5kV Megger (IR Tester)

China 5kV Megger (IR Tester), Find details about China Insulation Tester, Insulation Resistance Testers from 5kV Megger (IR Tester)

Model NO.
GD3126A
Weight
3.7kg
Power Source
AC220V
Test Voltage
250V, 500V, 1.0kV, 2.5kV, 5.0kV
Short-Circuit Current
Approx. 6mA
Accuracy class
Class 5.0
Resistance range
500GΩ-10TΩ
High voltage display error
±( 5%•Ux + 1d )
Withstand voltage
AC10.0kV 50Hz 1min (between test wire and case)
Trademark
HV Hipot
Transport Package
Carton or Wooden Case
Specification
ISO, SGS
Origin
Wuhan China
HS Code
9030332000
Model NO.
GD3126A
Weight
3.7kg
Power Source
AC220V
Test Voltage
250V, 500V, 1.0kV, 2.5kV, 5.0kV
Short-Circuit Current
Approx. 6mA
Accuracy class
Class 5.0
Resistance range
500GΩ-10TΩ
High voltage display error
±( 5%•Ux + 1d )
Withstand voltage
AC10.0kV 50Hz 1min (between test wire and case)
Trademark
HV Hipot
Transport Package
Carton or Wooden Case
Specification
ISO, SGS
Origin
Wuhan China
HS Code
9030332000
5kV Digital Automatic IRT Insulation Resistance Tester GD3126A


5kV Megger (IR Tester)
5kV Megger (IR Tester)
5kV Megger (IR Tester)




Application

 
This device can test insulation resistance (such as transformer, switchgear, lead, motor) of different modules in one system, to insulate and repair failure components.
It is important to ensure products quality and security of person and equipments during operation by insulation test of checking test object to ground or adjacent conductors insulation.
Before power on the system, using insulation test to verify if it is good to improve system performance. Insulation test is to find manufacturing process problems and equipment fault which can not be found before failure happened.In EU,this test is compulsory,even to civil system.
 

 
Features
 
1. With strong anti-interference ability.
2. Short-circuit current of test power is from 5-15mA, suitable for big capacity and big inductance test.
3. Broad testing range of resistance, from 0.5MΩ-200GΩ, more accurate reading and high resolution.
4. The voltage can be also adjusted from 0V to required voltage.
5. With timing function, convenient for recording absorption ratio and polarization index.



Technical Specifications
Test Voltage250 V,500V,1.0kV,2.5kV,5.0kV
Test Voltage accuracy±5%
Resistance RangeMax.500GΩ~10TΩ
Min.0.1MΩ
Accuracy Grade5.0
High Voltage Display Error±( 5%•Ux + 1d )
Leakage current range and error0.1nA~9.9mA    5%
Display range and error of absorption capacitance0.1pF~99μF    5%
Temperature measurement error±0.5ºC
Measurement error of air humidity±2%RH
Short circuit currentAbout 6mA
Voltage ripple<3%
Insulation resistance> 500 MΩ
PressureAC10.0kV 50Hz 1min
Power Supply12V Li-battery
Use time of full charge30 days 10times DAR & 5times PI daily test
Operating temperature and humidity 0ºC ~ + 40ºC   < 85%RH
Storage temperature and humidity- 20ºC ~ + 50ºC  < 90%RH
Size(mm)325(L)×250(W)×130(H)
Weightabout 3.7kg
measurement resistance error
Voltage250 V500 V1.0 kV2.5 kV5.0 kV
±( 3%·Rx + 1d )1GΩ2GΩ4GΩ10GΩ20GΩ
±( 5%·Rx + 1d )10GΩ20GΩ40GΩ0.1TΩ0.2TΩ
±( 10%·Rx + 2d )100GΩ200GΩ0.4TΩ1TΩ2 TΩ
±( 25%·Rx + 2d )500GΩ1TΩ2TΩ5TΩ10TΩ

5kV Megger (IR Tester)