yueqing, Zhejiang
    
Eberry Vs1-24 High Voltage Indoor Vacuum Circuit Breaker Vcb 24kv 630A 1250A 25ka 31.5ka P=275
Eberry Vs1-24 High Voltage Indoor Vacuum Circuit Breaker Vcb 24kv 630A 1250A 25ka 31.5ka P=275
Eberry Vs1-24 High Voltage Indoor Vacuum Circuit Breaker Vcb 24kv 630A 1250A 25ka 31.5ka P=275
Eberry Vs1-24 High Voltage Indoor Vacuum Circuit Breaker Vcb 24kv 630A 1250A 25ka 31.5ka P=275


Description:

VCB-24 series solid-sealed indoor vacuum circuit breaker is an indoor high-voltage switchgear for three-phase power system with rated voltage of 24kV and frequency of 50 Hz. It is used as protection and control appliance due to vacuum circuit breaker. The special advantages are especially suitable for frequent operations requiring rated current or multiple short-circuit currents.

VCB-24 series solid-sealed indoor vacuum circuit breakers are fixedly mounted, mainly used for fixed switchgear. The circuit breaker can be used alone or in ring power supply, box transformer or various non- power supply system.

 
NOItemUnitTechnical Parameters
1Rated voltageKV24
2Rated short-duration power frequency withstand voltageKV65/79(Interphase, ground/fracture)
3Rated lightning impulse withstand voltageKV125/145(Interphase, ground/fracture)
4Rated frequencyHz50
5Rated currentA630 1250

630 1250

630 1250

6Rated short-circuit breaking currentKA20/2531.531.5
7Rated short-time withstand currentKA20/2531.531.5
8Rated short circuit durationS4
9Rated peak withstand currentKA50/6380100
10Rated short circuit closing currentKA50/6380100
11Secondary circuit power frequency withstand voltage (1min)V2000
12Rated single / back to back capacitor group breaking currentA630/400(40kA:800/400)
13Rated capacitor bank closing currentKA12.5 (frequency is not greater than)
14Mechanical lifeTIMES20000
15Rated current breaking times (electrical life)TIMES20000
16Rated short circuit current breaking timesTIMES50(40KA≤30)
17Dynamic and static contacts allow wear cumulative thicknessMM3
18Energy storage timeS≤10
19Contact opening distanceMM16±1
20Overtravel 3.5±0.5
21Contact closing bounce timeMS≤2(40KA≤3)
22Three-phase split/closed periodMS≤2
23Average opening speed (contacts are separated by -8mm)M/S1.5±0.2
24Average closing speed (8mm - contact closure)M/S0.8±0.2
25Main conductive loop resistanceμΩ
≤50(630A)≤45(1250A)
≤40 (1600,2000A)≤35 (2500A or more)
26Rated operation sequence 0-0.3s-Co-180s-Co