AAC All Aluminum Bare Conductor

China AAC All Aluminum Bare Conductor, Find details about China AAC, Bare Conductor from AAC All Aluminum Bare Conductor

Model NO.
Bare conductor
Wire Core Material
Aluminum
Certification
ISO, CCC, BV, SGS
Model
Stranded
Standard
ASTM, BS, IEC, NFC, CSA
Advantages
High Quality, Competitive Price, Fast Response
Core No
7-91
Related Voltage
0.6/1kv, 8.7/15kv, 12-20kv, 21/35kv
Shipment Terms
Fob, CFR, CIF
Export Experience
Southeast Asia, Africa, Middle East
OEM/ODM
Yes
Delivery Time
15-30days
Sample
Free
Transport Package
Wooden Drum, Steel-Wooden Drum or as Requirement
Specification
10mm2-1500mm2
Origin
Henan, China
HS Code
7614900000
Model NO.
Bare conductor
Wire Core Material
Aluminum
Certification
ISO, CCC, BV, SGS
Model
Stranded
Standard
ASTM, BS, IEC, NFC, CSA
Advantages
High Quality, Competitive Price, Fast Response
Core No
7-91
Related Voltage
0.6/1kv, 8.7/15kv, 12-20kv, 21/35kv
Shipment Terms
Fob, CFR, CIF
Export Experience
Southeast Asia, Africa, Middle East
OEM/ODM
Yes
Delivery Time
15-30days
Sample
Free
Transport Package
Wooden Drum, Steel-Wooden Drum or as Requirement
Specification
10mm2-1500mm2
Origin
Henan, China
HS Code
7614900000
Applications
AAC are used in overhead power transmission and distribution lines with various grade voltages. Under the same weight,AAC is with higher DC resistance and lower cost than copper conductor. Aluminum is light and is easy to lay.

AAC All Aluminum Bare Conductor

Standard
 BASTM B231 B232, BS 215 , DIN 48201, CSA C49,NFC 34120


Specification

Stranded 1350 aluminum conductors shown in this section of data are classified, as follows: 
Class AA For bare conductors usually used in overhead lines.
Class A For conductors to be covered with weather-resistant materials and for bare conductors where greater flexibility is required.
Class B For conductors to be insulated with various materials and for conductors indicated under Class A where greater flexibility is required. 
Class C For conductors where greater flexibility is required

ASTM B231
Code wordSize of ConductorStranding and Wire DiameterOverall DiameterMax.D.C. Resistance at 20°CCode wordSize of ConductorStranding and Wire DiameterOverall DiameterMax.D.C. Resistance at 20°C
AWG or MCMmmmmohm/kmAWG or MCMmmmmohm/km
Peachbell67/1.5544.672.1692Verbena70037/3.49324.450.0813
Rose47/1.9615.891.3624Nasturtium715.561/2.7524.760.0795
Lris27/2.4747.420.8577Violet715.537/3.53324.740.0795
Pansey17/2.7768.330.6801Cattail75061/2.81725.350.0759
Poppy1/07/3.1199.360.539Petunia75037/3.61725.320.0759
Aster2/07/3.50310.510.4276Lilac79561/2.9026.110.0715
Phlox3/07/3.93211.80.339Arbutus79537/3.72426.060.0715
Oxlip4/07/4.41713.260.2688Snapdragon90061/3.08627.780.0632
Valerian25019/2.91314.570.2275Cockscomb90037/3.96227.730.0632
Sneezewort2507/4.8014.40.2275Goldenrod95461/3.17728.60.0596
Laurel266.819/3.0115.050.2133Magnolia95437/4.07928.550.0596
Daisy266.87/4.9614.90.2133Camellia100061/3.25129.360.0569
Peony30019/3.19315.970.1896Hawkweed100037/4.17629.230.0569
Tulip336.419/3.38116.910.1691Larkspur1033.561/3.30729.760.055
Daffodil35019/3.44717.240.1625Bluebell1033.537/4.24429.720.055
Canna397.519/3.67318.360.1431Marigold111361/3.43230.890.0511
Goldentuft45019/3.90919.550.1264Hawthorn1192.561/3.55131.050.0477
Syringa47737/2.88220.190.1193Narcissus127261/3.66833.020.0477
Cosmos47719/4.02320.120.1193Columbine1351.561/3.7834.010.0421
Hyacinth50037/2.95120.650.1138Carnation143161/3.8935.030.0398
Zinnia50019/4.1220.60.1138Gladiolus1510.561/4.0035.090.0376
Dahlia556.519/4.34621.730.1022Coreopsis159061/4.09936.510.03568
Mistletoe556.537/3.11421.790.1022Jessamine175061/4.30238.720.0325
Meadowsweet60037/3.23322.630.0948Cowslip200091/3.7641.40.02866
Orchid63637/3.3323.310.0894Lupine250091/4.2146.30.023
Heuchera65037/3.36623.560.0875Trillium3000127/3.9050.750.0192
Flag70061/2.7224.480.0813Bluebonnet3500127/4.2154.80.01653

BS215
Code nameNominal aluminum areaStranding and wire diameterSectional areaOverall diameterLinear massMax. DC resistance at 20ºCRated strengthFinal modulus of elasticityCoefficient of linear expansion
 mm2mmmm2mmkg/kmΩ/kmdaNhbar/ºC
Midge227/2.0623.336.1863.81.227399590023.0x10-6
Aphis253/3.3526.407.2731.081411590023.0x10-6
Gnat257/2.2126.86.6731.066459590023.0x10-6
Weevil303/3.6631.67.9860.9082486590023.0x10-6
Mosquito357/2.5937.07.81010.7762603590023.0x10-6
Ladybird407/2.7942.88.41170.6689687590023.0x10-6
Ant507/3.1052.839.301450.5419828590023.0x10-6
Fly607/3.4063.5510.201740.4505990590023.0x10-6
Bluebottle707/3.6673.711.02020.38811134590023.0x10-6
Earwig757/3.7878.511.42150.36441194590023.0x10-6
Grasshopper807/3.9184.111.72300.34061278590023.0x10-6
Clegg907/4.1795.612.52620.29941453590023.0x10-6
Wasp1007/4.39106.013.172900.27021600590023.0x10-6
Beetle10019/2.67106.013.42930.27041742560023.0x10-6
Bee1257/4.90132.014.73610.21691944560023.0x10-6
Cricket1507/5.36157.916.14320.18182385560023.0x10-6
Hornet15019/3.25157.616.254340.18252570560023.0x10-6
Caterpillar17519/3.5318617.75120.15472863560023.0x10-6
Chafer20019/3.78213.218.95870.13493240560023.0x10-6
Spider22519/3.99236.920.06520.12113601560023.0x10-6
Cockroach25019/4.22265.721.107310.10834040560023.0x10-6
Butterfly30019/4.65322.723.258880.089164875560023.0x10-6
Moth35019/5.00373.225.010270.077115637560023.0x10-6
Drone35037/3.58373.325.110290.077415745560023.0x10-6
Locust40019/5.36428.526.811790.067106473560023.0x10-6
Centipede40037/3.78415.226.4611450.069446310560023.0x10-6
Maybug45037/4.09486.928.613420.059317401560023.0x10-6
Scorpion50037/4.27529.529.914600.054417998560023.0x10-6
Cicada60037/4.65628.632.617330.045889495560023.0x10-6
Tarantula75037/5.23794.636.621910.0362712010560023.0x10-6

DIN 48201
SizeCalculated areaStranding and wire diameterOverall diameterLinear massRated strengthMax. DC resistance at 20ºC
mm2mm2mmmmkg/kmdaNΩ/km
1615.897/1.705.1442901.8018
2524.257/2.106.3674251.1808
3534.367/2.507.5945850.8332
5049.487/3.009.01358100.5786
5048.3619/1.809.01338600.5950
7065.8219/2.1010.518111500.4371
9593.2719/2.5012.525615950.3084
120117.0019/2.8014.032219100.2469
150147.1037/2.2515.240625700.1960
185181.6037/2.5017.550131050.1587
240242.5461/2.2520.267040150.1191
300299.4361/2.5022.582748500.09650
400400.1461/2.8926.0110561900.07221
500499.8361/3.2329.1138176000.05781
625626.2091/2.9632.6173396900.04625
800802.1091/3.3536.82219120550.03611
1000999.7191/3.7441.12766148450.02897

IEC 61089
Cross SectionNumber of Stranding WiresDiameterLinear MassRated StrengthMax.D.C. Resistance at 20ºC
WiresConductor
mm2 -mmmmkg/kmkNΩ/km
1071.354.0527.41.952.8633
1671.715.1243.83.041.7896
2572.136.468.44.51.1453
4072.78.09109.46.80.7158
6373.3910.2172.310.390.4545
100192.5912.9274.8170.2877
125192.8914.5343.621.250.2302
160193.2716.4439.826.40.1798
200193.6618.3549.7320.1439
250194.0920.5687.1400.1151
315373.2923867.951.970.0916
400373.71261102640.0721
450373.9427.51239.8720.0641
500374.15291377.6800.0577
560374.3930.71542.989.60.0515
630613.6332.61738.3100.080.0458
710613.8534.61959.1113.60.0407
800614.0936.82207.41280.0361
900614.33392483.31440.0321
1000614.5741.12759.21600.0289
1120913.9643.53093.5179.20.0258
1250914.18463452.62000.0231
1400914.4348.73866.92240.0207
1500914.5850.44143.12400.0193

Refered Standards
(1). IEC 61089: Round wire concentric lay overhead electrical stranded conductors
(2). DIN 48 201-5: All Aluminium Conductors
(3). BS 215-1: Aluminium strander conductors
(4). ASTM B231: Stranded Specification for Concentric-Lay-Stranded Aluminium 1350 Conductors
(5). AS 1531: Conductors-Bare overhead-Aluminium and aluminium alloy
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied. 

Bare Conductor Types
(1) all aluminum conductor (AAC)
(2) all aluminum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminum conductor aluminum clad steel reinforced(ACSR/AW)
(6) rear earth aluminum conductor steel reinforced(ACSR/RE)
(7) aluminum conductor aluminum alloy reinforced(ACAR)
(8) aluminum conductor steel supported (ACSS)
(9) aluminum conductor carbon core(ACCC)

About Us

Henan Kingyear Aluminum Industrial Co., Ltd was founded in 2006, located in Gongyi industry area of Henan Province. Our company consists of 3 main subsidiaries, business specialized in develop, manufacture and distribution of Aluminum products. Our factories zone occupies more than 1200,000 square meters and the employees' number has exceeded 200.
We, Kingyear, dedicate ourselves to be a manufacturer of providing comprehensive solutions and customized services to help our customer to solve their problems and improve their profit.
We have a professional sales team with each of them has engaged in this job for 10 years, so that we can provide the comprehensive and professional technology for you.
With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win business relationship!

Our mainly products as follow: 
1--pvc insulated electric wire whatever copper conductor,aluminum conductor, CCA(copper clad aluminum), CCS(copper clad steel).
2--pvc and xlpe insulated power cable with or without armor upto 35kv.
3--rubber cable like welding cable, mine cable, EPR cable and so on.
4--aerial bundled cable(ABC cable) up to 10kv.
5--bare conductor like AAC, AAAC, ACSR, ACAR, ACSR/AW, aluminum clad steel wire, galvanized steel wire, PC steel wire and so on.
AAC All Aluminum Bare Conductor

Packing & Delivery
Packing Details  : Packing in wooden drum, iron-wooden drum or as customer's requirement.
Delivery Details : 15-25 days after place an order.
AAC All Aluminum Bare Conductor
Certification
We have obtained CCC, ISO9001, ISO14001 certificates, passed the SGS and BV test.

Our Service:
1.10 years production experience and 10 years export experience .
2.Products certification :ISO,SGS,CE,BV
3.OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback,Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7.Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.
AAC All Aluminum Bare Conductor

FAQ
Q:I didn't find the cable which I need in this page?
A:If you didn't find the species of cables you need, please contact us directly, we will reply you quickly.
Q:What's your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 1000 meters.
Q:What's your delivery time?
A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us, we will send you the free sample, but the freight charge should be paid.