Class I Iimp10/350 25ka UC 255V Tt 3+1 System Sparkgap Pluggable Power Surge Lightning Protection Device

China Class I Iimp10/350 25ka UC 255V Tt 3+1 System Sparkgap Pluggable Power Surge Lightning Protection Device, Find details about China Surge Lightning Protector, Lightning Protector from Class I Iimp10/350 25ka UC 255V Tt 3+1 System Sparkgap Pluggable Power Surge Lightning Protection Device

Model NO.
BT P BCM 25 RM/3+N
Shape
Long Square
Material
Plastic
Certification
ROHS, ISO9001, Ce
Brand
Telebahn
Rated Voltage UC
255V
in 8/20us
50ka
Imax 8/20us
75ka
Iimp 10/350us
25ka
up
1.5kv
Trademark
Telebahn
Transport Package
in Cartons
Specification
55*32*27cm/carton size
Origin
China
HS Code
8536300000
Model NO.
BT P BCM 25 RM/3+N
Shape
Long Square
Material
Plastic
Certification
ROHS, ISO9001, Ce
Brand
Telebahn
Rated Voltage UC
255V
in 8/20us
50ka
Imax 8/20us
75ka
Iimp 10/350us
25ka
up
1.5kv
Trademark
Telebahn
Transport Package
in Cartons
Specification
55*32*27cm/carton size
Origin
China
HS Code
8536300000

Product introduction
Summary:
BT P BCM 25 RM/3+N is for installation at LPZ 0A-1 or higher, protecting low voltage equipment against lightning and surge damages, especially designed for TT/TN-S system ("3+1" circuit), applied in SPD Class I+II (Class B+C) for various power supply system of lightning current surge protection. Designed according to IEC 61643-11/GB 18802.1; YD/T 1235.1.
 

Main character
. Three-phase protection for TT/TN-S system ("3+1" circuit).
. Adopted hermetical GDT technology, high follow current extinguishing capability. 
. Extremely low voltage protection level, pluggable
. Double thermal disconnection device, providing more reliable protection
. Multifunctional connection for conductors and busbars.
. Green window will change to red when fault occurs and also provide remote alarm control contact at the same time

Application
BT P BCM 25 RM/3+N is mainly for installing indoor main power distribution-box to discharge direct lightning current.   

 
Application environment
Temperature: -40ºC...+80ºC
Relative humidity: <=95% (25°C)

Parameter: 
Model NoBT P BCM 25 RM/3+N
Art.-No.  800 915
Rated voltage (max. continuous a.c voltage)UC255V (L-N), 255V (N-PE)
Lightning impulse current (10/350µs)Iimp100KA
Lightning impulse current (10/350µs) Iimp  25KA (L-N), 50KA (N-PE)
Max. discharge current (8/20µs)Imax  75KA (L-N), 75KA (N-PE)
Voltage protection level UP   ≤ 1.5KV (L-N), ≤ 1.5KV (N-PE) 
Follow current extinguishing capability at UcIf     32A fuse will not be triggered at 2KA rms
Response timeTA≤ 100ns
Max. back up fuse (L) 200A gL/gG
Max. back up fuse (L-L') 125A gL/gG
TOV voltageU T355V/5sec (L-N), 1200V/200ms
Operating temperature range (parallel wiring)TUP-40ºC...+80ºC
Cross-sectional area 35mm2 solid/50 mm2 flexible
Mounting on 35mm DIN rail
Enclosure material Purple module & Light grey base thermoplastic, UL94-V0
Degree of protection IP20
Dimension 8 mods
Type of remote signaling contact Switching contact
Switching capacityUN/INAC: 250V/0.5A  DC: 250V/0.1A, 125V/0.2A, 75V/0.5A
Cross-sectional area for remote signaling contact Max. 1.5mm2 solid/flexible
Test standardsIEC 61643-11; GB18802.1; YD/T 1235.1
Certification CE (LVD, EMC)
FAQ
Q: Are you a factory or a trade company?  
A: We are the factory.

Q: Where are your products distributed?   
A: Our products are distributed all over the world, Main market are Europe, North America, the United Arab Emirates, Africa and so on.


Q: Can I have a sample?   
A: Yes, but according to our company's policy, we provided free samples, while you should pay the freight fee; the sample can be delivered by TNT/DHL/UPS/FEDEX.


Q: Which port is the nearest from you?   
A: Guangzhou port or Shenzhen Port or Hong Kong port.


Q: What's your lead time?
A: Sample lead time: 3~5 working days. Mass production: usually 10~30days.

For big orders, honestly, it depends on the order quantity and designs.

Q: When can I get the price?
A: We usually quote within 24 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your email so that we will regard your inquiry as priority.
 
Q: Can you do the design for us?
A: Yes, we have a professional team having rich experience in molding design, electrical system developing and manufacturing. Please just tell us your ideas and we will help you to carry out your ideas into a perfect artwork. You can pay for the molding fee and own the mold by yourself or we can cooperate on the molding.

Q: OEM & ODM are accepted or not?
A: OEM&ODM are welcome. 

Class I Iimp10/350 25ka UC 255V Tt 3+1 System Sparkgap Pluggable Power Surge Lightning Protection Device
Class I Iimp10/350 25ka UC 255V Tt 3+1 System Sparkgap Pluggable Power Surge Lightning Protection Device
Class I Iimp10/350 25ka UC 255V Tt 3+1 System Sparkgap Pluggable Power Surge Lightning Protection Device


 


Class I Iimp10/350 25ka UC 255V Tt 3+1 System Sparkgap Pluggable Power Surge Lightning Protection Device
Class I Iimp10/350 25ka UC 255V Tt 3+1 System Sparkgap Pluggable Power Surge Lightning Protection Device
Class I Iimp10/350 25ka UC 255V Tt 3+1 System Sparkgap Pluggable Power Surge Lightning Protection Device