25ka Power Surge Protector, Surge Protective Device for Class I Power Supply

China 25ka Power Surge Protector, Surge Protective Device for Class I Power Supply, Find details about China Power Surge Protector, Surge Protective from 25ka Power Surge Protector, Surge Protective Device for Class I Power Supply

Model NO.
OMP-APK25/4
Shape
Cuboid
Material
Flame Retardant Material
Certification
ROHS, ISO9001
Brand
Omldeen
Trademark
OMLDEEN
Transport Package
Paper
Specification
144*90*65mm
Origin
Shenzhen, China
HS Code
8535400000
Model NO.
OMP-APK25/4
Shape
Cuboid
Material
Flame Retardant Material
Certification
ROHS, ISO9001
Brand
Omldeen
Trademark
OMLDEEN
Transport Package
Paper
Specification
144*90*65mm
Origin
Shenzhen, China
HS Code
8535400000
Product introduction
Omldeen surge protection device, SPD (also known as lightning arrester, lightning arrester, surge protector, overvoltage protector), with high lightning current capacity, is suitable for electromagnetic pulse (EMP) protection of TN-S, TN-C-S, TT, it and other power supply systems with AC 380V (50 Hz / 60Hz) and below. It is used at the junction of lpzoa or lpzb area and lpz1 area

Working principle
Surge protective device (SPD) is an indispensable device in the lightning protection of electronic equipment. Its working principle is that under normal conditions, the SPD is in a high resistance state, so as to ensure the normal operation of the power supply system; when the surge overvoltage and over-current appear on the system line, the resistance of SPD changes suddenly or continuously drops to low impedance, and SPD will conduct in nanosecond level immediately After the surge, the surge protection device will return to the high resistance state quickly, which will not affect the normal power supply of the system.

Features
1. Stable and reliable performance, suitable for different grid systems, more comprehensive protection, ns level response speed.
2. It can withstand 25kA (10 / 350 μ s) lightning current impact.
3. Flame retardant shell design, can be easily installed on 35mm electrical guide rail.
4. Energy saving, environmental protection, easy installation, no special maintenance.

The product should be used in the installation position
Omldeen class I series surge protective devices are suitable for lpzoa area or interface between lpzob area and lpz1 area in lightning stroke area. They are usually installed in parallel at the main distribution cabinet at the low-voltage household end of buried through pipe incoming line or floor distribution cabinet.
Typical applications: mobile communication base station, microwave communication bureau / station, telecommunication room, industrial factories and mines, civil aviation, finance, securities and other power systems, such as various power distribution stations, distribution rooms, distribution cabinets, switch boxes and other important and lightning prone equipment.

technical parameter
nameClass I surge protector
modelOMP-APK25
Experimental levelI
Protection modeL-PE,N-PE
Nominal operating voltage220~380V
Maximum continuous operating voltage 385V 50Hz/60Hz
Power supply protection level(1.2/50μs)≤2.2kV
Pulse withstand current25kA(8/20μs)
Lightning impulse current25KA(10/350μs)
Response time ≤25ns
Insulation impedance100MΩ
Access conductor cross section (L / N)≥10mm²
Access ground wire section (PE)≥16mm²
Selection of backup protection circuit breaker63A~125A
work environment-40ºC~+85ºC
relative humidity≤95%
install35mm standard electric guide rail
Shell materialReinforced flame retardant PBT
Protection levelIP20
Test basisGB18802.1,IEC61643-1

Precautions for installation of lightning arrester
1. The SPD should be installed in parallel. Generally, only one of the two terminals can be connected, or double connection mode (Kevin connection mode) can be used. The connecting wire shall be firm and reliable, and shall be short, thick and straight.
2. When installing, please connect according to the installation diagram, where L1, L2 and L3 are phase lines, n is zero line, PE is ground wire, do not connect wrongly. After installation, close the automatic circuit breaker (fuse) switch.
3. It is recommended to connect fuses or automatic circuit breakers in series at the front end of SPD. Ensure to avoid fire caused by short circuit after deterioration of lightning arrester.
4. Remember that live working is not allowed. Power supply must be cut off before installation. Live working is strictly prohibited.
5. Grounding must be good and meet the requirements of relevant national lightning protection specifications
6. The equipment needs regular inspection and must be replaced immediately after deterioration.

FAQ 
Q: Are you a factory or a trade company?  
A: We are the factory. 

Q: Where are your products distributed?   
A: Our products are distributed all over the world, Main market are Europe, North America, the United Arab Emirates, Africa and so on. 

Q: Can I have a sample?    
A: Yes, but according to our company's policy, we provided free samples, while you should pay the freight fee; the sample can be delivered by TNT/DHL/UPS/FEDEX. 

Q: Which port is the nearest from you?   
A: Guangzhou port or Shenzhen Port or Hong Kong port.

Q: What's your lead time? 
A: Sample lead time: 3~5 working days. Mass production: usually 10~30days.
For big orders, honestly, it depends on the order quantity and designs. 

Q: When can I get the price? 
A: We usually quote within 24 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your email so that we will regard your inquiry as priority.
 
Q: Can you do the design for us? 
A: Yes, we have a professional team having rich experience in molding design, electrical system developing and manufacturing. Please just tell us your ideas and we will help you to carry out your ideas into a perfect artwork. You can pay for the molding fee and own the mold by yourself or we can cooperate on the molding. 

Q:How to pay?
A: We accept T/T, Paypal, Western union, L/C, Trade Assurance