2MHz Bandwidth 2000A Current Clamp on CT

China 2MHz Bandwidth 2000A Current Clamp on CT, Find details about China Clamp on CT, Clamp CT from 2MHz Bandwidth 2000A Current Clamp on CT

Model NO.
S120
IP Rating
IP30
Certification
ISO
Customized
Non-Customized
Product Name
2000A Current Clamp on CT
Ratio
2000:1
Current Range
0-2000A, 0-3000A
Color
Red & Grey
Applications
Instrument Measurement
Weight
1.2kg
Output Signal
0-2V, 0-2A, 0-5V, 0-10V
Standard
IEC/En61010-2-032, IEC61869-2
Trademark
GFUVE
Transport Package
Standard Export Box
Specification
S120 2000a/2v class 0.1
Origin
Beijing China
Model NO.
S120
IP Rating
IP30
Certification
ISO
Customized
Non-Customized
Product Name
2000A Current Clamp on CT
Ratio
2000:1
Current Range
0-2000A, 0-3000A
Color
Red & Grey
Applications
Instrument Measurement
Weight
1.2kg
Output Signal
0-2V, 0-2A, 0-5V, 0-10V
Standard
IEC/En61010-2-032, IEC61869-2
Trademark
GFUVE
Transport Package
Standard Export Box
Specification
S120 2000a/2v class 0.1
Origin
Beijing China
Package size per unit product
33.00cm * 30.00cm * 30.00cm
Gross weight per unit product
6.500kg
2MHZ BANDWIDTH 2000A CURRENT CLAMP ON CT S120 GFUVE

The S120 clamp on ct is a general purpose 2000A AC Clamp current probe transformer designed for use with DMMs, cable fault analysis and loggers instruments that have a current input. It has a 1000:1 or 2000:1 ratio and output of 1mA per amp or 1mV per amp measured in the jaw. The S120 has an integral 2.5m or 5m lead terminated. The rounded jaw design on this clamp probe makes it well-suited for cable fault analysis applications where high accuracy and low phase shift and wide frequency.
GFUVE® manufactures the most complete line of current probes in the world. Whether you need to measure from a few mA to several thousand Amps, we have the probe you need. Our probes are designed to work in tight places and to clamp around large bus bars. We offer a variety of output options and terminations for recorders, data loggers, oscilloscopes, DMMs and other instruments.

Our line of AC probes is designed to provide long term service and measurement results. The wide variety of models to choose from facilitates measurement from a few mA to several thousand Amps. They are designed to provide accurate true RMS measurements with low phase shift error in power applications. They are designed to work in tight places and to clamp around large bus bars. Several output ranges and terminations are available to interface with any instrument.

The round jaw design on the S120 Series clamp on cts along with the high content nickel metal core makes them well suited for power quality applications where high accuracy and low phase shift along with wide frequency are important. Measurement range is 1mA to 3000A.

 

APPLICATIONS

  • Power quality analyzer(PQA)
  • power and harmonic meters
  • Energy meter calibrator
  • Cable Fault Analysis
  • Measuring around cable bundles
  • Power load monitoring
  • Earth resistance meter
  • Large industrial loads
 

FEATURES

  • Measurement range of 10mA to 2000A AC
  • Improved ergonomic design & easy operation
  • High content nickel metal permalloy core
  • Frequency 10-2MHz
  • Holding wire diameter: φ120mm
  • Conforms to EN 61010, 600V CAT III
  • Transformation ratio: 1000:1, 2000:5
  • Low phase shift for power measurement
  • Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters
  • UL, CE mark
 

PARAMETERS

Electrical parameters
Ratio1000: 1 or 2000:5 (customized)
Accuracy class0.1%, 0.2%, 0.5%
Primary current0 - 2000A AC
Secondary current0-2A or 0 - 5A AC (customized)
Secondary voltage0-2V AC (customized)
Max. Cont. Input current2400A
Over voltage categoryCAT III 600V
Output signal (AC current)500mA, 1A,2A,5A  AC at nominal input current
Output signal (AC voltage)1V, 2V, 10V  AC at nominal input current
Frequency range10Hz-2MHz
Dielectric strength3KV 50Hz/60Hz  at 1 minute
Temperature range-40°C to +55°C
Output2.5 meter cable with D01 connector or BNC
Max. voltage not insulated conductors600 V
StandardEN 61010-1, EN 61010-2-032, IEC60044-1, IEC61869-2
Installationclamp type
Output modelead output(2.5m,  5m or 10m)
Accuracy (2000A Range)
0-10A≤0.5%
10-100≤0.2%
100-2000A≤0.1%
Phase Shift(2000A Range)
0-10A≤0.5°
10-100≤0.2°
100-2000A≤0.1°
Mechanical parameters
Dimensions (L x W x H) (mm)178 x 290 x 30
Weight (g)1200
Holding wire diameter (mm)φ120
Max. jaw opening (mm)120
Jaw colorRed & Grey
MaterialPC+ABS, UL94 V0

PHOTO

2MHz Bandwidth 2000A Current Clamp on CT