China Environment Climate Control System for Poultry Farming Screen Touch Type, Find details about China Environment Controller, Control System from Environment Climate Control System for Poultry Farming Screen Touch Type
project | Standard | |
Power Supply | Voltage and frequency Allowable fluctuation | Single phase 220V 50/60HZ Voltage: +-10% frequency: +-5% |
control | control mode | Relay output; 0-10V analog output |
Signal input | Single bus digital I/O sensor: 0-5 V analog input, 10K NTC sensor | |
Frequency conversion signal | 0-10V analog control, optional turn off switch, control frequency converter start stop | |
Relay control | It can control 0-4 way exhaust fan, high and low temperature alarm, cooling water pump | |
control mode | See the third chapter function list | |
display | The left digital tube shows the temperature, and the right digital tube shows the variable speed (HZ) Go to settings, display the current parameter on the left, and the number on the right side corresponding to the parameter. | |
Environmental Science | Installation site | Indoor installation, non corrosive gas and direct sunlight |
Temperature humidity | * * 90%, 10 DEG C, 40 C, 20% RH | |
Vibration | 20HZ below is less than 0.5g | |
Storage temperature | -20ºC~60ºC | |
Installation method | Wall hanging | |
Ln911 livestock and poultry environmental control system
Ln911 environmental controller has 11 relay outputs, which can control 6 groups of constant speed wind turbines and 2 groups of speed regulating wind turbines.It is mainly used for pig users.
SPECIFICATIONS
Temperature sensors * 4
Humidity Sensor * 1
Heater * 1
Cool Pad * 1
Alarm * 1
Fan Groups * 6
Air Inlet * 1
Variable Speed Fan * 2
T607 |
Ø Designed for broiler house Ø 8 stages: 1alarm output, 1group of heater, 5 groups of fan, 1 group of cooling |
T610 |
Ø Normally use for broiler house Ø 10 stages: 1 alarm out put, 1group of heating, 5 groups of fan, 1 group of cooling, 1group of air inlet, 1 group of variable fan |
T616 |
Ø Normally for breeder house Ø 12 stages: 1 alarm output, 1 group of heating, 7 group of fan, 1 group of cooling, 1 group of air inlet, 1 group of curtain |
AC2000 |
Ø LCD and keyboard can display 20 characters to use for communication between computers und users. The keyboard is used to enter data and compile control procedures Ø 20 built-in replays for production equipment control Ø Poultry load, up to three heating sections can be precise local control, you can also install an integrated humidity and static pressure sensor, a temperature sensor 6 for data acquisition Ø AC2000 can be connected with the computer for data exchange |
AC2000+ |
Ø 12/20 output replays analong output Ø Monitors and controls temperature, humidity, pressure, lighting, water and feed consumption, and poultry weight Ø Digital inputs for water, feed counters and wind direction Ø Optional static pressure sensor on board Ø Computer control is available |