SECTION 1:DESCRIPTION***********************************************************
KP1006B-7T Generation 3th overhead 2-fan ionizing air blower is an anti-static device developed and produced by Capal Company to eliminate static electricity on the surface of objects.
KP1006B-7T Generation 3th overhead 2-fan ionizing air blower can generate a large amount of airflow with positive and negative charges, which can neutralize the charge on the object. When the surface of the object is negatively charged, it will attract the positive charge in the airflow. When the surface of the object is positively charged, it will attract the negative charge in the airflow, so that the static electricity on the surface of the object is neutralized and eliminated. The purpose of static electricity.
KP1006B-7T Generation 3th overhead 2-fan ionizing air blower is provided with wind power by two cross-flow fans, and the wind power can be adjusted within a large range by the speed control switch.
KP1006B-7T Generation 3th overhead 2-fan ionizing air blower is widely used in industries such as pharmaceutical manufacturing and assembly, electronic production and packaging, LED assembly line, and micro-measurement devices.

SECTION 2:FEATURES***************************************************************
1.Quickly eliminate static electricity.
2.Ion air flow covers a large area.
3.There is an ionization indicator.
4.There is a special ion emission needle cleaner.
5.The use of hanging installation can save space.
6.The fan has a good grounding protection function.


SECTION 3:SPECIFICATIONS********************************************************
Input voltage220V/50Hz or 110V/60Hz
Output voltageAC 5.6KV
Power    53W
Ion balance≤|±10V|(distance 300mm)
Discharge time ≤2S(distance 300mm)
Working distance600×1200mm
Working temperature     0ºC-50ºC
Working humidity<75%
Fan air volume ≤5.1m3/min90-380CFM
Noise49-70dB
Ozone concentration≤ 0.03 ppm  (distance150mm)
Gross weight  12kg
Dimension1000mm(L)*205mm(W)*190mm(H)
Surface treamentElectrostic painting

SECTION 4:TEST  RESULT**********************************************************
Testing condition
Humidity:≤60%         Testing voltage:1KV-100V        Temperature:22ºC
Distance300mm600mm
Decay timePositive1.1s1.7s
Negative1.2s1.8s
Offset voltagePositive+6v+10v
Negative-7v-9v

* The test result by ME268A comprehensive electrostatic tester shall prevail.
* Test according to IEC - 61340-5-1 A 6.
* Test data may change with the surrounding temperature and humidity.

Electronic industry

In addition to electrostatic equipment to solve the electrostatic hazards of the optoelectronic industry, electronics industry, semiconductor industry, etc., why are the optoelectronic industry, electronics industry, semiconductor industry, etc. all the killer to static TV? Why do they treat electrostatic protection as a major project? It is because of the harm caused by static electricity in industrial production. The main points are as follows:
 
1) Cause malfunction or malfunction of electronic equipment, causing electromagnetic interference.
 
2) Break down integrated circuits and precision electronic components, or promote the aging of components, reducing the production yield.
 
3) High-voltage electrostatic discharge causes electric shock, endangering personal safety.
 
4) Electronics industry: absorb dust, cause pollution of integrated circuits and semiconductor components, and greatly reduce the yield.
Kapper Generation 3th Overhead 2-Fan Ionizing Air Blower Anti Static BlowerKapper Generation 3th Overhead 2-Fan Ionizing Air Blower Anti Static Blower

About Kapper

KAPPER specializes in the production of ionnizing  blowers, ionizing air guns, ionizing air bar, ionizing air snakes and other static elimination equipment manufacturers, and the pioneer of industrial static control. Since its inception in 2006, it has always been dedicated to industrial static electricity. Control: Professional R&D and manufacturing of ionizing air nozzles, ionizing fans, ionizing rods, ionizing snakes, ionizing air guns, electrostatic testers and other static elimination equipment and related products. It has provided high-quality industrial static control and advanced and unique technical solutions for many famous manufacturers across the worldwide. It is a comprehensive enterprise specializing in the research and development, production, sales and agency of dust-free purification products and anti-static products.

Kapper Generation 3th Overhead 2-Fan Ionizing Air Blower Anti Static BlowerKapper Generation 3th Overhead 2-Fan Ionizing Air Blower Anti Static Blower
Kapper Generation 3th Overhead 2-Fan Ionizing Air Blower Anti Static Blower