Earthleakage Circuit Breaker (ELCB) of Rdl20-160-4300 (63-160A) 4p

China Earthleakage Circuit Breaker (ELCB) of Rdl20-160-4300 (63-160A) 4p, Find details about China Electronic Type Circuit Breaker, Moulded Case Circuit Breaker from Earthleakage Circuit Breaker (ELCB) of Rdl20-160-4300 (63-160A) 4p

Model NO.
RDL20
Poles Number
4
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Certification
ISO9001-2000, CE, CB, CCC
Operate Type
Electronic Type
Frequency
50Hz
Rated Current a
From 16A to 630A
Pole
4p
Rated Operate voltage V
380V
Accessory
Selectable
Ultimate Short-Circuit Breaking Capacity
12ka, 15ka, 30ka, (Selectable)
Trademark
PEOPLE
Transport Package
Craton
Specification
CCC, CE, CB
Origin
China
HS Code
8536200000
Model NO.
RDL20
Poles Number
4
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Certification
ISO9001-2000, CE, CB, CCC
Operate Type
Electronic Type
Frequency
50Hz
Rated Current a
From 16A to 630A
Pole
4p
Rated Operate voltage V
380V
Accessory
Selectable
Ultimate Short-Circuit Breaking Capacity
12ka, 15ka, 30ka, (Selectable)
Trademark
PEOPLE
Transport Package
Craton
Specification
CCC, CE, CB
Origin
China
HS Code
8536200000
Application
RDL20 series Earthleakage circuit breaker, is applied to circuit of AC50Hz,rated operate voltage 380V,rated current from 16A to 630V,as protection against electric leakage of circuit and equipments.And it also can previde protection against the fire danger which is caused by equipment insulation damage.And this product also protect circuit agaisnt overload and short-circuit,and circuit unfrequently transfer.
This product conforms to the standards of IEC60947-2 and GB14048.2.
Normal operational conditions and installation conditions
3.1 Temperater: no higher than +40ºC,and no lower than -5ºC,and the day average temperature no higher than +35ºC.
3.2 Altitude: no higher than 2000m
3.3 The relative humidity: no more than 50%,when temperature is +40ºC.The product can withstand higher humidity under lower temperature,for instance,when it at +20ºC,the production can withstand 90% relative humidity.
The condensation that happened because of temperature changes should be taken care.
And Installation location should have no exploresion danger, and no gas and conductive dust which can cause corrosion and insulation damage.
3.4 Class of pollution: 3 Calss
3.5 Installation type:III
3.6 Installation Location: Vertical plane,Maximum install inclined angle: 5°
3.7 External magneticfield of installation location should be exceed than 5 times of earth magnetic field.
3.8 Installation electromagnetic environment:B type
For more details and information,please contact us with no hesitate
 
Or visit our website: http://chinapeople.en.made-in-china.com
Main technical parameter,as following:
ModelRated current In ARated Ultimate short-circuit breaking capacity Icu kARated residual action current IΔn mARated residual short-circuit making capacity IΔm kAMax breaking time sInstantaneous current setting valueArc distance mm
RDL20-16050,63,80,100,125,16012100,200,300
100\200\300(adjustable)
3Fast type≤0.1,
Delay tyoe0.4
10In12In100
RDL20-250100,125,160,180,200,25015100,200,300
100\200\300(adjustable)
4150
RDL20-400200,250,315,350,40030200,300,500
200\300\500(adjustable)
5200
RDL20-630400,500,63030200,300,500
200\300\500(adjustable)
5200